Cable Pull Switches

Image Part Number Description / PDF Quantity Rfq
ER1022-042MELR

ER1022-042MELR

Omron Automation & Safety Services

ER1022-042MELR, 4N/C+2N/O, M20

3

ER1022-042NELR

ER1022-042NELR

Omron Automation & Safety Services

SWITCH LIMIT 4NC 2NO 6A 120V

4

ER5018-021N

ER5018-021N

Omron Automation & Safety Services

SWITCH LIMIT 2NC 1NO 6A 120V

0

ER6022-021NEL

ER6022-021NEL

Omron Automation & Safety Services

SWITCH LIMIT 2NC 1NO 6A 120V

1

ER1022-042NELL

ER1022-042NELL

Omron Automation & Safety Services

SWITCH LIMIT 4NC 2NO 6A 120V

2

ER5018-021M

ER5018-021M

Omron Automation & Safety Services

ER5018-021M, 2N/C+1N/O, M20

3

ER6022-022NEL

ER6022-022NEL

Omron Automation & Safety Services

SWITCH LIMIT 2NC 2NO 6A 120V

2

ER5018-030NE

ER5018-030NE

Omron Automation & Safety Services

ER5018-030NE, 3N/C, 1/2" NPT, E

0

ER6022-021M

ER6022-021M

Omron Automation & Safety Services

ER6022-021M, 2N/C+1N/O, M20

1

ER5018-021NE

ER5018-021NE

Omron Automation & Safety Services

SWITCH LIMIT 2NC 1NO 6A 120V

7

ER6022-021NE

ER6022-021NE

Omron Automation & Safety Services

SWITCH LIMIT 2NC 1NO 6A 120V

0

ER6022-021N

ER6022-021N

Omron Automation & Safety Services

SWITCH LIMIT 2NC 1NO 6A 120V

2

ER1032-042NEL

ER1032-042NEL

Omron Automation & Safety Services

SWITCH LIMIT 4NC 2NO 6A 120V

6

ER1032-042MELAC

ER1032-042MELAC

Omron Automation & Safety Services

ER1032-042MELAC, 4N/C+2N/O, M20

0

ER6022-022NELAC

ER6022-022NELAC

Omron Automation & Safety Services

ER6022-022NELAC 2 N/C+2 N/O 1/2"

0

XER1032-011C3

XER1032-011C3

Omron Automation & Safety Services

XER1032-011C3, 1N/C+1N/O, EX BLO

0

ER6022-030ME

ER6022-030ME

Omron Automation & Safety Services

ER6022-030ME, 3N/C, M20, E STOP,

0

ER6022-030MEL

ER6022-030MEL

Omron Automation & Safety Services

ER6022-030MEL, 3N/C, M20, E STOP

0

ER6022-022MLSS

ER6022-022MLSS

Omron Automation & Safety Services

ER6022-022MLSS, 2N/C+2N/O, M20

0

ER6022-031N

ER6022-031N

Omron Automation & Safety Services

ER6022-031N, 3N/C+1N/O, 1/2" NPT

0

Cable Pull Switches

1. Overview

Cable pull switches are manually operated electrical control devices activated by pulling a cable or rope. They serve as emergency stop systems or process control interfaces in industrial and commercial equipment. These switches convert mechanical cable movement into electrical signal changes, playing critical roles in safety systems and machine control circuits.

2. Major Types and Functional Classification

TypeFunction FeaturesApplication Examples
Mechanical Cable Pull SwitchDirect mechanical actuation with physical contactConveyor belt emergency stop
Magnetic Cable Pull SwitchContactless operation with magnetic field detectionAutomotive production lines
Limit Switch with Cable ActuatorPrecise position detection with mechanical linkageIndustrial gate control systems
Multi-directional Pull Switch360 rotational activation capabilityMaterial handling equipment

3. Structure and Components

Typical construction includes: - Reinforced polymer/metal housing - Stainless steel cable with synthetic coating - Internal actuator mechanism (cam, spring, or magnet) - Electrical contact block (silver alloy contacts) - Cable anchor point with tension adjustment - IP65+ environmental sealing

4. Key Technical Specifications

ParameterTypical RangeImportance
Rated Current1-10ADetermines load handling capacity
Operating Voltage24VDC-230VACSystem compatibility factor
IP RatingIP65-IP68Environmental protection level
Cable Tension30-150NActivation force requirement
Electrical Life100,000-1,000,000 cyclesLong-term reliability indicator
Ambient Temp-20 C to +85 COperational temperature range

5. Application Areas

Primary industries include: - Manufacturing automation - Material handling systems - Agricultural machinery - Mining equipment - Commercial gym equipment - Packaging machinery

Typical equipment integration: Emergency stop systems on conveyor belts Safety interlocks in robotic workcells Process control in assembly lines

6. Leading Manufacturers and Products

ManufacturerKey Product SeriesTechnical Highlights
Schneider ElectricXPS-FCIP67 rating, 10A contacts
OmronWLCA2Non-contact magnetic sensing
Siemens3SE5Adjustable tension mechanism
AlbrightSWPCorrosion-resistant marine grade

7. Selection Recommendations

Key consideration factors: - Environmental conditions (temperature, moisture, chemicals) - Required actuation force vs operator capability - Electrical interface compatibility - MTBF (Mean Time Between Failure) ratings - Industry-specific certifications (CE, UL, ISO) - Cable length and routing constraints - Maintenance accessibility

8. Industry Trends

Current development directions: - Integration with IoT-enabled predictive maintenance - Miniaturization while maintaining IP ratings - Wireless signal transmission options - Enhanced corrosion resistance materials - Multi-function switches with position feedback - Increased adoption in AGV (Automated Guided Vehicle) systems