Safety Relays

Image Part Number Description / PDF Quantity Rfq
56.OA43.0621N

56.OA43.0621N

Altech Corporation

OA5643 6VDC2NO/1NC CONTACTS AGNI

0

56.OA43.1221C

56.OA43.1221C

Altech Corporation

OA5643 12VDC2NO/1NC CONTACTS AGS

0

56.OW69.2000C

56.OW69.2000C

Altech Corporation

OW566920V 2CO AGSN02+02UMAU IP67

0

4-1415542-3

4-1415542-3

TE Connectivity Potter & Brumfield Relays

RELAY SAFETY

0

56.OA02.2442N

56.OA02.2442N

Altech Corporation

OA560224V 4NO/2NC AGNI10+2UMAU I

0

56.OA22S.1233S

56.OA22S.1233S

Altech Corporation

OA5622S12VDC3NO/3NC CONTACTS AGN

0

56.OA42.1211S

56.OA42.1211S

Altech Corporation

OA5642 12VDC1NO/1NC CONTACTS AGN

0

56.OA01.1131S

56.OA01.1131S

Altech Corporation

OA5601110V3NO/1NC AGNI10+5UMAU I

0

56.OA44.1222S

56.OA44.1222S

Altech Corporation

OA5644 12VDC2NO/2NC CONTACTS AGN

0

56.OA01.1222S

56.OA01.1222S

Altech Corporation

OA560112V 2NO/2NC AGNI10+5UMAU I

0

56.OA44.6022N

56.OA44.6022N

Altech Corporation

OA5644 60VDC2NO/2NC CONTACTS AGN

0

56.OA42.0611C

56.OA42.0611C

Altech Corporation

OA5642 6VDC1NO/1NC CONTACTS AGSN

0

56.OW70.0631C

56.OW70.0631C

Altech Corporation

OW5670 6VDC2NO/2NC CONTACTS AGSN

0

56.OA01.1231S

56.OA01.1231S

Altech Corporation

OA560112V 3NO/1NC AGNI10+5UMAU I

0

56.OA70.1131C

56.OA70.1131C

Altech Corporation

OA5670110VDC3NO/1NC CONTACTS AGS

0

56.OA42.1111S

56.OA42.1111S

Altech Corporation

OA5642 110VDC1NO/1NC CONTACT AGN

0

456.OA02.2433C

456.OA02.2433C

Altech Corporation

SAFETY MODULE 4 CH 6P10A 12V 3NO

0

56.OA03.1253S

56.OA03.1253S

Altech Corporation

OA560312V 5NO/3NC AGNI10+5UMAU I

0

7S.43.9.024.0211

7S.43.9.024.0211

Finder Relays, Inc.

SFTY RLY GUIDE 2NO+1NC 6A 24VDC

0

56.OA44.2422C

56.OA44.2422C

Altech Corporation

OA5644 24VDC2NO/2NC CONTACTS AGS

0

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities
RFQ BOM Call Skype Email
Top