Safety Relays

Image Part Number Description / PDF Quantity Rfq
G9SB-2002-A AC/DC24

G9SB-2002-A AC/DC24

Omron Automation & Safety Services

G9SB-2002-A AC/DC24

2

SR101A01

SR101A01

Omron Automation & Safety Services

RELAY SAFETY DPST 4A 24V

0

2702902

2702902

Phoenix Contact

SAFETY RELAY 6A 24V

10

2986960

2986960

Phoenix Contact

RELAY SAFETY DPST 5A 24V

7206

G7SA-2A2B-DC24

G7SA-2A2B-DC24

Omron Automation & Safety Services

RELAY SAFETY 4PST 6A 24V

1010

2902725

2902725

Phoenix Contact

PSR-SCP- 24DC/MXF1/4X1/2X2/B

0

SFS2-DC24V

SFS2-DC24V

Panasonic

RELAY SAFETY 4PST 6A 24V

175

UE11-4DX3D33

UE11-4DX3D33

SICK

RELAY SAFETY 7PST 6A 24V

0

G9SA-301-P DC24

G9SA-301-P DC24

Omron Automation & Safety Services

RELAY SAFETY 3P 24V

28

SR108AD01

SR108AD01

Omron Automation & Safety Services

RELAY SAFETY SPST X 4 8A 24V

4

2963721

2963721

Phoenix Contact

RELAY SAFETY DPST 6A 24V

214

2963802

2963802

Phoenix Contact

RELAY SAFETY SPST X 4 6A 24V

30214

2700588

2700588

Phoenix Contact

RELAY SAFETY DPST 6A 24V

4

MSI-RM2B-01

MSI-RM2B-01

Leuze

SAFETY RELAY

65

RF1V-5A1BL-D24

RF1V-5A1BL-D24

IDEC

RELAY GEN PURPOSE 6PST 6A 24V

13

G1501S

G1501S

ifm Efector

SAFETY RELAY

0

UE43-3MF2A1

UE43-3MF2A1

SICK

RELAY SAFETY 4PST 6A 115V

0

SFS4-L-DC48V-D

SFS4-L-DC48V-D

Panasonic

RELAY SAFETY 6PST 6A 48V

0

50.12.9.024.5000

50.12.9.024.5000

Finder Relays, Inc.

RELAY GUIDED DPDT 8A 24V DC

71

V23047-A1006-A511

V23047-A1006-A511

TE Connectivity Potter & Brumfield Relays

RELAY SAFETY DPST 6A 6V

0

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities
RFQ BOM Call Skype Email
Top