Reed Relays

Image Part Number Description / PDF Quantity Rfq
DAT71215F

DAT71215F

Sensata Technologies – Cynergy3

RELAY REED SPST-NO 2A 12V

14

DBT71210F

DBT71210F

Sensata Technologies – Cynergy3

RELAY REED SPST-NC 2A 12V

4

DAT71210F-HR

DAT71210F-HR

Sensata Technologies – Cynergy3

RELAY REED SPST-NO 2A 12V

0

DAR70510F-HR

DAR70510F-HR

Sensata Technologies – Cynergy3

RELAY REED SPST-NO 3A 5V

12

12HV1B100

12HV1B100

Sensata Technologies – Cynergy3

HV REED RELAY SPST NC 10KV 12V

2

DBR71275FU

DBR71275FU

Sensata Technologies – Cynergy3

RELAY REED SPST-NC 7.5KV 12V

5

DBR71210F-HR

DBR71210F-HR

Sensata Technologies – Cynergy3

RELAY REED SPST-NC 3A 12V

0

DAR72410-HR

DAR72410-HR

Sensata Technologies – Cynergy3

RELAY REED SPST-NO 3A 24V

0

DBR70510-HR

DBR70510-HR

Sensata Technologies – Cynergy3

RELAY REED SPST-NC 3A 5V

0

DBT72410FU

DBT72410FU

Sensata Technologies – Cynergy3

RELAY REED SPST-NC 2A 24V

4

SAR90503

SAR90503

Sensata Technologies – Cynergy3

RELAY REED SPST 500MA 5V

0

DAT200-24

DAT200-24

Sensata Technologies – Cynergy3

RELAY REED SPST-NO 3A 24V

23

TBR212SM

TBR212SM

Sensata Technologies – Cynergy3

RELAY REED SPST-NC 500MA 12V

1

DAT70510U

DAT70510U

Sensata Technologies – Cynergy3

RELAY REED SPST-NO 2A 5V

89

S8-2405VU

S8-2405VU

Sensata Technologies – Cynergy3

RELAY REED SPST 1A 24V UL

0

S1-2404D

S1-2404D

Sensata Technologies – Cynergy3

RELAY REED 4KV SPST 24V SIP W/DI

20

DBR70505FU

DBR70505FU

Sensata Technologies – Cynergy3

RELAY REED SPST-NC 5KV 5V

5

DAT72475FU

DAT72475FU

Sensata Technologies – Cynergy3

RELAY REED SPST-NO 7.5KV 24V

5

DAR70510SU

DAR70510SU

Sensata Technologies – Cynergy3

RELAY REED SPST-NO 3A 5V

0

S8-1204VU

S8-1204VU

Sensata Technologies – Cynergy3

RELAY REED SPST 1A 12V UL

0

Reed Relays

1. Overview

Reed Relays are electromechanical switches comprising a pair of magnetic contacts (reeds) sealed in a glass tube. When a magnetic field generated by a coil actuates the reeds, they flex to make or break an electrical connection. Their hermetic sealing ensures contamination resistance, making them critical in precision applications like automation, telecommunications, and medical devices.

2. Major Types and Functional Classification

TypeFunction FeaturesApplication Examples
SPST (Single Pole Single Throw)Simple on/off switching with one contact pairBasic circuit control in consumer electronics
SPDT (Single Pole Double Throw)Three-terminal switch for circuit redirectionSignal routing in test equipment
DPDT (Double Pole Double Throw)Dual independent circuits with synchronized switchingMotor reversal circuits in industrial machinery
High-Frequency Reed RelaysOptimized for RF/microwave signal integrity5G base station switching modules
High-Power Reed RelaysRated for >10A currents with arc suppressionAutomotive battery management systems

3. Structure and Components

A typical Reed Relay consists of:

  • Glass Enclosure: Hermetic seal with inert gas (N2 or dry air)
  • Contact Blades: Ferromagnetic Ni-Fe alloy with Au or Rh plating
  • Coil Assembly: Copper wire wound on ferrite core for magnetic efficiency
  • Termination Leads: Axial or SMD configurations for PCB mounting

4. Key Technical Specifications

ParameterTypical RangeImportance
Coil Voltage3V-48V DCDetermines actuation power consumption
Contact Current1A-15ADefines load capacity for circuit design
Operate Time0.1ms-5msCritical for high-speed automation
Insulation Resistance>1012 Ensures signal integrity in medical devices
Life Cycle107-109 operationsAffects maintenance intervals in industrial systems

5. Application Fields

Major industries include:

  • Industrial Automation: PLCs, CNC machine controllers
  • Telecommunications: Optical cross-connect systems, RF test equipment
  • Medical Devices: MRI scanner circuitry, lab-on-chip analyzers
  • Automotive: EV charging station contactors, ADAS relay modules
  • Aerospace: Avionics signal switching in flight control systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
TE ConnectivityKILOVAC EV2001500VDC isolation for EV charging
Omron ElectronicsG6K-2P-Y-DC5Ultra-compact DPDT with 200mW coil
Fujitsu ComponentFBR12W-K-C10GHz RF performance for 5G testers
Hamlin by TEHE721-NDMedical-grade isolation for patient monitors

7. Selection Guidelines

Key considerations:

  • Load Type: Resistive vs. inductive loads require different contact materials
  • Switching Speed: Prioritize operate time <1ms for data acquisition systems
  • Environmental Factors: Select IP67-rated models for automotive under-hood applications
  • Mounting: Use SMD relays for automated PCB assembly
  • Cost vs. Longevity: High-endurance models may reduce lifetime maintenance costs

8. Industry Trends

Emerging developments:

  • Miniaturization: 0402 package reed relays for wearable medical devices
  • Integration: Smart relays with built-in coil suppression circuits
  • Material Innovation: Graphene-coated contacts for 10x lifespan improvement
  • Wireless Control: BLE-enabled reed relay modules for IoT applications
  • High-Temperature Performance: Relays operational up to 150 C for EV powertrains

RFQ BOM Call Skype Email