Power Relays, Over 2 Amps

Image Part Number Description / PDF Quantity Rfq
FCAV-410-BZ4

FCAV-410-BZ4

TE Connectivity Aerospace Defense and Marine

FCAV-410-BZ4=4PDT 10A MID-RANGE

0

7-1617787-3

7-1617787-3

TE Connectivity Aerospace Defense and Marine

FCB-405-0631M=M83536/6-031M

0

5-1617785-0

5-1617785-0

TE Connectivity Aerospace Defense and Marine

FCA-410-1516M=M83536/15-016M

0

4-1617041-1

4-1617041-1

TE Connectivity Aerospace Defense and Marine

RP7641G332 = 2000-F RELAY

0

9-1616930-6

9-1616930-6

TE Connectivity Aerospace Defense and Marine

A703WA=RELAY

0

4-1618007-8

4-1618007-8

TE Connectivity Aerospace Defense and Marine

AP5AB47=RELAY, VACUUM, SPST-NO

0

2-1617785-6

2-1617785-6

TE Connectivity Aerospace Defense and Marine

FCA-410-1504L=M83536/15-004L

0

9-1617748-5

9-1617748-5

TE Connectivity Aerospace Defense and Marine

FCA-210-0922L=M83536/9-022L

0

1617778-9

1617778-9

TE Connectivity Aerospace Defense and Marine

B07B935BZ1-1043=10 AMP FULL SIZE

0

K81B545

K81B545

TE Connectivity Aerospace Defense and Marine

K81B545=RELAY, VACUUM, SPST-NC

0

FM200DBY

FM200DBY

TE Connectivity Aerospace Defense and Marine

FM200DBY=RELAY, SPST-NC, 24 VDC

0

4-1617786-2

4-1617786-2

TE Connectivity Aerospace Defense and Marine

FCB-205-0213L=M83536/2-013L

0

5-1617785-6

5-1617785-6

TE Connectivity Aerospace Defense and Marine

FCA-410-1520L=M83536/15-020L

0

8-1617755-6

8-1617755-6

TE Connectivity Aerospace Defense and Marine

FCA-410-BW3

0

FCA-125-4

FCA-125-4

TE Connectivity Aerospace Defense and Marine

FCA-125-4=M6106/19-004

0

FCB-205-0104M

FCB-205-0104M

TE Connectivity Aerospace Defense and Marine

FCB-205-0104M=M83536/1-004M

0

SF5A53145S01

SF5A53145S01

TE Connectivity Aerospace Defense and Marine

SF5A53145S01=SENSITIVE FULL SIZE

0

4-1617058-0

4-1617058-0

TE Connectivity Aerospace Defense and Marine

41RZ-95846 = RELAY,ELECTROMAGN

0

4-1617003-6

4-1617003-6

TE Connectivity Aerospace Defense and Marine

B07B939BZ1-0869 = 07 RELAY.

0

2-1617786-4

2-1617786-4

TE Connectivity Aerospace Defense and Marine

FCB-205-0202L=M83536/2-002L

0

Power Relays, Over 2 Amps

1. Overview

Power relays with switching capabilities over 2 amps are electromechanical or solid-state devices designed to control high-current electrical circuits through low-power signals. These components play a critical role in modern automation systems, industrial machinery, and energy management solutions by enabling safe and reliable control of heavy loads. Their importance stems from their ability to isolate control circuits from high-power circuits, ensuring operational safety and system longevity in demanding applications.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Electromagnetic RelaysMechanical switching via magnetic coil activation, typical current range 2-20AIndustrial machinery control systems
Solid-State Relays (SSR)Semiconductor-based switching with zero-noise operation, 2-100A capacityTemperature control in manufacturing equipment
High-Power RelaysHeavy-duty contacts with reinforced insulation, 10-100A+ ratingsElectric vehicle charging stations
PCB Mount RelaysMiniaturized designs for printed circuit board integration, 2-15ASmart home automation systems
Panel Mount RelaysRail-mountable industrial grade units with visual contact indicatorsFactory automation control panels

3. Structure and Components

Standard power relays above 2A typically consist of: - Electromagnetic System: Copper coil wound around laminated iron core - Contact Assembly: Silver alloy contacts (AgSnO2 or AgCdO) with arc suppression - Magnetic Circuit: Optimized flux path design with magnetic shielding - Encapsulation: Flame-retardant thermoplastic housing (UL94 V-0 rated) - Terminals: Screw-type or quick-connect terminals (250V/16A rating minimum)

4. Key Technical Specifications

ParameterTypical RangeImportance
Rated Current2-100ADetermines load handling capability
Switching Voltage5-600V AC/DCDefines circuit compatibility
Coil Voltage3-250VAffects control circuit design
Contact MaterialAgSnO2, AgCdOImpacts wear resistance and contact resistance
Electrical Life10^5 - 10^6 operationsDictates maintenance intervals
Mounting TypePCB, Panel, DIN RailImpacts system integration
Operating Temp-40 C to +85 CDefines environmental tolerance

5. Application Fields

Key industries utilizing these relays include: - Industrial Automation: PLC-controlled assembly lines, CNC machines - Energy Systems: Smart grid relays, solar inverters - Transportation: EV battery management, railway signaling - Building Systems: HVAC control, emergency lighting - Consumer Electronics: High-power home appliances

Case Study: In automotive production lines, 30A power relays control robotic arm actuators, with solid-state variants managing precise welding current switching.

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
OmronMY2 AC-DC10A rating, LED status indicator, 5kV isolation
Schneider ElectricLC1D099-32A adjustable range, 660V withstand voltage
TE ConnectivityPotter & Brumfield80A high-power relays with silver contacts
Siemens3RT10Industrial SSRs with 0.1ms response time
Phoenix ContactPSR-SCPPlug-in power relays with diagnostic LEDs

7. Selection Recommendations

Key selection criteria: - Load Type: Resistive vs. inductive loads require different derating factors (inductive loads need 20-30% capacity margin) - Environmental Factors: Humidity, vibration, and temperature extremes affect reliability - Switching Frequency: High-cycle applications (>1000 ops/hr) require silver-palladium contacts - Agency Approvals: Check for UL, CSA, or IEC certifications - Installation Space: PCB size constraints vs. panel-mount accessibility

Recommendation: For 12V DC motor control in outdoor equipment, select a sealed 15A relay with IP67 rating and gold-plated contacts.

8. Industry Trends

Emerging developments include: - Miniaturization: 30% size reduction in 5A relays (2020-2023) - Smart Integration: Relays with embedded IoT communication modules - Energy Efficiency: Coil power consumption below 0.2W for 10A relays - Material Innovation: Cadmium-free contact materials (EU RoHS compliance) - Hybrid Solutions: Electromechanical relays with integrated solid-state pre-switching - Predictive Maintenance: Relays with built-in wear-out sensors and lifetime monitoring

RFQ BOM Call Skype Email
Top