Signal Relays, Up to 2 Amps

Image Part Number Description / PDF Quantity Rfq
HFW1130G01

HFW1130G01

TE Connectivity Aerospace Defense and Marine

HFW1130G01 = M39016/6-111L

0

J1MSCT-26XM

J1MSCT-26XM

TE Connectivity Aerospace Defense and Marine

J1MSCT-26XM=M28776/4-038M

0

1-1617532-1

1-1617532-1

TE Connectivity Aerospace Defense and Marine

HF1119K01=HF 1/2 SIZE RELAY 2

0

4-1617670-3

4-1617670-3

TE Connectivity Aerospace Defense and Marine

MAPD-9=RELAY

0

JMACD-18XL

JMACD-18XL

TE Connectivity Aerospace Defense and Marine

JMACD-18XL = M39016/15-080L

0

JMAP-26XP

JMAP-26XP

TE Connectivity Aerospace Defense and Marine

JMAP-26XP = M39016/9-024P

0

JMGSCD-26L

JMGSCD-26L

TE Connectivity Aerospace Defense and Marine

JMGSCD-26L=M39016/42-036L

0

4-1617076-2

4-1617076-2

TE Connectivity Aerospace Defense and Marine

3SBH5004G6R = RELAY

0

JMACDG-12XMS

JMACDG-12XMS

TE Connectivity Aerospace Defense and Marine

JMACDG-12XMS=M39016/15-115M

0

SMGSD-18

SMGSD-18

TE Connectivity Aerospace Defense and Marine

SMGSD-18=SURFACE MOUNT .100 GR

0

1617088-9

1617088-9

TE Connectivity Aerospace Defense and Marine

3SAM1750A2 = RELAY - POLARIZED

0

3-1617146-7

3-1617146-7

TE Connectivity Aerospace Defense and Marine

JMGACDG-26PW = M39016/18-054P

0

4-1617032-2

4-1617032-2

TE Connectivity Aerospace Defense and Marine

HFW1201S351 = HFW 1/2 SIZE REL

0

JMAPT-26XM

JMAPT-26XM

TE Connectivity Aerospace Defense and Marine

JMAPT-26XM = M28776/1-024M

0

PRMGSPD-26XW

PRMGSPD-26XW

TE Connectivity Aerospace Defense and Marine

PRMGSPD-26XW=PRMGSD .100 GRID C

0

JMGACDG-5PW

JMGACDG-5PW

TE Connectivity Aerospace Defense and Marine

JMGACDG-5PW = M39016/18-049P

0

2-1617534-3

2-1617534-3

TE Connectivity Aerospace Defense and Marine

HFW1201G14P=M39016/6-144P

0

3-1617118-4

3-1617118-4

TE Connectivity Aerospace Defense and Marine

J1MACDD-5XPS = M39016/24-031P

0

HFW1231K05M

HFW1231K05M

TE Connectivity Aerospace Defense and Marine

HFW1231K05M = M39016/6-125M

0

J1MACD-26XLS

J1MACD-26XLS

TE Connectivity Aerospace Defense and Marine

J1MACD-26XLS=M39016/23-036L

0

Signal Relays, Up to 2 Amps

1. Overview

Signal relays with ratings up to 2 amps are electromechanical or solid-state switching devices designed to control low-power electrical circuits. These components enable signal transmission isolation, circuit amplification, or switching automation in modern electronic systems. Their compact size and precise control capabilities make them essential in automation, telecommunications, and precision instrumentation systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic RelaysMechanical switching via electromagnetic coil, standard form factorIndustrial control panels, HVAC systems
Solid-State RelaysNo moving parts, zero-crossing switching, fast responseTemperature control systems, LED lighting
Reed RelaysHermetically sealed contacts, high-speed operationTelecom switching, test equipment
Time Delay RelaysProgrammable switching intervalsMachinery automation, motor starters
High-Frequency RelaysDesigned for RF/microwave signal pathsWireless infrastructure, radar systems

3. Structure and Components

Typical construction includes:

  • Coil assembly (copper winding on bobbin)
  • Contact system (fixed and movable contacts)
  • Insulation housing (flame-retardant polymer)
  • Magnetic circuit (iron core and yoke)
  • Terminal system (PCB pins or screw terminals)

Advanced models incorporate EMI suppression circuits and LED status indicators.

4. Key Technical Parameters

ParameterTypical ValueImportance
Rated Current1-2 A resistiveDetermines load capacity
Coil Voltage5-48 VDC nominalDictates control circuit design
Contact Resistance<50 m Impacts signal integrity
Insulation Resistance>100 M Safety isolation performance
Mechanical Life10-100 million operationsDurability indicator
Switching Speed5-15 ms (EMR), <1 ms (SSR)System response time

5. Application Fields

  • Industrial automation (PLCs, sensor interfaces)
  • Telecom infrastructure (signal routing switches)
  • Medical equipment (diagnostic device controls)
  • Smart home systems (HVAC thermostats)
  • Test & measurement (ATE machine interfaces)

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
OmronG5LE-14-DC55 mm spacing, 2 A rating
Phoenix ContactPSR-SCP-24UCPlug-in design, LED indicators
TE ConnectivityRTX-S-DC5VAutomotive qualified
Siemens3RT2025Modular mounting system

7. Selection Recommendations

Key considerations:

  • Load type (resistive/inductive)
  • Environmental conditions (temperature/humidity)
  • Required make/break cycles
  • Regulatory certifications (UL/CSA/IEC)
  • PCB footprint constraints

Example: For medical equipment, select RoHS-compliant reed relays with 1.5 A rating and reinforced insulation.

8. Industry Trends

Current developments include:

  • Transition to surface-mount solid-state alternatives
  • Integration with IoT-enabled monitoring systems
  • Nanocoating for harsh environment protection
  • Increased adoption of 1 Form C contacts
  • Miniaturization (sub-10 mm package development)

Market forecasts predict 5.2% CAGR through 2027 driven by industrial automation growth.