I/O Relay Module Racks

Image Part Number Description / PDF Quantity Rfq
2962382

2962382

Phoenix Contact

I/O MODULE RACK CHANNEL

0

2972851

2972851

Phoenix Contact

I/O MODULE RACK CHANNEL

0

70GRCK16I-DIN

70GRCK16I-DIN

Grayhill, Inc.

I/O MODULE RACK 16 CHANNEL

0

PB-8M-C

PB-8M-C

Sensata Technologies – Crydom

I/O MODULE RACK 8 CHANNEL

0

PB-24M

PB-24M

Sensata Technologies – Crydom

I/O MODULE RACK 24 CHANNEL

0

PB-24M-C

PB-24M-C

Sensata Technologies – Crydom

I/O MODULE RACK 24 CHANNEL

0

PB-4C4

PB-4C4

Sensata Technologies – Crydom

I/O MODULE RACK 4 CHANNEL

0

MS-8H

MS-8H

Sensata Technologies – Crydom

I/O MODULE RACK 8 CHANNEL

0

2970882

2970882

Phoenix Contact

I/O MODULE RACK 4 CHANNEL

0

2972945

2972945

Phoenix Contact

I/O MODULE RACK CHANNEL

0

PB-32Q

PB-32Q

Sensata Technologies – Crydom

I/O MODULE RACK 32 CHANNEL

0

70LRCK24-HL

70LRCK24-HL

Grayhill, Inc.

I/O MODULE RACK 24 CHANNEL

0

PB-8

PB-8

Sensata Technologies – Crydom

I/O MODULE RACK 8 CHANNEL

0

70GRCM32-HL

70GRCM32-HL

Grayhill, Inc.

I/O MODULE RACK 32 CHANNEL

0

PB-24Q

PB-24Q

Sensata Technologies – Crydom

I/O MODULE RACK 24 CHANNEL

0

PB-24SM

PB-24SM

Sensata Technologies – Crydom

I/O MODULE RACK 24 CHANNEL

0

PB-16T

PB-16T

Sensata Technologies – Crydom

I/O MODULE RACK 16 CHANNEL

0

PB-16

PB-16

Sensata Technologies – Crydom

I/O MODULE RACK 16 CHANNEL

0

PB-16C4

PB-16C4

Sensata Technologies – Crydom

I/O MODULE RACK 16 CHANNEL

0

PB-24M-V

PB-24M-V

Sensata Technologies – Crydom

I/O MODULE RACK 24 CHANNEL

0

I/O Relay Module Racks

I/O Relay Module Racks are industrial control system components that serve as interface units between programmable logic controllers (PLCs) and field devices. They provide modularized signal conversion, isolation, and distribution functions for digital/analog input/output operations. These racks enable efficient integration of sensors, actuators, and automation equipment in complex industrial environments, playing a critical role in Industry 4.0 and smart manufacturing systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Digital I/O ModulesDiscrete signal switching (24VDC/230VAC), high-speed counting capabilitiesMachine safety systems, conveyor belt controls
Analog I/O ModulesSignal conditioning (4-20mA/0-10V), precision measurement ( 0.1% accuracy)Process temperature control, pressure monitoring
Mixed I/O ModulesIntegrated digital/analog channels with galvanic isolationCompact control panels for packaging machinery
Intelligent I/O ModulesEmbedded processing (PID control), protocol conversion (PROFINET/Modbus)Decentralized automation systems in automotive plants

3. Structure and Components

Standard I/O relay racks feature a DIN-rail mounted aluminum housing with modular slot architecture. Key components include:

  • Hot-swappable module bays (typically 8-16 slots)
  • Backplane bus system with 32-bit data width
  • Redundant power supplies (24VDC/115-230VAC options)
  • Terminal blocks with screw/clamp connections
  • LED status indicators per channel
  • Integrated heat dissipation channels

4. Key Technical Specifications

ParameterValue RangeImportance
Channel Density4-64 channels/rackDetermines system scalability
Voltage Range12-480VAC/DCAffects device compatibility
Response Time0.1ms-10msCritical for high-speed applications
Operating Temp.-40 C to +70 CEnvironmental reliability
IP RatingIP20 (standard) to IP67Dust/liquid protection level
Communication ProtocolsPROFINET, EtherCAT, Modbus TCPSystem integration capability

5. Application Fields

Major industries utilizing I/O relay racks include:

  • Manufacturing: Assembly lines, robotic welding cells
  • Energy: SCADA systems for grid monitoring
  • Process Control: Chemical reactor automation
  • Transportation: Rail signaling and HVAC control
  • Building Automation: BMS systems for smart buildings

Typical equipment integration: Siemens S7-1500 PLC systems, Allen Bradley GuardLogix controllers

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
SiemensET 200SP HAIP67 rated, 24VDC operation, PROFINET interface
HoneywellExperion LX I/OHazardous area certification, redundant architecture
OmronNX SeriesCompact design, EtherCAT compatibility
AdvantechADAM-5000Modbus TCP support, wide temperature range

7. Selection Recommendations

Key selection criteria:

  1. Signal type requirements (digital/analog/mixed)
  2. Environmental conditions (temperature, humidity, vibration)
  3. System compatibility (PLC brand, communication protocols)
  4. Expansion needs (modular vs fixed configuration)
  5. Redundancy requirements (critical process control applications)

Case Study: An automotive plant selected Phoenix Contact's Axioline I/O system with IP67 rating for underbody painting robots, achieving 99.98% uptime in corrosive environments.

Industry Development Trends

Future development directions include:

  • Integration of AI-based predictive maintenance
  • Expansion of TSN (Time-Sensitive Networking) support
  • Increased cybersecurity features (IEC 62443 compliance)
  • Miniaturization with higher channel density
  • Growing adoption of wireless I/O modules

Market forecasts indicate 7.2% CAGR through 2030, driven by smart factory investments and Industry 4.0 initiatives globally.