Safety Relays

Image Part Number Description / PDF Quantity Rfq
2981431

2981431

Phoenix Contact

RELAY SAFETY 3PST 6A 24V

28

2981525

2981525

Phoenix Contact

RELAY SAFETY 5PST 6A 24V

1

2981363

2981363

Phoenix Contact

SAFETY RELAY 2PDT 24VAC/DC

125147

SR4M4024

SR4M4024

TE Connectivity Potter & Brumfield Relays

RELAY SAFETY 4PST 8A 24V

1831

SR203AM01

SR203AM01

Omron Automation & Safety Services

SR202 INPUTS 3 OUT

5

SR4D4012

SR4D4012

TE Connectivity Potter & Brumfield Relays

RELAY SAFETY 4PST 8A 12V

1717

UE45-3S12D33

UE45-3S12D33

SICK

RELAY SAFETY 3PST 6A 24V

2

V23050A1048A542

V23050A1048A542

TE Connectivity Potter & Brumfield Relays

RELAY SAFETY 6PST 8A 48V

0

ES-FA-11AA

ES-FA-11AA

Banner Engineering

SAFETY MODULE E-STOP/INTERLOCK

7

1105009

1105009

Phoenix Contact

SAFE EXTENSION MODULE FOR MONITO

32

1319280000

1319280000

Weidmuller

SCS 24VDC P2SIL3ES

416

SFS6-L-DC24V-D

SFS6-L-DC24V-D

Panasonic

RELAY SAFETY 6PST 6A 24V

0

2963718

2963718

Phoenix Contact

RELAY SAFETY DPST 6A 24V

1727

1105010

1105010

Phoenix Contact

SAFE EXTENSION MODULE FOR MONITO

32

ES-FL-2A

ES-FL-2A

Banner Engineering

SAFETY MODULE E-STOP/INTERLOCK

0

SR4M4012

SR4M4012

TE Connectivity Potter & Brumfield Relays

RELAY SAFETY 4PST 8A 12V

1410

RLY3-TIME100

RLY3-TIME100

SICK

SAFETY RELAY CAT 4

8

G7SA-4A2B DC12

G7SA-4A2B DC12

Omron Automation & Safety Services

RELAY SAFETY 6PST 6A 12V

47

UE23-3MF2D2

UE23-3MF2D2

SICK

RELAY SAFETY 4PST 8A 24V

2

SFY5-DC18V

SFY5-DC18V

Panasonic

RELAY SAFETY 6PST 6A 18V

0

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities