I/O Relay Modules

Image Part Number Description / PDF Quantity Rfq
IAC5Q

IAC5Q

Sensata Technologies – Crydom

AC INPUT MODULE 120V

0

OAC5Q

OAC5Q

Sensata Technologies – Crydom

AC OUTPUT MODULE 3A

0

G3TC-OAC5 DC5

G3TC-OAC5 DC5

Omron Automation & Safety Services

AC OUTPUT MODULE 3A

0

SM-ODC5A

SM-ODC5A

Sensata Technologies – Crydom

DC OUTPUT MODULE 1A

0

ODC24A

ODC24A

Sensata Technologies – Crydom

DC OUTPUT MODULE 1A

0

M-IAC15

M-IAC15

Sensata Technologies – Crydom

AC INPUT MODULE 120V

0

73G-II5000

73G-II5000

Grayhill, Inc.

ANALOG INPUT MODULE

0

G3TC-IDC5 DC/AC 24

G3TC-IDC5 DC/AC 24

Omron Automation & Safety Services

DC INPUT MODULE 24V

0

73G-IV10

73G-IV10

Grayhill, Inc.

ANALOG INPUT MODULE

0

73G-OI420

73G-OI420

Grayhill, Inc.

ANALOG OUTPUT MODULE

0

SM-ODC24A

SM-ODC24A

Sensata Technologies – Crydom

DC OUTPUT MODULE 1A

0

DMP6402A

DMP6402A

Sensata Technologies – Crydom

AC OUTPUT MODULE 3A

0

M-ODC15A

M-ODC15A

Sensata Technologies – Crydom

DC OUTPUT MODULE 1A

0

OAC4/15-L

OAC4/15-L

Panasonic

AC OUTPUT MODULE 2A

0

SM-OAC24A

SM-OAC24A

Sensata Technologies – Crydom

AC OUTPUT MODULE 3.5A

0

SM-IAC24A

SM-IAC24A

Sensata Technologies – Crydom

AC INPUT MODULE 240V

0

M-OAC15

M-OAC15

Sensata Technologies – Crydom

AC OUTPUT MODULE 3A

0

73G-IV100M

73G-IV100M

Grayhill, Inc.

ANALOG INPUT MODULE

0

70L-IDCG

70L-IDCG

Grayhill, Inc.

AC/DC INPUT MODULE 35-60V

0

G3TC-ODC5 DC5

G3TC-ODC5 DC5

Omron Automation & Safety Services

DC OUTPUT MODULE 3A

0

I/O Relay Modules

1. Overview

I/O Relay Modules (Input/Output Relay Modules) are electronic devices that enable signal conversion and electrical isolation between control systems and external equipment. They act as intermediaries to control high-power circuits using low-power signals, playing a critical role in automation systems, industrial machinery, and smart infrastructure. These modules ensure safe and reliable switching operations in applications ranging from factory automation to renewable energy systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic RelaysMechanical switching via electromagnetic coils, high current capacityIndustrial motor control, HVAC systems
Solid-State Relays (SSR)No moving parts, fast switching, low EMITemperature control systems, semiconductor equipment
Hybrid RelaysCombines electromagnetic and solid-state advantagesPrecision manufacturing, aerospace systems
Programmable RelaysUser-configurable logic functionsCustom automation systems, R&D equipment
Smart RelaysIntegrated sensors, IoT connectivity, self-diagnosisSmart grids, predictive maintenance systems

3. Structure and Components

A typical I/O Relay Module consists of:

  • Housing: Flame-retardant polymer casing (UL 94 V-0 rated)
  • Contact System: Silver alloy for low resistance (AgSnO typical)
  • Coil Assembly: Copper winding with thermal class F insulation
  • Drive Circuitry: Transistor-based drivers for DC types or zero-crossing detection for AC
  • Isolation Layer: Reinforced insulation barrier (2500 Vrms basic insulation)

4. Key Technical Specifications

ParameterSignificanceTypical Range
Rated VoltageDetermines application circuit compatibility5VDC-250VAC
Current RatingAffects power handling capability1A-100A
Switching SpeedCritical for real-time control systems0.5ms-20ms
Electrical LifeDirectly impacts maintenance intervals10 - 10 operations
Insulation ResistanceEnsures safety isolation>100M @ 500VDC

5. Application Areas

  • Industrial Automation: PLC systems, assembly line robots
  • Energy Systems: Smart grid controllers, solar inverters
  • Transportation: Railway signaling, EV charging stations
  • Medical Equipment: Diagnostic imaging systems, infusion pumps

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
OmronMY2N-J30A rating, LED status indicator
SiemensSIMATIC ET 200PROFINET interface, hot-swappable
Schneider ElectricZelio SR2Programmable, LCD display
ABBAF250-30LEnergy-efficient coil, 125kHz switching
Phoenix ContactPSR-SCP-24DC-CTSafe separation, configurable delay

7. Selection Recommendations

Key considerations include:

  • Match voltage/current ratings with load requirements (125% safety margin recommended)
  • Environmental factors: operating temperature (-40 C to +85 C typical)
  • Mounting type: PCB, DIN rail, or panel mount
  • Communication protocol compatibility (Modbus, EtherCAT, etc.)
  • Failure Mode Analysis: Choose failsafe configuration per application needs

8. Industry Trends

Emerging developments include:

  • Integration with IIoT protocols (OPC UA, MQTT)
  • Miniaturization: 30% size reduction in 2023 models
  • Energy efficiency improvements: >85% coil power reduction
  • AI-enabled predictive maintenance features
  • Increased adoption of wide bandgap semiconductors in SSRs

Application Case Study

A automotive manufacturing plant implemented Omron MY4NJ relays in robotic welding systems, achieving:

  • 40% reduction in switching-related downtime
  • 25% energy savings through optimized coil drive
  • Integration with existing PROFINET network
RFQ BOM Call Skype Email
Top