Current Sensors

Image Part Number Description / PDF Quantity Rfq
ASD1500-SG

ASD1500-SG

Asentek

DIGITAL TRANS 1500A, .02% 15V

0

LA12-60V21

LA12-60V21

KEMET

SENSCURR MAGNETIC DIRECT MDCS 60

172

MGS-1800-4000

MGS-1800-4000

Aim Dynamics

MGS-1800-4000 IS A THREE-PHASE R

5

2904921

2904921

Phoenix Contact

PACT RCP-4000A-1A-D95

96

ACS724LLCTR-30AB-T

ACS724LLCTR-30AB-T

Allegro MicroSystems

SENSOR CURRENT HALL 30A AC/DC

709

S9XM300A1000VM

S9XM300A1000VM

Aim Dynamics

POWER METER WITH CT TELE

10

HAL 50-S/SP1

HAL 50-S/SP1

LEM USA, Inc.

SENSOR CURRENT HALL 50A AC/DC

0

CR4110S-0.5

CR4110S-0.5

CR Magnetics, Inc.

SENSOR CURRENT XFMR 0.5A AC

0

4380-004

4380-004

Aim Dynamics

MAGNELAB SCT-1250-200, 200A:333M

132

MLX91220KDC-ABR-050-SP

MLX91220KDC-ABR-050-SP

Melexis

IC CURRENT SENSOR P&P 8SOIC

78

DHR 1000 C10

DHR 1000 C10

LEM USA, Inc.

SENSOR CURRENT HALL 1000A AC/DC

0

MLX91220KDF-ABF-050-RE

MLX91220KDF-ABF-050-RE

Melexis

IC CURRENT SENSOR P&P 16SOIC

0

L37S300D15M

L37S300D15M

Tamura

SENSOR

0

CR5410-20

CR5410-20

CR Magnetics, Inc.

SENSOR CURRENT HALL 20A AC/DC

31

AT 150 B5

AT 150 B5

LEM USA, Inc.

SENSOR CURRENT XFMR 150A AC

0

LPSR 6-NP KIT

LPSR 6-NP KIT

LEM USA, Inc.

3 PIECE KIT SENSOR CURRENT HALL

6

MLX91206LDC-CAH-003-TU

MLX91206LDC-CAH-003-TU

Melexis

SENSOR CURRENT HALL 25MT AC/DC

0

MLX91206LDC-CAL-002-RE

MLX91206LDC-CAL-002-RE

Melexis

SENSOR CURRENT HALL 10MT AC/DC

0

CR4120S-100

CR4120S-100

CR Magnetics, Inc.

SENSOR CURRENT XFMR 100A AC

0

HAL 200-S

HAL 200-S

LEM USA, Inc.

SENSOR CURRENT HALL 200A AC/DC

0

Current Sensors

1. Overview

Current sensors are transducers that measure electric current flow in conductors and convert it into proportional electrical signals. They play critical roles in energy management, motor control, power quality monitoring, and system protection across industries. Modern applications demand high accuracy, galvanic isolation, and fast response times for optimizing efficiency in electrified systems.

2. Major Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
Shunt ResistorLow cost, inline measurement, direct current conversion via Ohm's lawPower supplies, battery management systems
Hall EffectGalvanic isolation, DC/AC measurement, moderate bandwidthAutomotive traction inverters, industrial motor drives
Current TransformerHigh-voltage isolation, AC-only operation, high accuracyGrid metering, circuit breaker protection
Rogowski CoilFlexible coreless design, fast transient response, requires integratorPulsed power systems, fault current detection
Optical Current SensorImmune to EMI, high precision, complex signal processingSmart grids, high-voltage substations

3. Structure & Components

Typical current sensors contain: 1) Sensing element (shunt resistor, Hall chip, magnetic core) 2) Signal conditioning circuitry (amplifiers, filters) 3) Isolation barrier (if applicable) 4) Output interface (analog voltage/current, digital protocols). High-performance models integrate temperature compensation and digital calibration features.

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement RangeMaximum current capacity (e.g., 500A)Determines application suitability
Accuracy ClassError tolerance (e.g., 0.5%)System control reliability
BandwidthFrequency response (DC-100kHz)Dynamic performance capability
Isolation VoltageDielectric withstand rating (e.g., 3kV)Electrical safety compliance
Response TimeSignal output delay ( s-ms range)Protection system effectiveness

5. Application Fields

Key industries include: Renewable energy (solar inverters, wind turbines), Automotive (EV battery management, 48V systems), Industrial automation (CNC machines, robotics), Consumer electronics (smart meters), Aerospace (actuator monitoring). Typical equipment: Variable frequency drives, uninterruptible power supplies, charging stations.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
LEM SAHASS & LTSR SeriesOpen-loop Hall effect with ASIC processing
Allegro MicroACS758/ACS3761xGalvanically isolated Hall ICs
HoneywellCSP-VA/CSNP SeriesCurrent transformers for grid applications
TT ElectronicsPulse SeriesHigh-precision shunt resistors
ACR SystemsRogowski Coil ModelsFlexible aperture AC measurement

7. Selection Recommendations

Key considerations: 1) Required measurement range vs peak currents 2) DC/AC signal type compatibility 3) Isolation requirements 4) Environmental conditions (temperature, vibration) 5) Cost vs performance trade-offs. Example: For EV battery management, select Hall-effect sensors with 200A range, 1% accuracy, and automotive qualification.

8. Industry Trends

Emerging trends include: 1) Integration with IoT for predictive maintenance 2) Wide bandgap semiconductor-based sensors 3) Increased adoption of closed-loop Hall sensors for EV applications 4) MEMS-based miniaturized current monitoring 5) AI-enhanced signal processing for harmonic analysis. The market is projected to grow at 7.2% CAGR through 2030 driven by electrification demands.

RFQ BOM Call Skype Email
Top