Uninterruptible Power Supply (UPS) Systems

Image Part Number Description / PDF Quantity Rfq
SVX60KL

SVX60KL

Tripp Lite

SMARTONLINE SVX SERIES 60KVA MOD

0

SU1000RTXLCD2UN

SU1000RTXLCD2UN

Tripp Lite

120V 1000VA 900W DOUBLE-CONVERSI

27

SMART1000RM2UL

SMART1000RM2UL

Tripp Lite

SMARTPRO UPS, LITHIUM BATTERY BA

9

SV100KL

SV100KL

Tripp Lite

100KVA SMART ONLINE 3-PHASE UPS

27

SMX1500XLRT2UN

SMX1500XLRT2UN

Tripp Lite

SMARTPRO 230V 1500VA 1350W LINE-

24

SU2000RTXLCD2U

SU2000RTXLCD2U

Tripp Lite

120V 2000VA 1.8KW DOUBLE-CONVERS

53

SU10000RT3UTAA

SU10000RT3UTAA

Tripp Lite

SMARTONLINE 208/240V 10KVA ON-LI

1

SV40KM2P0B

SV40KM2P0B

Tripp Lite

SMARTONLINE SV SERIES 40KVA MEDI

27

SUINT1000XLCD

SUINT1000XLCD

Tripp Lite

SMARTONLINE 230V 1KVA 900W ON-LI

17

SU6000RT4UTFTAA

SU6000RT4UTFTAA

Tripp Lite

SMARTONLINE 120/208/240V 6KVA ON

0

SU1500RTXLCDTAA

SU1500RTXLCDTAA

Tripp Lite

SMARTONLINE 120V 1.5KVA TAA-COMP

21

SV80KM4P0B

SV80KM4P0B

Tripp Lite

SMARTONLINE SV SERIES 80KVA MEDI

27

SV40KM2P2B

SV40KM2P2B

Tripp Lite

40KVA SMART ONLINE 3-PHASE UPS M

27

SV140KL8P

SV140KL8P

Tripp Lite

140KVA SMART ONLINE 3PHASE UPS M

27

SMART750TSU

SMART750TSU

Tripp Lite

750VA 600W LINE-INTERACTIVE UPS

19

SU3000RTXLCDTAA

SU3000RTXLCDTAA

Tripp Lite

SMARTONLINE 120V 3KVA TAA-COMPLI

29

SU2200RTXLCDTAA

SU2200RTXLCDTAA

Tripp Lite

SMARTONLINE 120V 2.2KVA TAA-COMP

0

S3M120KX

S3M120KX

Tripp Lite

SMARTONLINE S3MX SERIES 3-PHASE

0

SU6000XFMR2U

SU6000XFMR2U

Tripp Lite

STEPDOWN ISOLATION TRANSFORMER

258

SU5000RT4UHVTAA

SU5000RT4UHVTAA

Tripp Lite

SMARTONLINE 208/240V 5KVA ON-LIN

8

Uninterruptible Power Supply (UPS) Systems

1. Overview

An Uninterruptible Power Supply (UPS) is an electrical device that provides emergency power to connected equipment during utility power failures or voltage fluctuations. It ensures continuous operation, protects against data loss, and prevents hardware damage. UPS systems are critical in modern technology environments where power reliability is essential, such as data centers, healthcare facilities, and industrial automation systems.

2. Main Types and Functional Classification

Type Functional Features Application Examples
Offline/Standby UPS Switches to battery backup during outages; minimal protection Home computers, small office equipment
Line-Interactive UPS Regulates voltage without switching to battery; moderate protection Entry-level servers, networking equipment
Online Double-Conversion UPS Provides seamless power with zero transfer time; advanced isolation Data centers, medical imaging systems
Modular UPS Scalable design with hot-swappable components Cloud computing infrastructure, large enterprises
Smart UPS Integrated IoT connectivity for remote monitoring and management Smart buildings, industrial IoT systems

3. Structure and Components

A typical UPS system consists of:

  • Input Circuit Breaker: Controls power intake from utility
  • Rectifier: Converts AC to DC for battery charging
  • Battery Bank: Stores energy for backup power supply
  • Inverter: Converts DC back to AC for connected loads
  • Bypass Circuit: Routes power around internal components during maintenance
  • Control System: Monitors performance and manages power transitions

Advanced models include thermal management systems, harmonic filters, and network interface modules.

4. Key Technical Specifications

Parameter Importance
Power Capacity (kVA/kW) Determines maximum load support
Transfer Time (ms) Critical for sensitive equipment (0ms required for online UPS)
Runtime at Full Load (minutes) Defines emergency operation duration
Efficiency (%) Impacts energy costs and heat generation
Waveform Output Sinusoidal for critical equipment, simulated sine for basic loads
Battery Technology Lead-acid (cost-effective) vs. Lithium-ion (longer lifespan)

5. Application Fields

  • IT Infrastructure: Servers, storage arrays, network switches
  • Healthcare: MRI machines, patient monitoring systems
  • Manufacturing: PLC controllers, assembly line automation
  • Telecommunications: Base stations, fiber optic networks
  • Financial Sector: ATMs, trading platforms, data vaults

6. Leading Manufacturers and Products

Manufacturer Representative Product
Schneider Electric Galaxy VX (Modular UPS, 500kW scalable)
APC by Schneider Symmetra MW (3-phase modular system for data centers)
Eaton 93PM Series (99% efficient double-conversion UPS)
Vertiv NetSure DC Power System (Telco-specific UPS)
UPS5000-E (Lithium-ion battery integrated system)

7. Selection Recommendations

Key considerations:

  • Calculate total load requirements with 20% headroom
  • Assess required runtime (e.g., 10 minutes for graceful shutdown vs. hours for critical systems)
  • Environmental factors: operating temperature, humidity, and physical space
  • Management features: SNMP support, cloud monitoring, predictive maintenance
  • Total Cost of Ownership (TCO) including battery replacement cycles

Case Study: A 500kW data center selected modular online UPS systems with lithium-ion batteries, achieving 99.999% uptime and 15% energy savings through eco-mode operation.

8. Industry Trends

  • Modular Architecture: Growing adoption of scalable systems for flexible capacity planning
  • Green Energy Integration: Hybrid UPS systems combining solar and battery storage
  • AI-Driven Management: Predictive analytics for battery health and failure prevention
  • Edge Computing Support: Compact UPS solutions for distributed IT infrastructure
  • Standardization: Adoption of IEC 62040 and IEEE 1159 compliance as global benchmarks
RFQ BOM Call Skype Email
Top