Power Distribution, Surge Protectors

Image Part Number Description / PDF Quantity Rfq
PDU3EVS6H50

PDU3EVS6H50

Tripp Lite

14.5KW 3-PHASE PDU, VERTICAL, SW

9

PDU3XEVSR6G32A

PDU3XEVSR6G32A

Tripp Lite

22.2KW 3-PHASE SWITCHED PDU - 12

21

PDU3EVSR6L1530

PDU3EVSR6L1530

Tripp Lite

3-PHASE PDU SWITCHED 10KW 200/20

3

PDUMV30HV2

PDUMV30HV2

Tripp Lite

POWER OUTLET STRIPS

70

PDU3EVSR6L2120

PDU3EVSR6L2120

Tripp Lite

6.7KW 3-PHASE SWITCHED PDU - LX

10

TLP1G

TLP1G

Tripp Lite

1-OUTLET SURGE PROTECTOR - GERMA

50182

PDU3EVSR6G60

PDU3EVSR6G60

Tripp Lite

3-PHASE PDU SWITCHED 10KW 200/20

9

DB25-PAR

DB25-PAR

Tripp Lite

SERIAL PROT SURGE PROT PARALLEL

0

PDU3VN3G60

PDU3VN3G60

Tripp Lite

PDU 3-PHASE MONITORD 208V 12.6KW

0

TLP66NETAA

TLP66NETAA

Tripp Lite

SURGE PROTECT RJ45 6 OUTLET 6FT

0

PDUMNV30HV

PDUMNV30HV

Tripp Lite

PDU MONITORED 208V/240V 30A C13

0

PDU3VSR3L2130

PDU3VSR3L2130

Tripp Lite

PDU 3-PHASE SWITCHED 208V 8.6KW

0

PDUMH20NET2

PDUMH20NET2

Tripp Lite

PDU SWITCHED 5-15/20R 8 OUTLET

0

PDU3VN3H50

PDU3VN3H50

Tripp Lite

PDU 3-PHASE MONITORD 208V 12.6KW

0

PDUMVR30NET

PDUMVR30NET

Tripp Lite

PDU SWITCHED 5-15/20R 24 OUTLET

0

PDUMNV30

PDUMNV30

Tripp Lite

PDU MONITORED 5-15/20R 24 OUTLET

0

PDUMNV20

PDUMNV20

Tripp Lite

PDU MONITORED 5-15/20R 24 OUTLET

0

PDU3VN3L1530

PDU3VN3L1530

Tripp Lite

PDU 3-PHASE MONITORED 208V 8.6KW

0

AV810

AV810

Tripp Lite

HOME THEATER PREMIUM SURGE 8 OUT

0

TLP82D

TLP82D

Tripp Lite

INTL SURGE PROT 8 SCHUKO OUTLET

0

Power Distribution, Surge Protectors

1. Overview

Power distribution and surge protection systems are critical components in modern electrical infrastructure. These systems ensure reliable power delivery, protect equipment from voltage spikes, and maintain operational continuity. Line protection devices safeguard against transient voltages, while power distribution units (PDUs) manage electricity allocation across networks. Surge protectors (SPDs) mitigate damage from lightning strikes or power surges. Together, these technologies form the backbone of stable power management in residential, commercial, and industrial applications.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Surge Protective Devices (SPDs)Divert transient surges to ground, maintain normal operationData centers, telecommunication systems
Isolation TransformersGalvanically isolate circuits, suppress electrical noiseHospitals, laboratory equipment
Uninterruptible Power Supplies (UPS)Provide backup power during outages, regulate voltageServer rooms, critical manufacturing systems
Power Distribution Units (PDUs)Monitor and distribute power to multiple outletsIT racks, data cabinets

3. Structure and Components

Typical surge protectors contain metal oxide varistors (MOVs), gas discharge tubes (GDTs), and thermal disconnects. PDUs feature hardened steel enclosures with multiple output sockets, integrated circuit breakers, and optional monitoring modules. UPS systems combine battery arrays, inverters, and automatic transfer switches. Advanced models incorporate IoT-enabled sensors for real-time voltage/current monitoring and predictive maintenance capabilities.

4. Key Technical Specifications

ParameterDescriptionImportance
Clamping VoltageMaximum voltage allowed during surgeDetermines protection level
Response TimeTime to activate protection (ns)Faster = better equipment safety
Energy Rating (Joules)Surge energy absorption capacityHigher = longer device lifespan
Network ManagementSNMP/Modbus connectivity supportEssential for system integration

5. Application Areas

  • IT Infrastructure: Server racks, network switches
  • Industrial: PLC systems, CNC machines
  • Healthcare: MRI/CT scanners, life-support systems
  • Renewables: Solar inverters, wind turbine controllers

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
APC by Schneider ElectricSmart-UPS On-LineDouble-conversion topology, 0ms transfer time
Eaton5P Series SPDHybrid technology, 400kA surge capacity
Phoenix ContactPT-IQ Power MonitorIoT-enabled energy analytics
RaritanPX Intelligent PDUPer-outlet metering, 15-year warranty

7. Selection Recommendations

Key considerations include:

  • Voltage compatibility with existing infrastructure
  • Surge current capacity (min. 20kA for critical systems)
  • Redundancy requirements for mission-critical loads
  • Environmental factors (temperature, humidity)
Case Study: Hospital CT scanner protection using Eaton's BDX-UPS system achieved 99.999% uptime through dual-battery redundancy and real-time diagnostics.

8. Industry Trends

Emerging developments include:

  • AI-powered predictive maintenance algorithms
  • Modular hybrid systems combining UPS + SPD functions
  • Integration with smart grid technologies
  • Increased adoption of wide bandgap semiconductors (SiC, GaN)
Market growth projections show 8.7% CAGR through 2030, driven by data center expansion and renewable energy integration requirements.

RFQ BOM Call Skype Email