Contactors (Electromechanical)

Image Part Number Description / PDF Quantity Rfq
4-1618391-1

4-1618391-1

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 100A 24V

7

EV200GAANA

EV200GAANA

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 500A 12V

31

EV200HAANA

EV200HAANA

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 500A 12V

86

K400A1F

K400A1F

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 400A 28VDC

0

LEV200A4ANA

LEV200A4ANA

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 500A 12V

33

LEV200A4NAA

LEV200A4NAA

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 500A 12V

93

LEV200A5NAA

LEV200A5NAA

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 500A 24V

291

EV200ADANA

EV200ADANA

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 500A 48V

3

K400B1F

K400B1F

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 400A 28VDC

0

EV202MSAND

EV202MSAND

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR DPST 350A 24V

1

EV100AAANA

EV100AAANA

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 100A 36V

122

7-1618387-2

7-1618387-2

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 500A 24V

3

LEV200A4NAF01

LEV200A4NAF01

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 500A 12V

45

LEV100H5CNG

LEV100H5CNG

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 100A 24V

47

EV202ASAND

EV202ASAND

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR DPST 350A 24V

0

5-1618388-8

5-1618388-8

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 500A 48V

35

CAP120ASANG

CAP120ASANG

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 150A 28V

20

KCS03X024EAAA

KCS03X024EAAA

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 600A 24V

0

D7M

D7M

TE Connectivity Aerospace Defense and Marine

D7M=RELAY

0

LEV100A4ANH

LEV100A4ANH

TE Connectivity Aerospace Defense and Marine

RELAY CONTACTOR SPST 100A 12V

82

Contactors (Electromechanical)

1. Overview

Electromechanical contactors are electrically controlled switching devices designed to handle high-current loads. They operate through electromagnetic actuation to open or close contacts, enabling remote control of electrical circuits. These components are critical in industrial automation, power distribution, and motor control systems, offering reliable and scalable solutions for managing electrical loads ranging from kilowatts to megawatts.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
AC ContactorsDesigned for alternating current loads with arc suppression featuresMotor starters, HVAC systems
DC ContactorsOptimized for direct current circuits with magnetic blowout arcsElectric vehicle charging, battery systems
Heavy-Duty ContactorsHigh inrush current tolerance with reinforced contactsIndustrial furnaces, large compressors
Vacuum ContactorsUse vacuum as arc-quenching medium for high-voltage applicationsPower generation systems, traction equipment

3. Structure and Components

Typical construction includes:

  • Electromagnetic actuator (coil and iron core)
  • Main contacts (silver alloy for conductivity)
  • Auxiliary contacts (for control circuits)
  • Arc suppression system (grids or vacuum chambers)
  • Mechanical linkage assembly

4. Key Technical Parameters

ParameterSignificance
Rated operational current (Ie)Determines maximum load capacity
Rated voltage (Ue)Defines operating voltage range
Coil power consumptionAffects control circuit design
Mechanical life (cycles)Indicates durability without maintenance
Short-circuit withstandSafety margin for fault conditions

5. Application Fields

Primary industries include:

  • Industrial automation (motor control centers)
  • Power generation and distribution systems
  • Building HVAC equipment
  • Transportation infrastructure (traction systems)
  • Agricultural machinery (irrigation pumps)

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
Schneider ElectricTeSys D Green Contactors
Siemens3RT12xx series
ABBAF110-30LX vacuum contactor
OmronMY22S DC contactor

7. Selection Guidelines

Key considerations:

  • Load type (resistive/inductive) and inrush current
  • Environmental conditions (temperature, vibration)
  • Control voltage compatibility
  • Mounting orientation and space constraints
  • Certification requirements (IEC 61439, UL 508)
Example: For 400A motor control in a foundry, select a heavy-duty contactor with IP54 rating and class F insulation.

8. Industry Trends

Emerging developments:

  • Integration with IoT-enabled monitoring systems
  • Nano-coating technologies for harsh environments
  • Miniaturization through advanced arc suppression
  • Hybrid designs combining solid-state and electromechanical features
  • Eco-friendly materials reducing rare metal dependency

RFQ BOM Call Skype Email
Top