Humidity, Moisture Sensors

Image Part Number Description / PDF Quantity Rfq
HPP845E131R5

HPP845E131R5

TE Connectivity Measurement Specialties

SENSOR HUMID/TEMP 3V I2C 3% SMD

0

HPP805C031

HPP805C031

TE Connectivity Measurement Specialties

SENSOR HUMIDITY 5V ANALOG 2% MOD

4

HPP809A031

HPP809A031

TE Connectivity Measurement Specialties

SENS HUMID/TEMP 5V ANALOG 2% MOD

1022

HPP815G537

HPP815G537

TE Connectivity Measurement Specialties

VOUT RH/ TEMP MODULE, SIDE CONN

0

HPP805A031

HPP805A031

TE Connectivity Measurement Specialties

SENSOR HUMIDITY 5V ANLG 3% MOD

351

HTU20DF

HTU20DF

TE Connectivity Measurement Specialties

SENSOR HUMID/TEMP 3V 5% W/FILTER

376

HPP815A535

HPP815A535

TE Connectivity Measurement Specialties

VOUT RH/ TEMP MODULE, SIDE CONN

0

HPP845E131R1

HPP845E131R1

TE Connectivity Measurement Specialties

SENSOR HUMID/TEMP 3V I2C 3% SMD

480

HPP845E031R4

HPP845E031R4

TE Connectivity Measurement Specialties

SENSOR HUMID/TEMP 3V I2C 2% SMD

7329

HPP808H031

HPP808H031

TE Connectivity Measurement Specialties

SENSOR HUMID/TEMP 5V FRQ 3% MOD

15

HPP845E132R4

HPP845E132R4

TE Connectivity Measurement Specialties

I.C 21PF RH/T PWM B400

0

HPP845E035R4

HPP845E035R4

TE Connectivity Measurement Specialties

I.C 20P RH/T PWM B400

0

HPP845E131R4

HPP845E131R4

TE Connectivity Measurement Specialties

SENSOR HUMID/TEMP 3V I2C 3% SMD

400

10142048-00

10142048-00

TE Connectivity Measurement Specialties

HTU31D I.C 31D RH/T DIGITAL R400

241

HPP845E032R4

HPP845E032R4

TE Connectivity Measurement Specialties

I.C 21P RH/T PWM B400

0

HPP845E031R1

HPP845E031R1

TE Connectivity Measurement Specialties

SENSOR HUMID/TEMP 3V I2C 2% SMD

651

HPP801A031

HPP801A031

TE Connectivity Measurement Specialties

SENSOR HUMIDITY 10V CAPAC MOD

758

HPP845E031R5

HPP845E031R5

TE Connectivity Measurement Specialties

SENSOR HUMID/TEMP 3V I2C 3% SMD

2234

HTU20D

HTU20D

TE Connectivity Measurement Specialties

SENSOR HUMID/TEMP 3V 5%

204

HPP805D033

HPP805D033

TE Connectivity Measurement Specialties

SENS HUMID/TEMP 5V ANALOG 2% MOD

654

Humidity, Moisture Sensors

1. Overview

Humidity and moisture sensors are transducer devices that measure and report the water vapor content in air or the water content in materials. Humidity sensors quantify relative humidity (RH) or absolute humidity in g/m , while moisture sensors detect moisture levels in solids/liquids. These sensors play a critical role in industrial process control, environmental monitoring, agriculture, and smart home systems by ensuring product quality, optimizing energy efficiency, and maintaining safety standards.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Capacitive Humidity SensorsMeasure dielectric changes in polymer films, high accuracy ( 2% RH), fast responseIndustrial HVAC systems
Resistive Humidity SensorsUse ceramic materials with resistance variation, low cost, moderate accuracyConsumer electronics
Optical Moisture SensorsNon-contact measurement via near-infrared absorption, high precisionFood processing quality control
Dielectric Moisture SensorsMeasure permittivity changes in materials, suitable for solidsAgricultural soil monitoring
Thermal Conductivity SensorsCompare thermal conductivity between dry/wet air, resistant to contaminantsAutomotive defrost systems

3. Structure and Components

Typical sensor architecture includes: (1) Sensing element (polymer, ceramic, or optical material), (2) Electrode structure (interdigitated or parallel plates), (3) Signal conditioning circuitry (amplifiers, ADCs), (4) Protective enclosure (IP65-rated housing). Advanced designs integrate MEMS technology for miniaturization and on-chip calibration memory for improved accuracy.

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement Range0-100% RH for humidity, 0-50% moisture content for solidsDetermines application suitability
Accuracy 1.5% to 5% depending on typeQuality control in critical processes
Response Time5-60 seconds for 90% step changeReal-time monitoring capability
Operating Temperature-40 C to +125 CEnvironmental durability
Long-term StabilityDrift <1% RH/yearReduces calibration frequency

5. Application Areas

  • Industrial: Semiconductor cleanrooms, paper manufacturing
  • Agriculture: Smart irrigation systems, grain storage
  • Medical: Respiratory equipment, pharmaceutical storage
  • Consumer: Smart thermostats, laundry dryers
  • Environmental: Weather stations, corrosion prevention

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
HoneywellHIH-50300-100% RH, 3.5% accuracy, 15ms response
SensirionSHT45I2C interface, 1.8% RH, -40 C to +125 C
TE ConnectivityHH10KLow power consumption: 0.5 A standby
VaisalaHMT333Industrial temperature range: -40 C to +180 C

7. Selection Guidelines

Key considerations: (1) Environmental conditions (temperature extremes, chemical exposure), (2) Required measurement range and accuracy, (3) Output signal type (analog/digital), (4) Long-term stability vs calibration frequency, (5) Cost constraints. For example, capacitive sensors suit general industrial monitoring, while optical sensors are preferred for food safety applications requiring non-contact measurement.

8. Industry Trends

Emerging trends include: (1) Integration of wireless IoT connectivity (LoRaWAN, BLE), (2) Multi-sensor fusion with temperature/pressure compensation, (3) Development of self-calibrating MEMS-based sensors, (4) Adoption of AI algorithms for predictive maintenance. The market is projected to grow at CAGR of 6.2% through 2030, driven by smart agriculture and healthcare monitoring applications.

9. Application Case

In precision agriculture: Dielectric soil moisture sensors (Decagon Devices EC-5) enable automated irrigation systems with 1% volumetric water content accuracy, reducing water usage by 30% in greenhouse tomato cultivation.

RFQ BOM Call Skype Email
Top