Motors - AC, DC

Image Part Number Description / PDF Quantity Rfq
R88M-GP10030L-BOS2

R88M-GP10030L-BOS2

Omron Automation & Safety Services

SERVOMOTOR 3000 RPM 100V

0

R88M-K3K010C-BS2

R88M-K3K010C-BS2

Omron Automation & Safety Services

SERVOMOTOR 1000 RPM 400V

0

R88M-K4K020H

R88M-K4K020H

Omron Automation & Safety Services

SERVOMOTOR 2000 RPM 230V

0

R88G-HPG50A332K0SB

R88G-HPG50A332K0SB

Omron Automation & Safety Services

MOTOR DECLRTR 3ARC-MIN BCKLSH

0

R88M-K2K030T

R88M-K2K030T

Omron Automation & Safety Services

SERVOMOTOR 3000 RPM 230V

0

R88M-K3K030H

R88M-K3K030H

Omron Automation & Safety Services

SERVOMOTOR 3000 RPM 230V

0

R88M-G40030L-S2

R88M-G40030L-S2

Omron Automation & Safety Services

SERVOMOTOR 3000 RPM 100V

0

R88M-K90010T-OS2

R88M-K90010T-OS2

Omron Automation & Safety Services

SERVOMOTOR 1000 RPM 230V

0

R88M-K1K020T-BOS2

R88M-K1K020T-BOS2

Omron Automation & Safety Services

SERVOMOTOR 2000 RPM 230V

0

R88M-K20030H-OS2

R88M-K20030H-OS2

Omron Automation & Safety Services

SERVOMOTOR 3000 RPM 230V

0

R88M-G7K515T-BS2

R88M-G7K515T-BS2

Omron Automation & Safety Services

SERVOMOTOR 1500 RPM 200V

0

R88M-K15K015T-S2

R88M-K15K015T-S2

Omron Automation & Safety Services

SERVOMOTOR 1500 RPM 240V

0

R88M-K5K020F-B

R88M-K5K020F-B

Omron Automation & Safety Services

SERVOMOTOR 2000 RPM 400V

0

R88M-GP20030T

R88M-GP20030T

Omron Automation & Safety Services

SERVOMOTOR 3000 RPM 200V

0

R88M-GP20030T-B

R88M-GP20030T-B

Omron Automation & Safety Services

SERVOMOTOR 3000 RPM 200V

0

R88M-K3K010H-BS2

R88M-K3K010H-BS2

Omron Automation & Safety Services

SERVOMOTOR 1000 RPM 230V

0

R88M-GP20030S-B

R88M-GP20030S-B

Omron Automation & Safety Services

SERVOMOTOR 3000 RPM 100V

0

R88M-G3K020T-BS2

R88M-G3K020T-BS2

Omron Automation & Safety Services

SERVOMOTOR 2000 RPM 200V

0

R88M-G40030L-OS2

R88M-G40030L-OS2

Omron Automation & Safety Services

SERVOMOTOR 3000 RPM 100V

0

R88M-K20030S-BOS2

R88M-K20030S-BOS2

Omron Automation & Safety Services

SERVOMOTOR 3000 RPM 120V

0

Motors - AC, DC

1. Overview

AC and DC motors are electromechanical devices that convert electrical energy into mechanical motion. AC motors operate on alternating current and rely on electromagnetic induction, while DC motors use direct current and commutator-based commutation. These motors form the backbone of modern industrial automation, transportation systems, and consumer electronics, enabling precise control of motion in applications ranging from factory automation to household appliances.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
AC Induction MotorsSelf-starting, rugged construction, variable speed via frequency controlConveyor belts, pumps, HVAC systems
DC Brushed MotorsSimple speed control via voltage adjustment, carbon brushes for commutationPower tools, automotive actuators
Brushless DC MotorsElectronic commutation, high efficiency, low maintenanceDrones, electric vehicles, CNC machines
Servo MotorsPosition control with feedback loops, high torque-to-inertia ratioRobotics, camera gimbals, packaging machines
Stepper MotorsDiscrete angular movements, open-loop position control3D printers, textile machines, medical scanners

3. Structure and Components

Typical motor components include:

  • Stator: Stationary magnetic field component with windings
  • Rotor: Rotating assembly with conductive bars (AC) or armature coils (DC)
  • Bearings: Support shaft rotation with minimal friction
  • Commutator/Brushes: In DC motors, for current direction switching
  • Enclosure: Protects internal components and provides mounting features
  • Shaft: Transmits mechanical power to load

4. Key Technical Specifications

ParameterDescriptionImportance
Power Rating (kW/HP)Maximum continuous mechanical outputDetermines load capacity
RPMNo-load rotational speed at rated voltage/frequencyMatches motor to application speed
Torque (Nm)Rotational force capabilityCrucial for acceleration and load handling
Efficiency (%)Electrical to mechanical energy conversion rateAffects operating costs and heat generation
Ingress Protection (IP)Environmental protection ratingDetermines suitability for harsh environments
Duty CycleOperating time vs. rest periodPrevents overheating in cyclic operations

5. Application Fields

  • Industrial: CNC machining centers, automated guided vehicles
  • Consumer: Washing machines, electric fans, power windows
  • Medical: MRI scanners, infusion pumps, surgical robots
  • Transportation: Electric vehicle propulsion, locomotive traction
  • Renewables: Wind turbine generators, solar tracking systems

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
SiemensSIMOTICS M-1SM1High-efficiency IE4 motor, IP65 protection
ABBACS880 Servo DriveMulti-axis coordination, dynamic response
Maxon MotorEC-i40 BrushlessSlotless design, 40mm diameter
PortescapDisc Magnet MotorsHigh torque-to-inertia ratio
Yaskawa ElectricMP Series Servos24-bit absolute encoder, vibration suppression

7. Selection Guidelines

  1. Calculate required torque and speed using load dynamics
  2. Assess environmental conditions (temperature, humidity, dust)
  3. Choose between AC/DC based on power supply availability
  4. Consider control requirements (position/velocity accuracy)
  5. Evaluate maintenance requirements and lifecycle costs
  6. Verify mounting dimensions and shaft compatibility
  7. Check compliance with industry standards (IEC, NEMA)

8. Industry Trends

Current developments include:

  • Increased adoption of IoT-enabled "smart" motors with condition monitoring
  • Integration with AI-based predictive maintenance systems
  • Development of high-torque density motors for electric vehicles
  • Advancements in wide bandgap semiconductor drives (SiC/GaN)
  • Miniaturization for portable medical and robotics applications
  • Focus on IE5 ultra-premium efficiency standards compliance

Actual Case: In a semiconductor manufacturing plant, replacing standard AC motors with high-precision brushless DC motors in wafer handling systems reduced positioning errors by 60% while decreasing energy consumption by 25% through optimized drive algorithms.

RFQ BOM Call Skype Email
Top