Contactors (Electromechanical)

Image Part Number Description / PDF Quantity Rfq
J7KN-32 24D

J7KN-32 24D

Omron Automation & Safety Services

MOTOR CONTACTOR 32A 24VDC COIL

0

J7KN-316 110

J7KN-316 110

Omron Automation & Safety Services

CONTR,310A,3POLE,AC110/120

0

J7KN-74 24D

J7KN-74 24D

Omron Automation & Safety Services

RELAY CONTACTOR 74A 24V

0

G7Z-2A2B DC24

G7Z-2A2B DC24

Omron Automation & Safety Services

RELAY GEN PURPOSE 4PST 40A 24V

6

J7KNA-09-01R 110

J7KNA-09-01R 110

Omron Automation & Safety Services

CONTR,9A,0NO,1NC,R,AC110/(120)

0

G7Z-2A2B-11Z-R DC24V

G7Z-2A2B-11Z-R DC24V

Omron Automation & Safety Services

RELAY GEN PURPOSE 4PST 40A 24V

0

G7Z-3A1B-02Z-R DC12V

G7Z-3A1B-02Z-R DC12V

Omron Automation & Safety Services

RELAY GEN PURPOSE 4PST 40A 12V

0

J7KN-32 230

J7KN-32 230

Omron Automation & Safety Services

RELAY CONTACTOR 32A 230V

0

J7KN-40 24D

J7KN-40 24D

Omron Automation & Safety Services

CONTACTOR

0

G7Z-2A2B-11Z-R DC12V

G7Z-2A2B-11Z-R DC12V

Omron Automation & Safety Services

RELAY GEN PURPOSE 4PST 40A 12V

0

J7KN-10D-10 110

J7KN-10D-10 110

Omron Automation & Safety Services

CONTACTOR

0

J7KN-22D-10 24D

J7KN-22D-10 24D

Omron Automation & Safety Services

CONTACTOR

0

J7KN-10D-01 48

J7KN-10D-01 48

Omron Automation & Safety Services

CONTACTOR

0

J7KN-32 500

J7KN-32 500

Omron Automation & Safety Services

CONTACTOR

0

J7KN-10D-10 230

J7KN-10D-10 230

Omron Automation & Safety Services

CONTACTOR

0

J7KN-151-4 110

J7KN-151-4 110

Omron Automation & Safety Services

CONTR,150A,4POLE,AC110/120

0

J7KNG-22-01 24D

J7KNG-22-01 24D

Omron Automation & Safety Services

CONTACTOR

0

J7KNG-10-10 24D

J7KNG-10-10 24D

Omron Automation & Safety Services

RELAY CONTACTOR 3PST 10A 24V

0

J7KN-22D-10 180

J7KN-22D-10 180

Omron Automation & Safety Services

CONTACTOR

0

J7KN-22D-10 110

J7KN-22D-10 110

Omron Automation & Safety Services

3 POLE 22A 110V

0

Contactors (Electromechanical)

1. Overview

Electromechanical contactors are electrically controlled switching devices designed to handle high-current loads. They operate through electromagnetic actuation to open or close contacts, enabling remote control of electrical circuits. These components are critical in industrial automation, power distribution, and motor control systems, offering reliable and scalable solutions for managing electrical loads ranging from kilowatts to megawatts.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
AC ContactorsDesigned for alternating current loads with arc suppression featuresMotor starters, HVAC systems
DC ContactorsOptimized for direct current circuits with magnetic blowout arcsElectric vehicle charging, battery systems
Heavy-Duty ContactorsHigh inrush current tolerance with reinforced contactsIndustrial furnaces, large compressors
Vacuum ContactorsUse vacuum as arc-quenching medium for high-voltage applicationsPower generation systems, traction equipment

3. Structure and Components

Typical construction includes:

  • Electromagnetic actuator (coil and iron core)
  • Main contacts (silver alloy for conductivity)
  • Auxiliary contacts (for control circuits)
  • Arc suppression system (grids or vacuum chambers)
  • Mechanical linkage assembly

4. Key Technical Parameters

ParameterSignificance
Rated operational current (Ie)Determines maximum load capacity
Rated voltage (Ue)Defines operating voltage range
Coil power consumptionAffects control circuit design
Mechanical life (cycles)Indicates durability without maintenance
Short-circuit withstandSafety margin for fault conditions

5. Application Fields

Primary industries include:

  • Industrial automation (motor control centers)
  • Power generation and distribution systems
  • Building HVAC equipment
  • Transportation infrastructure (traction systems)
  • Agricultural machinery (irrigation pumps)

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
Schneider ElectricTeSys D Green Contactors
Siemens3RT12xx series
ABBAF110-30LX vacuum contactor
OmronMY22S DC contactor

7. Selection Guidelines

Key considerations:

  • Load type (resistive/inductive) and inrush current
  • Environmental conditions (temperature, vibration)
  • Control voltage compatibility
  • Mounting orientation and space constraints
  • Certification requirements (IEC 61439, UL 508)
Example: For 400A motor control in a foundry, select a heavy-duty contactor with IP54 rating and class F insulation.

8. Industry Trends

Emerging developments:

  • Integration with IoT-enabled monitoring systems
  • Nano-coating technologies for harsh environments
  • Miniaturization through advanced arc suppression
  • Hybrid designs combining solid-state and electromechanical features
  • Eco-friendly materials reducing rare metal dependency

RFQ BOM Call Skype Email
Top