Microscopes

Image Part Number Description / PDF Quantity Rfq
IF-370050

IF-370050

Industrial Fiber Optics, Inc.

MICROSCOPE PRTBL NON-ILLUM

0

Microscopes

1. Overview

Microscopes are optical instruments that use lenses or combinations of lenses to magnify and resolve fine details of specimens beyond the capability of the human eye. They play a critical role in scientific research, industrial quality control, medical diagnostics, and material analysis. Modern microscopes integrate advanced optics, digital imaging, and automation technologies to enable precise visualization and quantitative analysis at microscopic scales.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Optical MicroscopeUses visible light and lenses for magnification (up to 1500x). Includes brightfield, darkfield, phase contrast, and fluorescence modes.Biological sample observation, histology, metallurgical analysis
Electron MicroscopeUtilizes electron beams for ultra-high resolution (up to 0.1 nm). Includes SEM (Scanning Electron Microscope) and TEM (Transmission Electron Microscope).Nanomaterial characterization, semiconductor defect analysis, virus imaging
Scanning Probe MicroscopeMeasures surface topography at atomic levels using a physical probe. Includes AFM (Atomic Force Microscope) and STM (Scanning Tunneling Microscope).Surface roughness measurement, molecular manipulation
Confocal MicroscopeUses laser scanning and pinhole apertures to eliminate out-of-focus light, enabling 3D imaging.Cell biology, fluorescent labeling, thick tissue imaging

3. Structure and Components

Typical components of an optical microscope include:

  • Optical System: Objective lenses (4x 100x magnification), eyepieces (10x 25x), and light source (LED, halogen, or laser).
  • Mechanical Frame: Stage for sample placement, focus adjustment knobs (coarse/fine), and revolver for lens switching.
  • Digital Imaging System: CMOS/CCD camera, image processing software, and display monitor.
  • Control Interface: Joystick for manual operation, motorized stages for automated scanning, and software for data analysis.

4. Key Technical Specifications

ParameterDescriptionImportance
ResolutionMinimum distance between two distinguishable points (0.2 m for optical microscopes).Determines the clarity of fine details.
Magnification RangeCombined power of objective and eyepiece (e.g., 40x 1000x).Defines observable sample size limits.
Numerical Aperture (NA)Light-gathering ability of the objective lens (e.g., 0.1 1.4).Impacts resolution and depth of field.
Field of View (FOV)Area visible in a single view (e.g., 0.5 2 mm diameter).Affects sample navigation efficiency.
Working DistanceDistance between objective lens and sample (e.g., 0.5 50 mm).Determines compatibility with large/3D samples.

5. Application Fields

Key industries and applications:

  • Life Sciences: Cellular morphology, histopathology, live-cell imaging.
  • Materials Science: Metallography, polymer surface analysis, composite material testing.
  • Semiconductor Industry: Wafer defect detection, circuit inspection (e.g., AOI systems).
  • Clinical Diagnostics: Blood smear analysis, microbiology, cytology.
  • Education: Student microscopes for basic biological research.

Case Study: In semiconductor manufacturing, confocal microscopes are used to inspect photomasks for defects smaller than 100 nm, ensuring chip yield rates exceed 95%.

6. Leading Manufacturers and Representative Products

ManufacturerProduct ExampleKey Specifications
Carl ZeissAxio Imager 2Resolution: 0.12 m, 100W LED illumination, motorized stage
NikonEclipse Ti2Max magnification: 1000x, CFI60 optical system
OlympusBX536-axis motorized control, fluorescence imaging capability
Leica MicrosystemsDM6 BAutomated magnification selection, color camera resolution: 18 MP

7. Selection Guidelines

Key considerations:

  1. Application Requirements: Choose optical microscopes for live samples, electron microscopes for sub-nanometer resolution.
  2. Budget Constraints: Entry-level models cost $5,000 $20,000; electron microscopes range from $100,000 to over $1M.
  3. Automation Needs: Motorized stages and AI-based analysis software are essential for high-throughput production lines.
  4. Sample Characteristics: Transparent samples require phase-contrast or DIC optics; conductive materials need SEM compatibility.
  5. Future Scalability: Modular systems allow upgrades with fluorescence modules or Raman spectroscopy integration.

8. Industry Trends

Future developments include:

  • Super-Resolution Imaging: Techniques like STED and PALM breaking the diffraction limit (resolution <50 nm).
  • AI Integration: Deep learning algorithms for automatic defect classification in industrial inspection.
  • Multi-Modal Systems: Combined optical and X-ray tomography for 3D structural analysis.
  • Miniaturization: Portable microscopes with smartphone connectivity for field diagnostics.
  • Eco-Design: Energy-efficient LED illumination and recyclable polymer components.
RFQ BOM Call Skype Email
Top