Temperature Sensors - Thermostats - Mechanical

Image Part Number Description / PDF Quantity Rfq
66F065-0151

66F065-0151

Sensata Technologies – Airpax

THERMOSTAT 65DEG C SPST-NO 8DIP

0

66F055-0463

66F055-0463

Sensata Technologies – Airpax

THERMOSTAT 55DEG C SPST-NO 8DIP

0

66L080-0502

66L080-0502

Sensata Technologies – Airpax

THERMOSTAT 80DEG C SPST-NC 8DIP

0

67L040-0401

67L040-0401

Sensata Technologies – Airpax

THERMOSTAT 40DEG C NC TO220-2

0

66L120-0197

66L120-0197

Sensata Technologies – Airpax

THERMOSTAT 120DEG C SPST-NC 8DIP

0

66F065-0480

66F065-0480

Sensata Technologies – Airpax

THERMOSTAT 65DEG C SPST-NO 8DIP

0

66F050-0194

66F050-0194

Sensata Technologies – Airpax

THERMOSTAT 50DEG C SPST-NO 8DIP

0

67L070-0428

67L070-0428

Sensata Technologies – Airpax

THERMOSTAT 70DEG C NC TO220-2

0

66L045-0313

66L045-0313

Sensata Technologies – Airpax

THERMOSTAT 45DEG C SPST-NC 8DIP

0

66F080-0279

66F080-0279

Sensata Technologies – Airpax

THERMOSTAT 80DEG C SPST-NO 8DIP

0

67L115-0377

67L115-0377

Sensata Technologies – Airpax

THERMOSTAT 115DEG C NC TO220-2

0

67L085-0251

67L085-0251

Sensata Technologies – Airpax

THERMOSTAT 85DEG C NC TO220-2

0

66F040-0177

66F040-0177

Sensata Technologies – Airpax

THERMOSTAT 40DEG C SPST-NO 8DIP

0

67L115-0349

67L115-0349

Sensata Technologies – Airpax

THERMOSTAT 115DEG C NC TO220-2

0

66F060-0128

66F060-0128

Sensata Technologies – Airpax

THERMOSTAT 60DEG C SPST-NO 8DIP

0

66L070-0301

66L070-0301

Sensata Technologies – Airpax

THERMOSTAT 70DEG C SPST-NC 8DIP

0

66F090-0423

66F090-0423

Sensata Technologies – Airpax

THERMOSTAT 90DEG C SPST-NO 8DIP

0

67L125-0288

67L125-0288

Sensata Technologies – Airpax

THERMOSTAT 125DEG C NC TO220-2

0

67L085-0431

67L085-0431

Sensata Technologies – Airpax

THERMOSTAT 85DEG C NC TO220-2

0

67L118-0184

67L118-0184

Sensata Technologies – Airpax

THERMOSTAT 118DEG C NC TO220-2

0

Temperature Sensors - Thermostats - Mechanical

1. Overview

Mechanical temperature sensors and thermostats are electromechanical devices that detect temperature changes through physical deformation or phase-state variations. They convert thermal energy into mechanical displacement to trigger switching actions. These components remain critical in temperature regulation systems where reliability, cost-effectiveness, and simplicity are prioritized over digital precision. Their importance persists in industrial, automotive, and household applications despite advancements in electronic sensors.

2. Main Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
Bimetallic StripUses differential expansion of two metal alloys to bend at specific temperaturesHVAC systems, electric kettles, space heaters
Gas/Vapor-PressureOperates via pressure changes in sealed gas-filled capsulesRefrigeration systems, industrial ovens
Fluid ExpansionRelies on liquid/wax volume changes to actuate mechanical switchesAutomotive engines, radiator systems
Mercury BulbUses mercury's conductivity and thermal expansion for precise switchingMedical equipment, laboratory incubators

3. Structure & Components

Typical construction includes: - Sensing Element: Bimetallic strip, liquid-filled bulb, or gas capsule - Actuation Mechanism: Spring-loaded contacts or mercury tilt switches - Adjustment System: Calibrated springs or set-point knobs - Enclosure: Metal/aluminum housing for thermal conductivity - Electrical Contacts: Silver-nickel or gold-plated terminals

4. Key Technical Specifications

ParameterDescriptionImportance
Temperature RangeOperating limits (-50 C to 300 C typical)Determines application suitability
Accuracy 2 C to 10 C depending on designProcess control reliability
Response Time5-60 secondsSystem reaction speed
Switching Current1-15A ratingsLoad compatibility
Environmental RatingIP54 to IP67 protectionOperational durability

5. Application Fields

  • Industrial: Furnace temperature control, pipeline monitoring
  • Residential: Water heater regulation, HVAC systems
  • Commercial: Refrigeration units, coffee machines
  • Automotive: Engine coolant management, cabin climate control
  • Medical: Incubator temperature maintenance

Case Example: Automotive engines use wax pellet thermostats to regulate coolant flow, maintaining optimal operating temperatures between 90-105 C.

6. Leading Manufacturers

ManufacturerKey ProductsSpecial Features
HoneywellT6000 seriesAdjustable hysteresis, IP65 rating
OMRONE5CC Temperature ControllerDigital display with mechanical backup
TE ConnectivityMA320-12High-vibration resistance design
DanfossKPI 316EFood processing compliant materials

7. Selection Guidelines

Key considerations:

  • Environmental conditions (vibration, humidity, chemical exposure)
  • Required temperature range and switching accuracy
  • Electrical load specifications
  • Actuation speed requirements
  • Mounting configuration and space constraints
  • Regulatory compliance (UL, CSA, CE)

8. Industry Trends

Current developments include: - Hybrid systems integrating mechanical sensors with digital interfaces - Miniaturization for portable device integration - Enhanced materials for extreme temperature applications - Wireless-enabled mechanical-electronic combined systems - Improved hysteresis control for energy-efficient systems

Market projections indicate sustained demand in industrial sectors, with a 3.2% CAGR expected through 2030 despite increasing digital competition.

RFQ BOM Call Skype Email
Top