Safety Relays

Image Part Number Description / PDF Quantity Rfq
56.OA44.4831N

56.OA44.4831N

Altech Corporation

OA5644 48VDC3NO/1NC CONTACTS AGN

0

56.OW70.1122C

56.OW70.1122C

Altech Corporation

OW5670 6VDC3NO/1NC CONTACTS AGSN

0

56.OA44.4831S

56.OA44.4831S

Altech Corporation

OA5644 48VDC3NO/1NC CONTACTS AGN

0

7S.23.9.048.0210

7S.23.9.048.0210

Finder Relays, Inc.

SFTY RLY GUIDE 2NO+1NC 10A 48VDC

0

56.OA12.0633S

56.OA12.0633S

Altech Corporation

OA5612 6V 3NO/3NC AGNI10+5UMAU I

0

V23050A1085A533

V23050A1085A533

TE Connectivity Potter & Brumfield Relays

RELAY SAFETY 6PST 8A 85V

0

56.OA03.1262C

56.OA03.1262C

Altech Corporation

OA560312V 6NO/2NC AGSN02+02UMAU

0

456.OA12.1233C

456.OA12.1233C

Altech Corporation

SAFETY MODULE 4 CH 6P 8A 12V 3NO

0

56.OA01.2431N

56.OA01.2431N

Altech Corporation

OA560124V 3NO/1NC AGNI10+2UMAU I

0

8972.2N

8972.2N

Altech Corporation

RM2G16 16CHAN SAFETY RELAY MODUL

0

7S.14.9.110.4220

7S.14.9.110.4220

Finder Relays, Inc.

SFTY RLY GUIDE 2NO+2NC 6A 110VDC

0

56.OA22.1133C

56.OA22.1133C

Altech Corporation

OA5622110VDC3NO/3NC CONTACTS AGS

0

56.OA11.4822C

56.OA11.4822C

Altech Corporation

OA561148V 2NO/2NC AGSN02+02UMAU

0

56.OA11.1131S

56.OA11.1131S

Altech Corporation

OA5611110V3NO/1NC AGNI10+5UMAU I

0

56.OA02.2433N

56.OA02.2433N

Altech Corporation

OA560224V 3NO/3NC AGNI10+2UMAU I

0

256.OA02.2433C

256.OA02.2433C

Altech Corporation

2 CHANNEL MODULE 6P10A 12V 3NO/3

0

607.5111.016

607.5111.016

Altech Corporation

SAFETY RELAY SCR2-W22-25-S

0

456.OA12.2424C

456.OA12.2424C

Altech Corporation

SAFETY MODULE 4 CH 6P 8A 24V 2NO

0

156.OA12.1242C

156.OA12.1242C

Altech Corporation

RELAY SAFETY 6PST 8A 12V

0

7S.63.9.048.0211

7S.63.9.048.0211

Finder Relays, Inc.

SFTY RLY GUIDE 2NO+1NC 6A 48VDC

0

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities
RFQ BOM Call Skype Email
Top