Current Sensors

Image Part Number Description / PDF Quantity Rfq
4750-005

4750-005

Aim Dynamics

MAGNELAB SCT-3000-800 800A 333MV

35

4380-005

4380-005

Aim Dynamics

MAGNELAB SCT-1250-250, 250A:333M

88

RCS-1800-400

RCS-1800-400

Aim Dynamics

CURRENT SENSE MAGNA 400A:333MV

20

SCT-0400-015

SCT-0400-015

Aim Dynamics

CURRENT SENSE MAGNALAB 15A:333MV

78

4750-011

4750-011

Aim Dynamics

MAGNELAB SCT-3000-400 3KA 333MV

31

SCT-0750-100

SCT-0750-100

Aim Dynamics

CURRENT SENSE MAGNALB 100A:333MV

0

AIMH040-500A-420B

AIMH040-500A-420B

Aim Dynamics

CURRENT SENSOR 500A 4-20MA

56

AIMH021-100A-420B

AIMH021-100A-420B

Aim Dynamics

CURRENT SENSOR 100A 4-20MA

44

AIMH040-800A-5VT

AIMH040-800A-5VT

Aim Dynamics

CURRENT SENSOR 800A 5V UNIDI

28

AIMH021-200A-5VT

AIMH021-200A-5VT

Aim Dynamics

CURRENT SENSOR 200A 5V UNIDI

93

4381-005

4381-005

Aim Dynamics

MAGNELAB SCT-2000-600, 600A:333M

187

MGS-1800-4000

MGS-1800-4000

Aim Dynamics

MGS-1800-4000 IS A THREE-PHASE R

5

S9XM300A1000VM

S9XM300A1000VM

Aim Dynamics

POWER METER WITH CT TELE

10

4380-004

4380-004

Aim Dynamics

MAGNELAB SCT-1250-200, 200A:333M

132

SCT-0400-075

SCT-0400-075

Aim Dynamics

CURRENT SENSE MAGNALAB 75A:333MV

117

SCT-0400-010

SCT-0400-010

Aim Dynamics

CURRENT SENSE MAGNALAB 10A:333MV

47

RCT-1800-000

RCT-1800-000

Aim Dynamics

CURRENT SENSE MAGNALAB 18"

642

RCT24-1000

RCT24-1000

Aim Dynamics

RCT24-1000 ROGOWSKI COIL OUTPUTS

1686

SCT-0750-050

SCT-0750-050

Aim Dynamics

CURRENT SENSE MAGNALAB 50A:333MV

0

JC36S-500A-V

JC36S-500A-V

Aim Dynamics

CURRENT TRANS J&D 500A 36MM

200

Current Sensors

1. Overview

Current sensors are transducers that measure electric current flow in conductors and convert it into proportional electrical signals. They play critical roles in energy management, motor control, power quality monitoring, and system protection across industries. Modern applications demand high accuracy, galvanic isolation, and fast response times for optimizing efficiency in electrified systems.

2. Major Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
Shunt ResistorLow cost, inline measurement, direct current conversion via Ohm's lawPower supplies, battery management systems
Hall EffectGalvanic isolation, DC/AC measurement, moderate bandwidthAutomotive traction inverters, industrial motor drives
Current TransformerHigh-voltage isolation, AC-only operation, high accuracyGrid metering, circuit breaker protection
Rogowski CoilFlexible coreless design, fast transient response, requires integratorPulsed power systems, fault current detection
Optical Current SensorImmune to EMI, high precision, complex signal processingSmart grids, high-voltage substations

3. Structure & Components

Typical current sensors contain: 1) Sensing element (shunt resistor, Hall chip, magnetic core) 2) Signal conditioning circuitry (amplifiers, filters) 3) Isolation barrier (if applicable) 4) Output interface (analog voltage/current, digital protocols). High-performance models integrate temperature compensation and digital calibration features.

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement RangeMaximum current capacity (e.g., 500A)Determines application suitability
Accuracy ClassError tolerance (e.g., 0.5%)System control reliability
BandwidthFrequency response (DC-100kHz)Dynamic performance capability
Isolation VoltageDielectric withstand rating (e.g., 3kV)Electrical safety compliance
Response TimeSignal output delay ( s-ms range)Protection system effectiveness

5. Application Fields

Key industries include: Renewable energy (solar inverters, wind turbines), Automotive (EV battery management, 48V systems), Industrial automation (CNC machines, robotics), Consumer electronics (smart meters), Aerospace (actuator monitoring). Typical equipment: Variable frequency drives, uninterruptible power supplies, charging stations.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
LEM SAHASS & LTSR SeriesOpen-loop Hall effect with ASIC processing
Allegro MicroACS758/ACS3761xGalvanically isolated Hall ICs
HoneywellCSP-VA/CSNP SeriesCurrent transformers for grid applications
TT ElectronicsPulse SeriesHigh-precision shunt resistors
ACR SystemsRogowski Coil ModelsFlexible aperture AC measurement

7. Selection Recommendations

Key considerations: 1) Required measurement range vs peak currents 2) DC/AC signal type compatibility 3) Isolation requirements 4) Environmental conditions (temperature, vibration) 5) Cost vs performance trade-offs. Example: For EV battery management, select Hall-effect sensors with 200A range, 1% accuracy, and automotive qualification.

8. Industry Trends

Emerging trends include: 1) Integration with IoT for predictive maintenance 2) Wide bandgap semiconductor-based sensors 3) Increased adoption of closed-loop Hall sensors for EV applications 4) MEMS-based miniaturized current monitoring 5) AI-enhanced signal processing for harmonic analysis. The market is projected to grow at 7.2% CAGR through 2030 driven by electrification demands.