Uninterruptible Power Supply (UPS) Systems

Image Part Number Description / PDF Quantity Rfq
2905909

2905909

Phoenix Contact

1AC/1AC/750 VA UNINTERRUPTIBLE P

1

2906991

2906991

Phoenix Contact

QUINT UPS IQ 24VDC 5A

87

2907074

2907074

Phoenix Contact

QUINT UPS IQ 24VDC 20A

3

2907081

2907081

Phoenix Contact

QUINT UPS IQ 24VDC 40A

11

2868703

2868703

Phoenix Contact

UPS 18.5VDC 1.4AH DIN RAIL

0

2907066

2907066

Phoenix Contact

QUINT UPS IQ 24VDC 10A

10

2907077

2907077

Phoenix Contact

QUINT UPS IQ 24VDC 40A

15

2910119

2910119

Phoenix Contact

DC/DC CONVERTER 24V 120W

4

2907070

2907070

Phoenix Contact

QUINT UPS IQ 24VDC 10A

0

2906994

2906994

Phoenix Contact

QUINT UPS IQ 24VDC 5A

26200

2320212

2320212

Phoenix Contact

UPS 24VDC 5A DIN RAIL

24103

2320267

2320267

Phoenix Contact

QUINT-UPS/ 24DC/ 24DC/10/3.4AH

2524

2905907

2905907

Phoenix Contact

UPS 24VDC 2.5A DIN RAIL

119

2907080

2907080

Phoenix Contact

QUINT UPS IQ 24VDC 40A

1168

2910120

2910120

Phoenix Contact

DC/DC CONVERTER 24V 240W

11

2906993

2906993

Phoenix Contact

QUINT UPS IQ 24VDC 5A

0

2320283

2320283

Phoenix Contact

QUINT UPS IQ 120/230VAC

218

2907078

2907078

Phoenix Contact

QUINT UPS IQ 24VDC 40A

20

Uninterruptible Power Supply (UPS) Systems

1. Overview

An Uninterruptible Power Supply (UPS) is an electrical device that provides emergency power to connected equipment during utility power failures or voltage fluctuations. It ensures continuous operation, protects against data loss, and prevents hardware damage. UPS systems are critical in modern technology environments where power reliability is essential, such as data centers, healthcare facilities, and industrial automation systems.

2. Main Types and Functional Classification

Type Functional Features Application Examples
Offline/Standby UPS Switches to battery backup during outages; minimal protection Home computers, small office equipment
Line-Interactive UPS Regulates voltage without switching to battery; moderate protection Entry-level servers, networking equipment
Online Double-Conversion UPS Provides seamless power with zero transfer time; advanced isolation Data centers, medical imaging systems
Modular UPS Scalable design with hot-swappable components Cloud computing infrastructure, large enterprises
Smart UPS Integrated IoT connectivity for remote monitoring and management Smart buildings, industrial IoT systems

3. Structure and Components

A typical UPS system consists of:

  • Input Circuit Breaker: Controls power intake from utility
  • Rectifier: Converts AC to DC for battery charging
  • Battery Bank: Stores energy for backup power supply
  • Inverter: Converts DC back to AC for connected loads
  • Bypass Circuit: Routes power around internal components during maintenance
  • Control System: Monitors performance and manages power transitions

Advanced models include thermal management systems, harmonic filters, and network interface modules.

4. Key Technical Specifications

Parameter Importance
Power Capacity (kVA/kW) Determines maximum load support
Transfer Time (ms) Critical for sensitive equipment (0ms required for online UPS)
Runtime at Full Load (minutes) Defines emergency operation duration
Efficiency (%) Impacts energy costs and heat generation
Waveform Output Sinusoidal for critical equipment, simulated sine for basic loads
Battery Technology Lead-acid (cost-effective) vs. Lithium-ion (longer lifespan)

5. Application Fields

  • IT Infrastructure: Servers, storage arrays, network switches
  • Healthcare: MRI machines, patient monitoring systems
  • Manufacturing: PLC controllers, assembly line automation
  • Telecommunications: Base stations, fiber optic networks
  • Financial Sector: ATMs, trading platforms, data vaults

6. Leading Manufacturers and Products

Manufacturer Representative Product
Schneider Electric Galaxy VX (Modular UPS, 500kW scalable)
APC by Schneider Symmetra MW (3-phase modular system for data centers)
Eaton 93PM Series (99% efficient double-conversion UPS)
Vertiv NetSure DC Power System (Telco-specific UPS)
UPS5000-E (Lithium-ion battery integrated system)

7. Selection Recommendations

Key considerations:

  • Calculate total load requirements with 20% headroom
  • Assess required runtime (e.g., 10 minutes for graceful shutdown vs. hours for critical systems)
  • Environmental factors: operating temperature, humidity, and physical space
  • Management features: SNMP support, cloud monitoring, predictive maintenance
  • Total Cost of Ownership (TCO) including battery replacement cycles

Case Study: A 500kW data center selected modular online UPS systems with lithium-ion batteries, achieving 99.999% uptime and 15% energy savings through eco-mode operation.

8. Industry Trends

  • Modular Architecture: Growing adoption of scalable systems for flexible capacity planning
  • Green Energy Integration: Hybrid UPS systems combining solar and battery storage
  • AI-Driven Management: Predictive analytics for battery health and failure prevention
  • Edge Computing Support: Compact UPS solutions for distributed IT infrastructure
  • Standardization: Adoption of IEC 62040 and IEEE 1159 compliance as global benchmarks
RFQ BOM Call Skype Email