Power Distribution, Surge Protectors

Image Part Number Description / PDF Quantity Rfq
2859987

2859987

Phoenix Contact

SURGE PROTECTION FILTER 230VAC

414

1586T10D1

1586T10D1

Hammond Manufacturing

POWER STRIP 60" 15A 10OUT 15'

0

P36E12M

P36E12M

Panduit Corporation

MS PDU, 28AMP, (30)C13, (6)C19,

1

1583H6C1

1583H6C1

Hammond Manufacturing

POWER STRIP 19"15A 6OUT 6'CRD GR

0

1587T12D1

1587T12D1

Hammond Manufacturing

POWER STRIP 70" 15A 12OUT 15'

0

1584T7B1

1584T7B1

Hammond Manufacturing

POWER STRIP 17" 15A 7OUT 15'

0

1586T12C1

1586T12C1

Hammond Manufacturing

POWER STRIP 60" 15A 12OUT 6'C

0

TLP806TEL

TLP806TEL

Tripp Lite

SURGE SUPPRESSOR 8 OUT 6FT

1012

PDU1220T6

PDU1220T6

Tripp Lite

SINGLE-PHASE BASIC PDU - 13 NEMA

156

P36B26M

P36B26M

Panduit Corporation

BASIC PDU, 30AMP, (30)C13(6)C19,

251

15852T8A1

15852T8A1

Hammond Manufacturing

POWER STRIP 24" 15A 8OUT 6'CR

0

1583H12A1BKX

1583H12A1BKX

Hammond Manufacturing

POWER STRIP 19"15A 12OUT 6' CORD

45

1583T6B1BKRA

1583T6B1BKRA

Hammond Manufacturing

POWER STRIP 19" 15A 6OUT 15'CORD

0

1587T10A1

1587T10A1

Hammond Manufacturing

POWER STRIP 70" 15A 10OUT 6'C

3

1583H6A1SBK

1583H6A1SBK

Hammond Manufacturing

SURGE SUPPRESSR 6OUT 6' CORD

2

TLP76MSG

TLP76MSG

Tripp Lite

SURGE SUPPRESSOR 7 OUT

49546

2800813

2800813

Phoenix Contact

SURGE PROTECTION DEVICE

3

1585T16C1

1585T16C1

Hammond Manufacturing

POWER STRIP 48" 15A 16OUT 6'C

0

15852T8D1

15852T8D1

Hammond Manufacturing

POWER STRIP 24" 15A 8OUT 15'C

0

DSUT1CSU

DSUT1CSU

Tripp Lite

SURGE SUPPR NETWORK W/GROUND

7300

Power Distribution, Surge Protectors

1. Overview

Power distribution and surge protection systems are critical components in modern electrical infrastructure. These systems ensure reliable power delivery, protect equipment from voltage spikes, and maintain operational continuity. Line protection devices safeguard against transient voltages, while power distribution units (PDUs) manage electricity allocation across networks. Surge protectors (SPDs) mitigate damage from lightning strikes or power surges. Together, these technologies form the backbone of stable power management in residential, commercial, and industrial applications.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Surge Protective Devices (SPDs)Divert transient surges to ground, maintain normal operationData centers, telecommunication systems
Isolation TransformersGalvanically isolate circuits, suppress electrical noiseHospitals, laboratory equipment
Uninterruptible Power Supplies (UPS)Provide backup power during outages, regulate voltageServer rooms, critical manufacturing systems
Power Distribution Units (PDUs)Monitor and distribute power to multiple outletsIT racks, data cabinets

3. Structure and Components

Typical surge protectors contain metal oxide varistors (MOVs), gas discharge tubes (GDTs), and thermal disconnects. PDUs feature hardened steel enclosures with multiple output sockets, integrated circuit breakers, and optional monitoring modules. UPS systems combine battery arrays, inverters, and automatic transfer switches. Advanced models incorporate IoT-enabled sensors for real-time voltage/current monitoring and predictive maintenance capabilities.

4. Key Technical Specifications

ParameterDescriptionImportance
Clamping VoltageMaximum voltage allowed during surgeDetermines protection level
Response TimeTime to activate protection (ns)Faster = better equipment safety
Energy Rating (Joules)Surge energy absorption capacityHigher = longer device lifespan
Network ManagementSNMP/Modbus connectivity supportEssential for system integration

5. Application Areas

  • IT Infrastructure: Server racks, network switches
  • Industrial: PLC systems, CNC machines
  • Healthcare: MRI/CT scanners, life-support systems
  • Renewables: Solar inverters, wind turbine controllers

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
APC by Schneider ElectricSmart-UPS On-LineDouble-conversion topology, 0ms transfer time
Eaton5P Series SPDHybrid technology, 400kA surge capacity
Phoenix ContactPT-IQ Power MonitorIoT-enabled energy analytics
RaritanPX Intelligent PDUPer-outlet metering, 15-year warranty

7. Selection Recommendations

Key considerations include:

  • Voltage compatibility with existing infrastructure
  • Surge current capacity (min. 20kA for critical systems)
  • Redundancy requirements for mission-critical loads
  • Environmental factors (temperature, humidity)
Case Study: Hospital CT scanner protection using Eaton's BDX-UPS system achieved 99.999% uptime through dual-battery redundancy and real-time diagnostics.

8. Industry Trends

Emerging developments include:

  • AI-powered predictive maintenance algorithms
  • Modular hybrid systems combining UPS + SPD functions
  • Integration with smart grid technologies
  • Increased adoption of wide bandgap semiconductors (SiC, GaN)
Market growth projections show 8.7% CAGR through 2030, driven by data center expansion and renewable energy integration requirements.

RFQ BOM Call Skype Email
Top