Signal Relays, Up to 2 Amps

Image Part Number Description / PDF Quantity Rfq
2-1617121-3

2-1617121-3

TE Connectivity Aerospace Defense and Marine

JMAC-9XM = M39016/9-059M

0

JMSPD-26XP

JMSPD-26XP

TE Connectivity Aerospace Defense and Marine

JMSPD-26XP=M39016/16-028P

0

4-1617033-5

4-1617033-5

TE Connectivity Aerospace Defense and Marine

HFW1268K01 = HFW 1/2 SIZE RELA

0

7-1617560-3

7-1617560-3

TE Connectivity Aerospace Defense and Marine

3SBC1536A2=M39016/13-071M

0

3SBH5004K1R

3SBH5004K1R

TE Connectivity Aerospace Defense and Marine

RELAY GEN PURPOS 4PDT 2A 26.5VDC

0

JMAWDD-26XM

JMAWDD-26XM

TE Connectivity Aerospace Defense and Marine

JMAWDD-26XM = M39016/20-012M

0

PRMAP-5X

PRMAP-5X

TE Connectivity Aerospace Defense and Marine

PRMAP-5X=PRMA COTS TO-5 RELAY

0

2-1617594-1

2-1617594-1

TE Connectivity Aerospace Defense and Marine

LS-9226=RELAY

0

JMGST-18PW

JMGST-18PW

TE Connectivity Aerospace Defense and Marine

JMGST-18PW=M28776/7-011P

0

3SBC1721A2

3SBC1721A2

TE Connectivity Aerospace Defense and Marine

RELAY GENERAL PURPOSE DPDT 2A

0

1-1617050-8

1-1617050-8

TE Connectivity Aerospace Defense and Marine

RH4C6H2601 = RH 4 POLE RELAY

0

JMAC-26XLS

JMAC-26XLS

TE Connectivity Aerospace Defense and Marine

JMAC-26XLS = M39016/9-076L

0

JMSWD-12XP

JMSWD-12XP

TE Connectivity Aerospace Defense and Marine

JMSWD-12XP=M39016/16-019P

0

1617120-4

1617120-4

TE Connectivity Aerospace Defense and Marine

J1MSW-26XL = M39016/10-023L

0

9-1617351-8

9-1617351-8

TE Connectivity Aerospace Defense and Marine

J1MSP-26XP=M39016/10-024P

0

HCD-12B

HCD-12B

TE Connectivity Aerospace Defense and Marine

HCD-12B = .100 GRID W/DIODE CO

0

3SBH1141A2

3SBH1141A2

TE Connectivity Aerospace Defense and Marine

3SBH1141A2 = M39016/14-001L

0

SF5201J00

SF5201J00

TE Connectivity Aerospace Defense and Marine

SF5201J00 = 2010 SF RELAY

0

1617162-5

1617162-5

TE Connectivity Aerospace Defense and Marine

J1MACDD-26XP = M39016/24-030P

0

8-1617542-6

8-1617542-6

TE Connectivity Aerospace Defense and Marine

JMGAP-5P=M39016/17-025P

0

Signal Relays, Up to 2 Amps

1. Overview

Signal relays with ratings up to 2 amps are electromechanical or solid-state switching devices designed to control low-power electrical circuits. These components enable signal transmission isolation, circuit amplification, or switching automation in modern electronic systems. Their compact size and precise control capabilities make them essential in automation, telecommunications, and precision instrumentation systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic RelaysMechanical switching via electromagnetic coil, standard form factorIndustrial control panels, HVAC systems
Solid-State RelaysNo moving parts, zero-crossing switching, fast responseTemperature control systems, LED lighting
Reed RelaysHermetically sealed contacts, high-speed operationTelecom switching, test equipment
Time Delay RelaysProgrammable switching intervalsMachinery automation, motor starters
High-Frequency RelaysDesigned for RF/microwave signal pathsWireless infrastructure, radar systems

3. Structure and Components

Typical construction includes:

  • Coil assembly (copper winding on bobbin)
  • Contact system (fixed and movable contacts)
  • Insulation housing (flame-retardant polymer)
  • Magnetic circuit (iron core and yoke)
  • Terminal system (PCB pins or screw terminals)

Advanced models incorporate EMI suppression circuits and LED status indicators.

4. Key Technical Parameters

ParameterTypical ValueImportance
Rated Current1-2 A resistiveDetermines load capacity
Coil Voltage5-48 VDC nominalDictates control circuit design
Contact Resistance<50 m Impacts signal integrity
Insulation Resistance>100 M Safety isolation performance
Mechanical Life10-100 million operationsDurability indicator
Switching Speed5-15 ms (EMR), <1 ms (SSR)System response time

5. Application Fields

  • Industrial automation (PLCs, sensor interfaces)
  • Telecom infrastructure (signal routing switches)
  • Medical equipment (diagnostic device controls)
  • Smart home systems (HVAC thermostats)
  • Test & measurement (ATE machine interfaces)

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
OmronG5LE-14-DC55 mm spacing, 2 A rating
Phoenix ContactPSR-SCP-24UCPlug-in design, LED indicators
TE ConnectivityRTX-S-DC5VAutomotive qualified
Siemens3RT2025Modular mounting system

7. Selection Recommendations

Key considerations:

  • Load type (resistive/inductive)
  • Environmental conditions (temperature/humidity)
  • Required make/break cycles
  • Regulatory certifications (UL/CSA/IEC)
  • PCB footprint constraints

Example: For medical equipment, select RoHS-compliant reed relays with 1.5 A rating and reinforced insulation.

8. Industry Trends

Current developments include:

  • Transition to surface-mount solid-state alternatives
  • Integration with IoT-enabled monitoring systems
  • Nanocoating for harsh environment protection
  • Increased adoption of 1 Form C contacts
  • Miniaturization (sub-10 mm package development)

Market forecasts predict 5.2% CAGR through 2027 driven by industrial automation growth.