Temperature Sensors - Thermostats - Mechanical

Image Part Number Description / PDF Quantity Rfq
F20A16005DCFB06E

F20A16005DCFB06E

Cantherm

THERMOSTAT 160DEG C SPST-NC WIRE

190

3455RC 01000237

3455RC 01000237

Honeywell Sensing and Productivity Solutions

THERMOSTAT 113DEG C SPST-NC CYL

1368

OHD1-45B

OHD1-45B

KEMET

THERMOSTAT 45DEG C SPST-NC AXIAL

1183

67L065

67L065

Sensata Technologies – Airpax

THERMOSTAT 65DEG C NC TO220-2

573

67F045-0185

67F045-0185

Sensata Technologies – Airpax

THERMOSTAT 45DEG C NO TO220-2

0

TRS5-120BCR01

TRS5-120BCR01

KEMET

THERMOSTAT 120DEG C MODULE WIRE

28

AA82A10

AA82A10

J.W. Miller / Bourns

THERMOSTAT 82DEG C NC STRAP SLDR

870

CS701525Y

CS701525Y

Cantherm

THERMOSTAT 15DEG C SPST-NC CYL

151

OHD1-40M

OHD1-40M

KEMET

THERMOSTAT 40DEG C SPST-NO AXIAL

273

67F070-0383

67F070-0383

Sensata Technologies – Airpax

THERMOSTAT 70DEG C NO TO220-2

0

F20B070051ZA0060

F20B070051ZA0060

Cantherm

THERMOSTAT 70DEG C SPST-NO 2SIP

0

B12A07505AEDA0GE

B12A07505AEDA0GE

Cantherm

THERMOSTAT 75DEG C SPST-NC RAD

344

MHP-TAT18-9-85

MHP-TAT18-9-85

Wickmann / Littelfuse

THERMOSTAT 85DEG C SPST-NC STRAP

0

3NT01L-H7923

3NT01L-H7923

Sensata Technologies

THERMOSTAT 80DEG C SPST-NC MODUL

0

C51AAA230A-205Y

C51AAA230A-205Y

Sensata Technologies

THERMOSTAT 110DEG C SPST-NO CYL

0

F20A125051ZA0060

F20A125051ZA0060

Cantherm

THERMOSTAT 125DEG C SPST-NC 2SIP

755

67L120P

67L120P

Sensata Technologies – Airpax

THERMOSTAT 120DEG C NC TO220-2

0

TRS5-115BLRVU

TRS5-115BLRVU

KEMET

THERMOSTAT 115DEG C MODULE WIRE

50

CS709015Z

CS709015Z

Cantherm

THERMOSTAT 90DEG C SPST-NO CYL

0

2455RM 80750327

2455RM 80750327

Honeywell Sensing and Productivity Solutions

THERMOSTAT 74DEG C SPST-NC CYL

181

Temperature Sensors - Thermostats - Mechanical

1. Overview

Mechanical temperature sensors and thermostats are electromechanical devices that detect temperature changes through physical deformation or phase-state variations. They convert thermal energy into mechanical displacement to trigger switching actions. These components remain critical in temperature regulation systems where reliability, cost-effectiveness, and simplicity are prioritized over digital precision. Their importance persists in industrial, automotive, and household applications despite advancements in electronic sensors.

2. Main Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
Bimetallic StripUses differential expansion of two metal alloys to bend at specific temperaturesHVAC systems, electric kettles, space heaters
Gas/Vapor-PressureOperates via pressure changes in sealed gas-filled capsulesRefrigeration systems, industrial ovens
Fluid ExpansionRelies on liquid/wax volume changes to actuate mechanical switchesAutomotive engines, radiator systems
Mercury BulbUses mercury's conductivity and thermal expansion for precise switchingMedical equipment, laboratory incubators

3. Structure & Components

Typical construction includes: - Sensing Element: Bimetallic strip, liquid-filled bulb, or gas capsule - Actuation Mechanism: Spring-loaded contacts or mercury tilt switches - Adjustment System: Calibrated springs or set-point knobs - Enclosure: Metal/aluminum housing for thermal conductivity - Electrical Contacts: Silver-nickel or gold-plated terminals

4. Key Technical Specifications

ParameterDescriptionImportance
Temperature RangeOperating limits (-50 C to 300 C typical)Determines application suitability
Accuracy 2 C to 10 C depending on designProcess control reliability
Response Time5-60 secondsSystem reaction speed
Switching Current1-15A ratingsLoad compatibility
Environmental RatingIP54 to IP67 protectionOperational durability

5. Application Fields

  • Industrial: Furnace temperature control, pipeline monitoring
  • Residential: Water heater regulation, HVAC systems
  • Commercial: Refrigeration units, coffee machines
  • Automotive: Engine coolant management, cabin climate control
  • Medical: Incubator temperature maintenance

Case Example: Automotive engines use wax pellet thermostats to regulate coolant flow, maintaining optimal operating temperatures between 90-105 C.

6. Leading Manufacturers

ManufacturerKey ProductsSpecial Features
HoneywellT6000 seriesAdjustable hysteresis, IP65 rating
OMRONE5CC Temperature ControllerDigital display with mechanical backup
TE ConnectivityMA320-12High-vibration resistance design
DanfossKPI 316EFood processing compliant materials

7. Selection Guidelines

Key considerations:

  • Environmental conditions (vibration, humidity, chemical exposure)
  • Required temperature range and switching accuracy
  • Electrical load specifications
  • Actuation speed requirements
  • Mounting configuration and space constraints
  • Regulatory compliance (UL, CSA, CE)

8. Industry Trends

Current developments include: - Hybrid systems integrating mechanical sensors with digital interfaces - Miniaturization for portable device integration - Enhanced materials for extreme temperature applications - Wireless-enabled mechanical-electronic combined systems - Improved hysteresis control for energy-efficient systems

Market projections indicate sustained demand in industrial sectors, with a 3.2% CAGR expected through 2030 despite increasing digital competition.

RFQ BOM Call Skype Email
Top