Signal Relays, Up to 2 Amps

Image Part Number Description / PDF Quantity Rfq
JMAPDD-5XL

JMAPDD-5XL

TE Connectivity Aerospace Defense and Marine

JMAPDD-5XL = M39016/20-037L

0

1617128-6

1617128-6

TE Connectivity Aerospace Defense and Marine

JMSCD-18XM = M39016/16-040M

0

5-1617534-2

5-1617534-2

TE Connectivity Aerospace Defense and Marine

HFW1201K146=HFW 1/2 SIZE RELAY

0

JMGACD-5P

JMGACD-5P

TE Connectivity Aerospace Defense and Marine

JMGACD-5P=M39016/18-031P

0

3SBH5004K2

3SBH5004K2

TE Connectivity Aerospace Defense and Marine

RELAY GEN PURPOS 4PDT 2A 26.5VDC

0

3SBC1623A2

3SBC1623A2

TE Connectivity Aerospace Defense and Marine

3SBC1623A2=M39016/37-023L

0

9-1617514-8

9-1617514-8

TE Connectivity Aerospace Defense and Marine

RELAY GENERAL PURPOSE DPDT 2A

0

5-1617032-1

5-1617032-1

TE Connectivity Aerospace Defense and Marine

HFW1201S59 = HFW 1/2 SIZE RELA

0

JMAWD-5XM

JMAWD-5XM

TE Connectivity Aerospace Defense and Marine

JMAWD-5XM = M39016/15-034M

0

5-1617592-8

5-1617592-8

TE Connectivity Aerospace Defense and Marine

JMSPT-12XM=M28776/3-028M

0

9-1617515-1

9-1617515-1

TE Connectivity Aerospace Defense and Marine

3SBH1195A2=M39016/53-006L

0

JMGAPDD-18P

JMGAPDD-18P

TE Connectivity Aerospace Defense and Marine

JMGAPDD-18P = M39016/19-029P

0

3-1617162-1

3-1617162-1

TE Connectivity Aerospace Defense and Marine

J1MSPT-5XM = M28776/4-025M

0

6-1617520-7

6-1617520-7

TE Connectivity Aerospace Defense and Marine

22RJC-2500G-SIL=RELAY,ELECTROM

0

1-1617350-3

1-1617350-3

TE Connectivity Aerospace Defense and Marine

LSEW-2C-24A=1/2 LATCH 2 POLE S

0

PR1MSPD-5X

PR1MSPD-5X

TE Connectivity Aerospace Defense and Marine

PR1MSPD-5X=RELAY

0

JMAPT-5XP

JMAPT-5XP

TE Connectivity Aerospace Defense and Marine

JMAPT-5XP = M28776/1-019P

0

JMGSCDDG-26LW

JMGSCDDG-26LW

TE Connectivity Aerospace Defense and Marine

JMGSCDDG-26LW=M39016/43-070L

0

1617522-2

1617522-2

TE Connectivity Aerospace Defense and Marine

3SAF2228A2=2PDT FULL SIZE GRID

0

6-1617350-3

6-1617350-3

TE Connectivity Aerospace Defense and Marine

J1MSC-18XM=M39016/10-040M

0

Signal Relays, Up to 2 Amps

1. Overview

Signal relays with ratings up to 2 amps are electromechanical or solid-state switching devices designed to control low-power electrical circuits. These components enable signal transmission isolation, circuit amplification, or switching automation in modern electronic systems. Their compact size and precise control capabilities make them essential in automation, telecommunications, and precision instrumentation systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic RelaysMechanical switching via electromagnetic coil, standard form factorIndustrial control panels, HVAC systems
Solid-State RelaysNo moving parts, zero-crossing switching, fast responseTemperature control systems, LED lighting
Reed RelaysHermetically sealed contacts, high-speed operationTelecom switching, test equipment
Time Delay RelaysProgrammable switching intervalsMachinery automation, motor starters
High-Frequency RelaysDesigned for RF/microwave signal pathsWireless infrastructure, radar systems

3. Structure and Components

Typical construction includes:

  • Coil assembly (copper winding on bobbin)
  • Contact system (fixed and movable contacts)
  • Insulation housing (flame-retardant polymer)
  • Magnetic circuit (iron core and yoke)
  • Terminal system (PCB pins or screw terminals)

Advanced models incorporate EMI suppression circuits and LED status indicators.

4. Key Technical Parameters

ParameterTypical ValueImportance
Rated Current1-2 A resistiveDetermines load capacity
Coil Voltage5-48 VDC nominalDictates control circuit design
Contact Resistance<50 m Impacts signal integrity
Insulation Resistance>100 M Safety isolation performance
Mechanical Life10-100 million operationsDurability indicator
Switching Speed5-15 ms (EMR), <1 ms (SSR)System response time

5. Application Fields

  • Industrial automation (PLCs, sensor interfaces)
  • Telecom infrastructure (signal routing switches)
  • Medical equipment (diagnostic device controls)
  • Smart home systems (HVAC thermostats)
  • Test & measurement (ATE machine interfaces)

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
OmronG5LE-14-DC55 mm spacing, 2 A rating
Phoenix ContactPSR-SCP-24UCPlug-in design, LED indicators
TE ConnectivityRTX-S-DC5VAutomotive qualified
Siemens3RT2025Modular mounting system

7. Selection Recommendations

Key considerations:

  • Load type (resistive/inductive)
  • Environmental conditions (temperature/humidity)
  • Required make/break cycles
  • Regulatory certifications (UL/CSA/IEC)
  • PCB footprint constraints

Example: For medical equipment, select RoHS-compliant reed relays with 1.5 A rating and reinforced insulation.

8. Industry Trends

Current developments include:

  • Transition to surface-mount solid-state alternatives
  • Integration with IoT-enabled monitoring systems
  • Nanocoating for harsh environment protection
  • Increased adoption of 1 Form C contacts
  • Miniaturization (sub-10 mm package development)

Market forecasts predict 5.2% CAGR through 2027 driven by industrial automation growth.

RFQ BOM Call Skype Email
Top