Current Sensors

Image Part Number Description / PDF Quantity Rfq
ACS732KLATR-40AB-T

ACS732KLATR-40AB-T

Allegro MicroSystems

AUTOMOTIVE GRADE HIGH BANDWIDTH

0

L08P150D15

L08P150D15

Tamura

SENSOR CURRENT HALL 150A AC/DC

0

HY 25-P

HY 25-P

LEM USA, Inc.

SENSOR CURRENT HALL 25A AC/DC

120

CS15120B

CS15120B

CUI Devices

CURRENT SENSOR,OPEN LOOP,15A,+/-

30

DC1-4MA

DC1-4MA

Aim Dynamics

VOLT TRANS AIM DYN 4-20MA

79

ACS714LLCTR-05B-T

ACS714LLCTR-05B-T

Allegro MicroSystems

SENSOR CURRENT HALL 5A AC/DC

1652

ACS71240LLCBTR-030B3

ACS71240LLCBTR-030B3

Allegro MicroSystems

AUTOMOTIVE-GRADE, GALVANICALLY I

0

MLX91210KDC-CAS-106-SP

MLX91210KDC-CAS-106-SP

Melexis

PLUG & POWER CURRENT SENSOR IC

43

CR4260-20

CR4260-20

CR Magnetics, Inc.

SENSOR CURRENT XFMR 20A AC

24

L07P003D15

L07P003D15

Tamura

SENSOR CURRENT HALL 3A AC/DC

0

ASH50

ASH50

Asentek

HALL-REPLACEMENT TRANS 50A .05%

1

MLX91221KDC-ABF-050-SP

MLX91221KDC-ABF-050-SP

Melexis

IC CURRENT SENSOR P&P 8SOIC

80

CR9580-20

CR9580-20

CR Magnetics, Inc.

SENSOR CURRENT XFMR 20A AC

243

MGS-1800-1000

MGS-1800-1000

Aim Dynamics

MGS-1800-1000 IS A THREE-PHASE R

5

2814359

2814359

Phoenix Contact

CURRENT MEASURING TRANSDUCER

2

HTB 50-TP

HTB 50-TP

LEM USA, Inc.

SENSOR CURRENT HALL 50A AC/DC

10

HTA 1000S

HTA 1000S

LEM USA, Inc.

SENSOR CURRENT HALL 1000A AC/DC

0

CR4110S-10

CR4110S-10

CR Magnetics, Inc.

SENSOR CURRENT XFMR 10A AC

0

L34S600D15

L34S600D15

Tamura

SENSOR CURRENT HALL 600A AC/DC

43

ACS716KLATR-25CB-T

ACS716KLATR-25CB-T

Allegro MicroSystems

SENSOR CURRENT HALL 25A AC/DC

0

Current Sensors

1. Overview

Current sensors are transducers that measure electric current flow in conductors and convert it into proportional electrical signals. They play critical roles in energy management, motor control, power quality monitoring, and system protection across industries. Modern applications demand high accuracy, galvanic isolation, and fast response times for optimizing efficiency in electrified systems.

2. Major Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
Shunt ResistorLow cost, inline measurement, direct current conversion via Ohm's lawPower supplies, battery management systems
Hall EffectGalvanic isolation, DC/AC measurement, moderate bandwidthAutomotive traction inverters, industrial motor drives
Current TransformerHigh-voltage isolation, AC-only operation, high accuracyGrid metering, circuit breaker protection
Rogowski CoilFlexible coreless design, fast transient response, requires integratorPulsed power systems, fault current detection
Optical Current SensorImmune to EMI, high precision, complex signal processingSmart grids, high-voltage substations

3. Structure & Components

Typical current sensors contain: 1) Sensing element (shunt resistor, Hall chip, magnetic core) 2) Signal conditioning circuitry (amplifiers, filters) 3) Isolation barrier (if applicable) 4) Output interface (analog voltage/current, digital protocols). High-performance models integrate temperature compensation and digital calibration features.

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement RangeMaximum current capacity (e.g., 500A)Determines application suitability
Accuracy ClassError tolerance (e.g., 0.5%)System control reliability
BandwidthFrequency response (DC-100kHz)Dynamic performance capability
Isolation VoltageDielectric withstand rating (e.g., 3kV)Electrical safety compliance
Response TimeSignal output delay ( s-ms range)Protection system effectiveness

5. Application Fields

Key industries include: Renewable energy (solar inverters, wind turbines), Automotive (EV battery management, 48V systems), Industrial automation (CNC machines, robotics), Consumer electronics (smart meters), Aerospace (actuator monitoring). Typical equipment: Variable frequency drives, uninterruptible power supplies, charging stations.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
LEM SAHASS & LTSR SeriesOpen-loop Hall effect with ASIC processing
Allegro MicroACS758/ACS3761xGalvanically isolated Hall ICs
HoneywellCSP-VA/CSNP SeriesCurrent transformers for grid applications
TT ElectronicsPulse SeriesHigh-precision shunt resistors
ACR SystemsRogowski Coil ModelsFlexible aperture AC measurement

7. Selection Recommendations

Key considerations: 1) Required measurement range vs peak currents 2) DC/AC signal type compatibility 3) Isolation requirements 4) Environmental conditions (temperature, vibration) 5) Cost vs performance trade-offs. Example: For EV battery management, select Hall-effect sensors with 200A range, 1% accuracy, and automotive qualification.

8. Industry Trends

Emerging trends include: 1) Integration with IoT for predictive maintenance 2) Wide bandgap semiconductor-based sensors 3) Increased adoption of closed-loop Hall sensors for EV applications 4) MEMS-based miniaturized current monitoring 5) AI-enhanced signal processing for harmonic analysis. The market is projected to grow at 7.2% CAGR through 2030 driven by electrification demands.