Safety Relays

Image Part Number Description / PDF Quantity Rfq
2900526

2900526

Phoenix Contact

RELAY SAFETY DPST 6A 24V

619

V23047-A1006-A501

V23047-A1006-A501

TE Connectivity Potter & Brumfield Relays

RELAY SAFETY DPDT 6A 6V

0

2904951

2904951

Phoenix Contact

RELAY SAFETY SPST 6A 24V

303

RLY3-EMSS1

RLY3-EMSS1

SICK

RELAY SAFETY DPST 6A 24V

14

V23050-A1110-A551

V23050-A1110-A551

TE Connectivity Potter & Brumfield Relays

RELAY SAFETY 6PST 8A 110V

454

UE45-3S13D330

UE45-3S13D330

SICK

RELAY SAFETY 3PST 6A 24V

0

G9SA-TH301 AC100-240

G9SA-TH301 AC100-240

Omron Automation & Safety Services

RELAY SAFETY 3P 120V-240V

0

SF2D-DC5V

SF2D-DC5V

Panasonic

RELAY SAFETY 4PST 6A 5V

0

1104983

1104983

Phoenix Contact

SAFE EXTENSION MODULE WITH 4 SAF

3

1104975

1104975

Phoenix Contact

CONFIGURABLE SAFETY MODULE (BASI

2

ASFM0182X

ASFM0182X

Panasonic

RELAY SAFETY DPST NONC 6A/3A 18V

0

SF3-DC48V

SF3-DC48V

Panasonic

RELAY SAFETY 4PST 6A 48V

0

56.OA11.0631N

56.OA11.0631N

Altech Corporation

OA5611 6V 3NO/1NC AGNI10+2UMAU I

8

SFS4-DC24V

SFS4-DC24V

Panasonic

RELAY SAFETY 6PST 6A 24V

41

SF3-DC24V

SF3-DC24V

Panasonic

RELAY SAFETY 4PST 6A 24V

10

UE11-4DX2D32

UE11-4DX2D32

SICK

RELAY SAFETY 7PST 6A 24V

0

SFS2-L-DC12V-D

SFS2-L-DC12V-D

Panasonic

RELAY SAFETY 4PST 6A 12V

881

SFY4-DC21V

SFY4-DC21V

Panasonic

RELAY SAFETY 6PST 6A 21V

0

G9SB-301-B AC/DC24

G9SB-301-B AC/DC24

Omron Automation & Safety Services

G9SB-301-B AC/DC24

2

SFY2-DC24V

SFY2-DC24V

Panasonic

RELAY SAFETY 4PST 6A 24V

5

Safety Relays

1. Overview

Safety relays are specialized control devices designed to ensure fail-safe operation in industrial systems. They monitor safety-related inputs (e.g., emergency stops, light curtains) and trigger protective actions by cutting power to machinery. Compliant with international standards like IEC 61508 and ISO 13849-1, these relays form the backbone of safety instrumented systems (SIS) across automation sectors.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic Safety RelaysMechanical contact-based design with physical separationMachinery emergency stops, simple safety circuits
Solid-State Safety RelaysZero-contact semiconductor switching with vibration resistancePrecision equipment, explosive atmosphere environments
Programmable Safety RelaysConfigurable logic with diagnostic capabilitiesRobotic cells, complex safety interlocking systems
Monitoring Safety RelaysContinuous circuit integrity verificationSafety door interlocks, two-hand control systems

3. Structure and Components

Typical safety relay construction includes:

  • Enclosure: Flame-retardant polymer housing (UL94 V-0 rated)
  • Coil System: 24V DC/AC operating with bifilar winding for failure detection
  • Contact Arrangement: Gold-plated contacts with positive-guided mechanism
  • Diagnostic Circuitry: Built-in semiconductor for contact state monitoring
  • Mounting Options: DIN rail or PCB mount with screw/clamp terminal connections

4. Key Technical Parameters

ParameterTypical ValueImportance
Safety Integrity Level (SIL)SIL 3 (IEC 61508)Determines risk reduction factor
Response Time5-50 msAffects machine safe stop performance
Contact Rating6A @ 250V ACDictates load switching capability
MTBF500,000 hoursSystem uptime prediction
Environmental Temp-20 C to +55 COperational reliability factor

5. Application Areas

Primary industries include:

  • Industrial Automation: CNC machines, assembly lines
  • Energy Systems: Wind turbine safety circuits
  • Transportation: Rail vehicle door control systems
  • Medical Equipment: MRI machine emergency cutoffs

Case Study: Automotive Press Line Safety

A major automotive manufacturer implemented safety relays in 1200-ton press machines, achieving PLc (EN ISO 13849-1) compliance through dual-channel emergency stop circuits with 35ms response time.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens3SK1 Safety RelayModular design, PROFINET integration
Schneider ElectricXPSM Safety RelayMulti-sensor monitoring, SIL3 capable
OmronG9SP-N Safety ControllerProgrammable with 30 pre-defined safety functions
Phoenix ContactPSR-SCP-24DC-PO Safety RelayPlug-in module with status visualization

7. Selection Guidelines

Critical selection factors:

  • Safety Category: Match to application risk assessment (Cat. 2/3/4)
  • Environmental Conditions: Consider temperature, vibration, and EMC
  • Certifications: Required standards (CE, UL, T V)
  • Expansion Capability: Future system scalability
  • Diagnostic Coverage: Minimum 90% recommended

8. Industry Trends

Emerging developments include:

  • Integration with Industry 4.0 through IO-Link interfaces
  • Functional safety for collaborative robots (cobots)
  • Wireless safety communication protocols
  • Miniaturization while maintaining IP67 ratings
  • AI-enhanced predictive maintenance capabilities
RFQ BOM Call Skype Email
Top