Safety Relays

Image Part Number Description / PDF Quantity Rfq
44510-1212

44510-1212

Omron Automation & Safety Services

SR121E02, 110VAC, 2 INPUT, 4 OUT

0

44510-2241

44510-2241

Omron Automation & Safety Services

SR224SMT01, 24VAC/DC, PULSE DEL

0

G9S-301 DC24

G9S-301 DC24

Omron Automation & Safety Services

G9S-301 DC24

0

44510-0530

44510-0530

Omron Automation & Safety Services

SR08 24VAC/DC 1 INPUT 3 OUTPUT

0

44510-1211

44510-1211

Omron Automation & Safety Services

SR121E01, 24VAC/DC, 2 INPUT, 4 O

0

44510-1063

44510-1063

Omron Automation & Safety Services

SR106ED03 EXPANDER, 230VAC

0

SR07P110

SR07P110

Omron Automation & Safety Services

RELAY SAFETY 3PST 4A 110V

0

FGRMS51-24-LED

FGRMS51-24-LED

Omron Automation & Safety Services

FGRMS51, 24VDC, 5NO+1NC

0

44510-2202

44510-2202

Omron Automation & Safety Services

SR220MP02, 110VAC, 2 INPUT 3 OUT

0

44510-2040

44510-2040

Omron Automation & Safety Services

SR204P00, 24VDC, 2 HAND CONTROL

0

44510-1250

44510-1250

Omron Automation & Safety Services

SR125SMS00, 24VDC, STOP MOTION

0

44510-2201

44510-2201

Omron Automation & Safety Services

SR220MP01, 24VAC/DC, 2 INPUT 3 O

0

FGRMS51-24

FGRMS51-24

Omron Automation & Safety Services

FGRMS51, 24VDC, 5NO+1NC

0

44510-0450

44510-0450

Omron Automation & Safety Services

SR11 24VAC/DC 2 INPUTS 3 OUTPUTS

0

SR06AM110

SR06AM110

Omron Automation & Safety Services

RELAY SAFETY 3PST 4A 110V

0

44510-2300

44510-2300

Omron Automation & Safety Services

SR230DD00, 24VDC, 2 SETS OF 3 OU

0

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities