Safety Relays

Image Part Number Description / PDF Quantity Rfq
7S.23.9.012.0210

7S.23.9.012.0210

Finder Relays, Inc.

SFTY RLY GUIDE 2NO+1NC 10A 12VDC

0

7S.34.8.120.4220

7S.34.8.120.4220

Finder Relays, Inc.

SFTY RLY GUIDE 2NO+2NC 6A 120VAC

0

56.OA22.1142C

56.OA22.1142C

Altech Corporation

OA5622110VDC4NO/2NC CONTACTS AGS

0

56.OA11.2422S

56.OA11.2422S

Altech Corporation

OA561124V 2NO/2NC AGNI10+5UMAU I

0

4-1415542-4

4-1415542-4

TE Connectivity Potter & Brumfield Relays

RELAY SAFETY

0

56.OA02.1124N

56.OA02.1124N

Altech Corporation

OA5602110V2NO/4NC AGNI10+2UMAU I

0

56.OA44.4822N

56.OA44.4822N

Altech Corporation

OA5644 48VDC2NO/2NC CONTACTS AGN

0

8951.3C

8951.3C

Altech Corporation

SAFETY RELAY 2CH DPDT 24VDC CONT

0

56.OA03.2471N

56.OA03.2471N

Altech Corporation

OA560324V 7NO/1NC AGNI10+2UMAU I

0

2981732

2981732

Phoenix Contact

RELAY SAFETY

0

7S.16.9.110.5420

7S.16.9.110.5420

Finder Relays, Inc.

SFTY RLY GUIDE 4NO+2NC 6A 110VDC

0

56.OA44.1131N

56.OA44.1131N

Altech Corporation

OA5644 110VDC3NO/1NC CONTACT AGN

0

256.OA11.1222N

256.OA11.1222N

Altech Corporation

2 CHANNEL MODULE 4P8A 12V 2NO/2N

0

56.OA11.0631S

56.OA11.0631S

Altech Corporation

OA5611 6V 3NO/1NC AGNI10+5UMAU I

0

56.OA70.0631N

56.OA70.0631N

Altech Corporation

OA5670 6VDC 3NO/1NC CONTACTS AGN

0

7S.34.9.024.4220

7S.34.9.024.4220

Finder Relays, Inc.

SFTY RLY GUIDE 2NO+2NC 6A 24VDC

0

56.OA01.2422N

56.OA01.2422N

Altech Corporation

OA560124V 2NO/2NC AGNI10+2UMAU I

0

56.OW70.0631S

56.OW70.0631S

Altech Corporation

OW5670 6VDC3NO/1NC CONTACTS AGNI

0

56.OA44.4831C

56.OA44.4831C

Altech Corporation

OA5644 48VDC3NO/1NC CONTACTS AGS

0

456.OA02.2442C

456.OA02.2442C

Altech Corporation

SAFETY MODULE 4 CH 6P10A 24V 4NO

0

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities
RFQ BOM Call Skype Email
Top