Power Distribution, Surge Protectors

Image Part Number Description / PDF Quantity Rfq
DSUT1CSU

DSUT1CSU

Tripp Lite

SURGE SUPPR NETWORK W/GROUND

7300

PDU3EVNR6L2130

PDU3EVNR6L2130

Tripp Lite

10KW 3-PHASE MONITORED PER-OUTLE

9

SUPER7TEL15

SUPER7TEL15

Tripp Lite

SURGE SUPPR 7OUT 15'CORD W/RJ11

23700

DNET1

DNET1

Tripp Lite

SURGE SUPPRESSOR ETHERNET RJ45

2000

TLP707TEL

TLP707TEL

Tripp Lite

SURGE SUPPRESSOR 15A 7OUT 7'CORD

18500

TLM825GF

TLM825GF

Tripp Lite

POWER STRIP 8OUT 25'CORD

5990

STRIKER

STRIKER

Tripp Lite

SURGE SUPPRESSR 120V 7OUT 6'CORD

617500

TLP604TEL

TLP604TEL

Tripp Lite

SURGE SUP 15A 6OUT 4'CORD W/RJ11

93920

TLP1210SATG

TLP1210SATG

Tripp Lite

POWER STRIP 12OUT 10'CORD

5342

HT706TSAT

HT706TSAT

Tripp Lite

SURGE SUPPRESSOR 7OUT W/2COAX

0

PDUH20-ISO6

PDUH20-ISO6

Tripp Lite

1.92KW 120V SINGLE-PHASE BASIC P

156

DRS-1215

DRS-1215

Tripp Lite

SURGE SUPPRSSR 15A 14OUT RACKMNT

815262

ISOBAR8 ULTRA

ISOBAR8 ULTRA

Tripp Lite

SURGE SUPPR 8OUT 12'CORD W/LED

561140

PS1916D1U

PS1916D1U

Tripp Lite

RACK MOUNT AC CHARGER POWER STRI

9312

PDU3XVSR10G16

PDU3XVSR10G16

Tripp Lite

PDU INTL 3-PHASE MONITORED 230V

0

HT10DBS

HT10DBS

Tripp Lite

SURGE SUPPRESS 12A 10OUT 8'CORD

562

PS3612-20HW

PS3612-20HW

Tripp Lite

POWER STRIP 36" 12OUT NO CORD

12120

TLP808TEL

TLP808TEL

Tripp Lite

SURGE SUP 15A 8OUT 8'CORD W/RJ11

0

PS4816

PS4816

Tripp Lite

POWER STRIP 48"X16 OUT 15'CORD

101560

PDU3XVSR6G20

PDU3XVSR6G20

Tripp Lite

PDU INTL 3-PHASE SWITCHED

1

Power Distribution, Surge Protectors

1. Overview

Power distribution and surge protection systems are critical components in modern electrical infrastructure. These systems ensure reliable power delivery, protect equipment from voltage spikes, and maintain operational continuity. Line protection devices safeguard against transient voltages, while power distribution units (PDUs) manage electricity allocation across networks. Surge protectors (SPDs) mitigate damage from lightning strikes or power surges. Together, these technologies form the backbone of stable power management in residential, commercial, and industrial applications.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Surge Protective Devices (SPDs)Divert transient surges to ground, maintain normal operationData centers, telecommunication systems
Isolation TransformersGalvanically isolate circuits, suppress electrical noiseHospitals, laboratory equipment
Uninterruptible Power Supplies (UPS)Provide backup power during outages, regulate voltageServer rooms, critical manufacturing systems
Power Distribution Units (PDUs)Monitor and distribute power to multiple outletsIT racks, data cabinets

3. Structure and Components

Typical surge protectors contain metal oxide varistors (MOVs), gas discharge tubes (GDTs), and thermal disconnects. PDUs feature hardened steel enclosures with multiple output sockets, integrated circuit breakers, and optional monitoring modules. UPS systems combine battery arrays, inverters, and automatic transfer switches. Advanced models incorporate IoT-enabled sensors for real-time voltage/current monitoring and predictive maintenance capabilities.

4. Key Technical Specifications

ParameterDescriptionImportance
Clamping VoltageMaximum voltage allowed during surgeDetermines protection level
Response TimeTime to activate protection (ns)Faster = better equipment safety
Energy Rating (Joules)Surge energy absorption capacityHigher = longer device lifespan
Network ManagementSNMP/Modbus connectivity supportEssential for system integration

5. Application Areas

  • IT Infrastructure: Server racks, network switches
  • Industrial: PLC systems, CNC machines
  • Healthcare: MRI/CT scanners, life-support systems
  • Renewables: Solar inverters, wind turbine controllers

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
APC by Schneider ElectricSmart-UPS On-LineDouble-conversion topology, 0ms transfer time
Eaton5P Series SPDHybrid technology, 400kA surge capacity
Phoenix ContactPT-IQ Power MonitorIoT-enabled energy analytics
RaritanPX Intelligent PDUPer-outlet metering, 15-year warranty

7. Selection Recommendations

Key considerations include:

  • Voltage compatibility with existing infrastructure
  • Surge current capacity (min. 20kA for critical systems)
  • Redundancy requirements for mission-critical loads
  • Environmental factors (temperature, humidity)
Case Study: Hospital CT scanner protection using Eaton's BDX-UPS system achieved 99.999% uptime through dual-battery redundancy and real-time diagnostics.

8. Industry Trends

Emerging developments include:

  • AI-powered predictive maintenance algorithms
  • Modular hybrid systems combining UPS + SPD functions
  • Integration with smart grid technologies
  • Increased adoption of wide bandgap semiconductors (SiC, GaN)
Market growth projections show 8.7% CAGR through 2030, driven by data center expansion and renewable energy integration requirements.