Safety Relays

Image Part Number Description / PDF Quantity Rfq
56.OA12.0642C

56.OA12.0642C

Altech Corporation

OA5612 6V 4NO/2NC AGSN02+02UMAU

0

56.OA44.0622C

56.OA44.0622C

Altech Corporation

OA5644 6VDC2NO/2NC CONTACTS AGSN

0

56.OA02.2433S

56.OA02.2433S

Altech Corporation

OA560224V 3NO/3NC AGNI10+5UMAU I

0

56.OA69.1200C

56.OA69.1200C

Altech Corporation

OA566912V 2CO AGSN02+02UMAU IP40

0

456.OA11.2422N

456.OA11.2422N

Altech Corporation

SAFETY MODULE 4 CH 4P8A 24V 2NO/

0

56.OA44.4822C

56.OA44.4822C

Altech Corporation

OA5644 48VDC2NO/2NC CONTACTS AGS

0

56.OA03.2471C

56.OA03.2471C

Altech Corporation

OA560324V 7NO/1NC AGSN02+02UMAU

0

56.OA44.2422S

56.OA44.2422S

Altech Corporation

OA5644 24VDC2NO/2NC CONTACTS AGN

0

156.OA12.1224C

156.OA12.1224C

Altech Corporation

RELAY SAFETY 6PST 8A 12V

0

256.OA12.2433C

256.OA12.2433C

Altech Corporation

2 CHANNEL MODULE 6P 8A 24V 3NO/3

0

56.OA03.1262S

56.OA03.1262S

Altech Corporation

OA560312V 6NO/2NC AGNI10+5UMAU I

0

56.OA03.1253C

56.OA03.1253C

Altech Corporation

OA560312V 5NO/3NC AGSN02+02UMAU

15

56.OA69.2011C

56.OA69.2011C

Altech Corporation

OA566920V 1NO/1NC AGSN02+02UMAU

0

56.OA70.0622S

56.OA70.0622S

Altech Corporation

OA5670 6VDC 2NO/2NC CONTACTS AGN

0

156.OA12.2433C

156.OA12.2433C

Altech Corporation

RELAY SAFETY 6PST 8A 24V

0

8972.2C

8972.2C

Altech Corporation

RM2G16 16CHAN SAFETY RELAY MODUL

0

56.OA67.0600C

56.OA67.0600C

Altech Corporation

OA5667 6V 2CO CONTACTS AGSN02+02

0

56.OA44.0622S

56.OA44.0622S

Altech Corporation

OA5644 6VDC2NO/2NC CONTACTS AGNI

0

56.OA11.0622S

56.OA11.0622S

Altech Corporation

OA5611 6V 2NO/2NC AGNI10+5UMAU I

0

56.OW70.2422C

56.OW70.2422C

Altech Corporation

OW5670 24VDC2NO/2NC CONTACTS AGS

0

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities