Safety Relays

Image Part Number Description / PDF Quantity Rfq
V23050A1005A533

V23050A1005A533

TE Connectivity Potter & Brumfield Relays

RELAY SAFETY

0

56.OA70.2031C

56.OA70.2031C

Altech Corporation

OA567020VDC3NO/1NC CONTACTS AGSN

0

8949.3C

8949.3C

Altech Corporation

SAFETY RELAY 12VDC DPDT CONTAC C

0

2981143

2981143

Phoenix Contact

RELAY SAFETY 3PST 6A 24V

9

607.5111.010

607.5111.010

Altech Corporation

SAFETY RELAY SCR4-W22-35-SD

2

2700548

2700548

Phoenix Contact

PSR-MC34-3NO-1DO-24DC-SP

0

8955.2/P

8955.2/P

Altech Corporation

SAFETY RELAY 4CH MOD 12VDC DPDTP

0

8955.2N

8955.2N

Altech Corporation

SAFETY RELAY 4CH 12VDC DPDT CONT

0

56.OA44.6031N

56.OA44.6031N

Altech Corporation

OA5644 60VDC3NO/1NC CONTACTS AGN

0

56.OA02.2442C

56.OA02.2442C

Altech Corporation

OA560224V 4NO/2NC AGSN02+02UMAU

0

G7SA-3A3B DC110

G7SA-3A3B DC110

Omron Automation & Safety Services

RELAY SAFETY 6PST 6A 110V

0

56.OA44.0631S

56.OA44.0631S

Altech Corporation

OA5644 6VDC3NO/1NC CONTACTS AGNI

0

56.OA42.4811S

56.OA42.4811S

Altech Corporation

OA5642 48VDC1NO/1NC CONTACTS AGN

0

56.OA01.1222C

56.OA01.1222C

Altech Corporation

OA560112V 2NO/2NC AGSN02+02UMAU

0

607.5111.009

607.5111.009

Altech Corporation

SAFETY RELAY SCR4-W22-35-D

4

2981745

2981745

Phoenix Contact

RELAY SAFETY

1

56.OA70.2431C

56.OA70.2431C

Altech Corporation

OA5670 24VDC3NO/1NC CONTACTS AGS

0

UE23-2MF2A3

UE23-2MF2A3

SICK

RELAY SAFETY 3PST 6A 230V

0

256.OA01.2431C

256.OA01.2431C

Altech Corporation

2 CHANNEL MODULE 4P10A 24V 3NO/1

0

456.OA02.1242C

456.OA02.1242C

Altech Corporation

SAFETY MODULE 4 CH 6P10A 12V 4NO

0

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities
RFQ BOM Call Skype Email