Static Control Grounding Cords, Straps

Image Part Number Description / PDF Quantity Rfq
AMWS121M

AMWS121M

SCS

ADJ METAL WRIST BAND/12' CORD

86

WB2643

WB2643

Transforming Technologies

WRIST STRAP SET, BLACK, 12', 4MM

4341

3048

3048

SCS

GROUNDING SYS DUAL W/15' CORD

20140

19905

19905

EMIT

WRIST STRAP, DUAL-WIRE, MAGSNAP

24

2360

2360

SCS

COILED CORD DUAL COND GND 5'

909

19857

19857

EMIT

WRISTSTRAP DUAL ASSY MTL EXP 4MM

0

066-0002

066-0002

E S D Control Centre Ltd.

Fabric ESD Wrst Strp

452

23600

23600

EMIT

CRD CL WSCRP ECON 1M 6' 4MM

0

067-0038

067-0038

E S D Control Centre Ltd.

Strght Gnd Cord Mat/Flr Crd-10ft

100

CC9037

CC9037

Transforming Technologies

6' COIL CORD, BLACK, 4MM

3677

19868

19868

EMIT

COIL CORD DUAL WIRE 7MM 6'

0

CC0038

CC0038

Transforming Technologies

6' COIL CORD, BLACK, 7MM

1686

2369

2369

SCS

WRIST STRAP 5' COIL

1777

WB2695P20

WB2695P20

Transforming Technologies

20', DUAL 4MM, PARKING STATION

20

2271

2271

SCS

WRIST STRAP - HIGH LAND

0

WB4037

WB4037

Transforming Technologies

6', 4MM MACHINED POST

50

09230

09230

EMIT

WRISTBAND, JEWEL, ADJ METAL, WHI

61

09840

09840

EMIT

CORD, COMMON GROUND, DUAL-WIRE A

10

19851

19851

EMIT

WRIST STRAP DUAL ASSY 12' CORD

0

4650

4650

SCS

WRIST BAND 4MM STUD BLUE CORD 5'

102

Static Control Grounding Cords, Straps

1. Overview

Static control grounding cords and straps are critical components in electrostatic discharge (ESD) protection systems. These devices safely dissipate static electricity generated by human contact or equipment operation, preventing damage to sensitive electronic components. With the miniaturization of semiconductor devices and increasing demands for cleanroom environments, proper grounding solutions have become essential in maintaining product reliability across industries such as electronics manufacturing, aerospace, and medical device production.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Wrist StrapsSingle-wire/dual-wire configurations with 1M resistance, 99.9% conductivity retentionPCB assembly lines, semiconductor wafer handling
Coiled CordsRetractable design (3-12ft extended length), 10^6-10^9 surface resistanceTest equipment stations, cleanroom workbenches
Toe GroundersConductive elastomer interface, 250-750 contact resistanceESD flooring systems, automated material handling
Grounding AdaptersMulti-port banana jack connectors, 25A current ratingCalibration labs, precision measurement equipment

3. Structural Composition

Typical wrist strap assembly includes:

  • Conductive elastomer or carbon-loaded polymer contact surface
  • Knitted elastic fabric with embedded stainless steel fibers
  • Quick-disconnect (QD) interface with gold-plated contacts
  • Coaxial grounding cable (20AWG inner conductor, 10^9 /cm insulation)
  • Earth bond monitoring circuitry (for dual-wire systems)

Cord construction features braided copper conductors with polyurethane jackets meeting UL 1572 specifications.

4. Key Technical Parameters

ParameterValue RangeSignificance
Resistance Tolerance 5% to 10%Ensures controlled discharge rate
Breakaway Strength2.3-4.5kgfPersonnel safety under tension
Operating Temperature-20 C to +70 CEnvironmental stability
Dielectric Strength2500VAC/minuteInsulation reliability
Service Life2000+ connection cyclesCost-effectiveness metrics

5. Application Fields

Primary industries include:

  • Semiconductor manufacturing (photolithography equipment, wafer probers)
  • Electronics assembly (SMT pick-and-place machines, BGA rework stations)
  • Aerospace avionics (flight control system integration)
  • Pharmaceutical cleanrooms (tablet coating machines, isolators)
  • Data centers (server rack maintenance, fiber optic handling)

6. Leading Manufacturers

ManufacturerProduct LineKey Features
Desco IndustriesOmega Wrist Strap SystemDual-path monitoring, 10-year warranty
3MESD Pro Grounding SystemNano-carbon fiber integration
AlphaMetrixCleanroom Cord SetNon-particle shedding design
Simco-IonSmartGround SolutionReal-time resistance monitoring

7. Selection Guidelines

Key considerations:

  1. Environmental factors: Humidity range (10-90% RH), chemical exposure
  2. Human factors: Ergonomic design for 8-hour shifts, skin contact materials
  3. Compliance requirements: IEC 61340-5-1, ANSI/ESD S20.20 standards
  4. System integration: Compatibility with existing ESD flooring and workstations
  5. Total cost analysis: Balance between initial cost and mean time between failures (MTBF)

Case Study: In automotive sensor manufacturing, implementing dual-wire wrist straps reduced device failure rates from 320ppm to 15ppm.

8. Industry Trends

Current development directions include:

  • Smart grounding systems with IoT-enabled resistance monitoring
  • Nano-coated textiles for improved durability in Class 10 cleanrooms
  • Integrated biometric authentication for access-controlled ESD zones
  • Self-healing polymer materials for extended service life
  • AI-driven predictive maintenance algorithms for ESD infrastructure
RFQ BOM Call Skype Email
Top