Current Sensors

Image Part Number Description / PDF Quantity Rfq
ACHS-7124-000E

ACHS-7124-000E

Broadcom

HALL EFFECT IC, LF

1728

ACS772ECB-200B-PFF-T

ACS772ECB-200B-PFF-T

Allegro MicroSystems

HIGH ACCURACY, HALL-EFFECT CURRE

0

TLI4970D025T5XUMA1

TLI4970D025T5XUMA1

IR (Infineon Technologies)

IC CURRENT SENSOR 8TISON

54

ACHS-7122-000E

ACHS-7122-000E

Broadcom

HALL EFFECT IC LF

1831

L12P025D15

L12P025D15

Tamura

SENSOR CURRENT HALL 25A AC/DC

0

AIMH021-100A-420B

AIMH021-100A-420B

Aim Dynamics

CURRENT SENSOR 100A 4-20MA

44

CR5211-10

CR5211-10

CR Magnetics, Inc.

SENSOR CURRENT MAGNETIC 10A DC

60

AT 150 B420L

AT 150 B420L

LEM USA, Inc.

SENSOR CURRENT XFMR 150A AC

0

L01Z400S05

L01Z400S05

Tamura

SENSOR CURRENT HALL 400A AC/DC

0

CS1505U

CS1505U

CUI Devices

CURRENT SENSOR, OPEN LOOP, 15 A,

30

CTL0502F

CTL0502F

Red Lion

SENSOR CURRENT XFMR 10A, 20, 50A

0

ASR20

ASR20

Asentek

LOW CURRENT TRANS 20MA 1%

1

CQ2064

CQ2064

Asahi Kasei Microdevices / AKM Semiconductor

SENSOR CURRENT HALL 50A AC/DC

0

DS1000UB-10V

DS1000UB-10V

Danisense

CURRENT TRANSDUCER 1000A

0

CR4220-20

CR4220-20

CR Magnetics, Inc.

SENSOR CURRENT XFMR 15A AC

59

CR9350-NPN

CR9350-NPN

CR Magnetics, Inc.

SENSOR CURRENT SWITCH 100A NPN

0

CTR20000

CTR20000

Red Lion

SENSOR CURRENT 100A, 150A, 200A

0

AIMH040-800A-5VT

AIMH040-800A-5VT

Aim Dynamics

CURRENT SENSOR 800A 5V UNIDI

28

ACS770LCB-050B-PFF-T

ACS770LCB-050B-PFF-T

Allegro MicroSystems

SENSOR CURRENT HALL 50A AC/DC

10529

CR4120S-10

CR4120S-10

CR Magnetics, Inc.

SENSOR CURRENT XFMR 10A AC

0

Current Sensors

1. Overview

Current sensors are transducers that measure electric current flow in conductors and convert it into proportional electrical signals. They play critical roles in energy management, motor control, power quality monitoring, and system protection across industries. Modern applications demand high accuracy, galvanic isolation, and fast response times for optimizing efficiency in electrified systems.

2. Major Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
Shunt ResistorLow cost, inline measurement, direct current conversion via Ohm's lawPower supplies, battery management systems
Hall EffectGalvanic isolation, DC/AC measurement, moderate bandwidthAutomotive traction inverters, industrial motor drives
Current TransformerHigh-voltage isolation, AC-only operation, high accuracyGrid metering, circuit breaker protection
Rogowski CoilFlexible coreless design, fast transient response, requires integratorPulsed power systems, fault current detection
Optical Current SensorImmune to EMI, high precision, complex signal processingSmart grids, high-voltage substations

3. Structure & Components

Typical current sensors contain: 1) Sensing element (shunt resistor, Hall chip, magnetic core) 2) Signal conditioning circuitry (amplifiers, filters) 3) Isolation barrier (if applicable) 4) Output interface (analog voltage/current, digital protocols). High-performance models integrate temperature compensation and digital calibration features.

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement RangeMaximum current capacity (e.g., 500A)Determines application suitability
Accuracy ClassError tolerance (e.g., 0.5%)System control reliability
BandwidthFrequency response (DC-100kHz)Dynamic performance capability
Isolation VoltageDielectric withstand rating (e.g., 3kV)Electrical safety compliance
Response TimeSignal output delay ( s-ms range)Protection system effectiveness

5. Application Fields

Key industries include: Renewable energy (solar inverters, wind turbines), Automotive (EV battery management, 48V systems), Industrial automation (CNC machines, robotics), Consumer electronics (smart meters), Aerospace (actuator monitoring). Typical equipment: Variable frequency drives, uninterruptible power supplies, charging stations.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
LEM SAHASS & LTSR SeriesOpen-loop Hall effect with ASIC processing
Allegro MicroACS758/ACS3761xGalvanically isolated Hall ICs
HoneywellCSP-VA/CSNP SeriesCurrent transformers for grid applications
TT ElectronicsPulse SeriesHigh-precision shunt resistors
ACR SystemsRogowski Coil ModelsFlexible aperture AC measurement

7. Selection Recommendations

Key considerations: 1) Required measurement range vs peak currents 2) DC/AC signal type compatibility 3) Isolation requirements 4) Environmental conditions (temperature, vibration) 5) Cost vs performance trade-offs. Example: For EV battery management, select Hall-effect sensors with 200A range, 1% accuracy, and automotive qualification.

8. Industry Trends

Emerging trends include: 1) Integration with IoT for predictive maintenance 2) Wide bandgap semiconductor-based sensors 3) Increased adoption of closed-loop Hall sensors for EV applications 4) MEMS-based miniaturized current monitoring 5) AI-enhanced signal processing for harmonic analysis. The market is projected to grow at 7.2% CAGR through 2030 driven by electrification demands.

RFQ BOM Call Skype Email
Top