Power Relays, Over 2 Amps

Image Part Number Description / PDF Quantity Rfq
1123630000

1123630000

Weidmuller

TRZ 48VUC 2CO

0

1123780000

1123780000

Weidmuller

TRS 120VUC 2CO AU

0

8920970000

8920970000

Weidmuller

RELAY GEN PURPOSE DPDT 12A 230V

0

4074580000

4074580000

Weidmuller

RCL425012

0

1113661001

1113661001

Weidmuller

RELAY SPDT 8A 24VDC DIN

0

EA20507

EA20507

Weidmuller

RSML-R 16/5V TTL SPDT 6A RLY

0

7760056094

7760056094

Weidmuller

DRM570615L

0

8713760000

8713760000

Weidmuller

RIM 3 24/60VUC GN

0

8556130000

8556130000

Weidmuller

RELAY GEN PURPOSE SPDT 6A 60V

0

1220060000

1220060000

Weidmuller

DRH275048LT

0

1174650000

1174650000

Weidmuller

RIM 5 6/230VDC

0

1219390000

1219390000

Weidmuller

DRW270900LT

0

7940006160

7940006160

Weidmuller

RCLKIT 230VAC 1CO LED RT

0

1219940000

1219940000

Weidmuller

DRH174012LT

0

1220200000

1220200000

Weidmuller

DRH276524LT

0

8691000000

8691000000

Weidmuller

RIM 3 110/230VAC

0

1123020000

1123020000

Weidmuller

TRS 48VUC 1CO AU

0

7760056188

7760056188

Weidmuller

DRM570730L AU

0

1133580000

1133580000

Weidmuller

DRL370024L

0

7760056271

7760056271

Weidmuller

DRM270524/2CO/24VAC FLASH GOLD

0

Power Relays, Over 2 Amps

1. Overview

Power relays with switching capabilities over 2 amps are electromechanical or solid-state devices designed to control high-current electrical circuits through low-power signals. These components play a critical role in modern automation systems, industrial machinery, and energy management solutions by enabling safe and reliable control of heavy loads. Their importance stems from their ability to isolate control circuits from high-power circuits, ensuring operational safety and system longevity in demanding applications.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Electromagnetic RelaysMechanical switching via magnetic coil activation, typical current range 2-20AIndustrial machinery control systems
Solid-State Relays (SSR)Semiconductor-based switching with zero-noise operation, 2-100A capacityTemperature control in manufacturing equipment
High-Power RelaysHeavy-duty contacts with reinforced insulation, 10-100A+ ratingsElectric vehicle charging stations
PCB Mount RelaysMiniaturized designs for printed circuit board integration, 2-15ASmart home automation systems
Panel Mount RelaysRail-mountable industrial grade units with visual contact indicatorsFactory automation control panels

3. Structure and Components

Standard power relays above 2A typically consist of: - Electromagnetic System: Copper coil wound around laminated iron core - Contact Assembly: Silver alloy contacts (AgSnO2 or AgCdO) with arc suppression - Magnetic Circuit: Optimized flux path design with magnetic shielding - Encapsulation: Flame-retardant thermoplastic housing (UL94 V-0 rated) - Terminals: Screw-type or quick-connect terminals (250V/16A rating minimum)

4. Key Technical Specifications

ParameterTypical RangeImportance
Rated Current2-100ADetermines load handling capability
Switching Voltage5-600V AC/DCDefines circuit compatibility
Coil Voltage3-250VAffects control circuit design
Contact MaterialAgSnO2, AgCdOImpacts wear resistance and contact resistance
Electrical Life10^5 - 10^6 operationsDictates maintenance intervals
Mounting TypePCB, Panel, DIN RailImpacts system integration
Operating Temp-40 C to +85 CDefines environmental tolerance

5. Application Fields

Key industries utilizing these relays include: - Industrial Automation: PLC-controlled assembly lines, CNC machines - Energy Systems: Smart grid relays, solar inverters - Transportation: EV battery management, railway signaling - Building Systems: HVAC control, emergency lighting - Consumer Electronics: High-power home appliances

Case Study: In automotive production lines, 30A power relays control robotic arm actuators, with solid-state variants managing precise welding current switching.

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
OmronMY2 AC-DC10A rating, LED status indicator, 5kV isolation
Schneider ElectricLC1D099-32A adjustable range, 660V withstand voltage
TE ConnectivityPotter & Brumfield80A high-power relays with silver contacts
Siemens3RT10Industrial SSRs with 0.1ms response time
Phoenix ContactPSR-SCPPlug-in power relays with diagnostic LEDs

7. Selection Recommendations

Key selection criteria: - Load Type: Resistive vs. inductive loads require different derating factors (inductive loads need 20-30% capacity margin) - Environmental Factors: Humidity, vibration, and temperature extremes affect reliability - Switching Frequency: High-cycle applications (>1000 ops/hr) require silver-palladium contacts - Agency Approvals: Check for UL, CSA, or IEC certifications - Installation Space: PCB size constraints vs. panel-mount accessibility

Recommendation: For 12V DC motor control in outdoor equipment, select a sealed 15A relay with IP67 rating and gold-plated contacts.

8. Industry Trends

Emerging developments include: - Miniaturization: 30% size reduction in 5A relays (2020-2023) - Smart Integration: Relays with embedded IoT communication modules - Energy Efficiency: Coil power consumption below 0.2W for 10A relays - Material Innovation: Cadmium-free contact materials (EU RoHS compliance) - Hybrid Solutions: Electromechanical relays with integrated solid-state pre-switching - Predictive Maintenance: Relays with built-in wear-out sensors and lifetime monitoring

RFQ BOM Call Skype Email