I/O Relay Modules

Image Part Number Description / PDF Quantity Rfq
70L-ODC5R

70L-ODC5R

Grayhill, Inc.

DC OUTPUT MODULE 500MA

0

70G-ODC24B

70G-ODC24B

Grayhill, Inc.

DC OUTPUT MODULE 3.5A

6

RIM-OAC15A

RIM-OAC15A

NTE Electronics, Inc.

AC OUTPUT MODULE 15V

3

6321

6321

Sensata Technologies – Crydom

DC OUTPUT MODULE 3.5A

0

70M-IDC5

70M-IDC5

Grayhill, Inc.

DC INPUT MODULE 3-32V

18

70M-ODC5A

70M-ODC5A

Grayhill, Inc.

DC OUTPUT MODULE 3A

405

70M-OAC5

70M-OAC5

Grayhill, Inc.

AC OUTPUT MODULE 3A

110

70-IAC24

70-IAC24

Grayhill, Inc.

AC INPUT MODULE 120V

10

RIM-IAC5A

RIM-IAC5A

NTE Electronics, Inc.

AC INPUT MODULE 5V

56

RIM-IAC24A

RIM-IAC24A

NTE Electronics, Inc.

AC INPUT MODULE 24V

20

70-OAC5A

70-OAC5A

Grayhill, Inc.

AC OUTPUT MODULE 3.5A

139

RIM-OAC15AM

RIM-OAC15AM

NTE Electronics, Inc.

SLIM LINE OUTPUT MOD 15V

68

G3TA-OA202SZ-US DC12

G3TA-OA202SZ-US DC12

Omron Automation & Safety Services

AC OUTPUT MODULE 2A

17

RIM-IAC15AM

RIM-IAC15AM

NTE Electronics, Inc.

SLIM LINE INPUT MOD 15V

78

70M-OAC24A

70M-OAC24A

Grayhill, Inc.

AC OUTPUT MODULE 3A

0

IAC24

IAC24

Sensata Technologies – Crydom

AC INPUT MODULE 120V

0

70G-IAC24

70G-IAC24

Grayhill, Inc.

AC INPUT MODULE 120V

23

G3R-OA202SZN DC5-24

G3R-OA202SZN DC5-24

Omron Automation & Safety Services

AC OUTPUT MODULE 2A

49

70-IDC5

70-IDC5

Grayhill, Inc.

DC INPUT MODULE 3-32V

135

RIM-ODC15

RIM-ODC15

NTE Electronics, Inc.

DC OUTPUT MODULE 15V

2

I/O Relay Modules

1. Overview

I/O Relay Modules (Input/Output Relay Modules) are electronic devices that enable signal conversion and electrical isolation between control systems and external equipment. They act as intermediaries to control high-power circuits using low-power signals, playing a critical role in automation systems, industrial machinery, and smart infrastructure. These modules ensure safe and reliable switching operations in applications ranging from factory automation to renewable energy systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Electromagnetic RelaysMechanical switching via electromagnetic coils, high current capacityIndustrial motor control, HVAC systems
Solid-State Relays (SSR)No moving parts, fast switching, low EMITemperature control systems, semiconductor equipment
Hybrid RelaysCombines electromagnetic and solid-state advantagesPrecision manufacturing, aerospace systems
Programmable RelaysUser-configurable logic functionsCustom automation systems, R&D equipment
Smart RelaysIntegrated sensors, IoT connectivity, self-diagnosisSmart grids, predictive maintenance systems

3. Structure and Components

A typical I/O Relay Module consists of:

  • Housing: Flame-retardant polymer casing (UL 94 V-0 rated)
  • Contact System: Silver alloy for low resistance (AgSnO typical)
  • Coil Assembly: Copper winding with thermal class F insulation
  • Drive Circuitry: Transistor-based drivers for DC types or zero-crossing detection for AC
  • Isolation Layer: Reinforced insulation barrier (2500 Vrms basic insulation)

4. Key Technical Specifications

ParameterSignificanceTypical Range
Rated VoltageDetermines application circuit compatibility5VDC-250VAC
Current RatingAffects power handling capability1A-100A
Switching SpeedCritical for real-time control systems0.5ms-20ms
Electrical LifeDirectly impacts maintenance intervals10 - 10 operations
Insulation ResistanceEnsures safety isolation>100M @ 500VDC

5. Application Areas

  • Industrial Automation: PLC systems, assembly line robots
  • Energy Systems: Smart grid controllers, solar inverters
  • Transportation: Railway signaling, EV charging stations
  • Medical Equipment: Diagnostic imaging systems, infusion pumps

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
OmronMY2N-J30A rating, LED status indicator
SiemensSIMATIC ET 200PROFINET interface, hot-swappable
Schneider ElectricZelio SR2Programmable, LCD display
ABBAF250-30LEnergy-efficient coil, 125kHz switching
Phoenix ContactPSR-SCP-24DC-CTSafe separation, configurable delay

7. Selection Recommendations

Key considerations include:

  • Match voltage/current ratings with load requirements (125% safety margin recommended)
  • Environmental factors: operating temperature (-40 C to +85 C typical)
  • Mounting type: PCB, DIN rail, or panel mount
  • Communication protocol compatibility (Modbus, EtherCAT, etc.)
  • Failure Mode Analysis: Choose failsafe configuration per application needs

8. Industry Trends

Emerging developments include:

  • Integration with IIoT protocols (OPC UA, MQTT)
  • Miniaturization: 30% size reduction in 2023 models
  • Energy efficiency improvements: >85% coil power reduction
  • AI-enabled predictive maintenance features
  • Increased adoption of wide bandgap semiconductors in SSRs

Application Case Study

A automotive manufacturing plant implemented Omron MY4NJ relays in robotic welding systems, achieving:

  • 40% reduction in switching-related downtime
  • 25% energy savings through optimized coil drive
  • Integration with existing PROFINET network
RFQ BOM Call Skype Email
Top