Power Distribution, Surge Protectors

Image Part Number Description / PDF Quantity Rfq
1530-1-W

1530-1-W

J.W. Miller / Bourns

POE ETHERNET SURGE PROTECTOR

0

TMC-6

TMC-6

Tripp Lite

SURGE SUPPR 6OUT 6'CORD

11130

TLP810NET

TLP810NET

Tripp Lite

SURGE SUP 8OUT RJ11,COAX,ETHRNET

14250

1587T19B1

1587T19B1

Hammond Manufacturing

POWER STRIP 70" 15A 19OUT 15'

0

P36G19M

P36G19M

Panduit Corporation

MSPO PDU, 24AMP, (30)C13, (6)C19

1

1589H18G1

1589H18G1

Hammond Manufacturing

POWER STRIP 18" 20A 6OUT 15'C

53

8924490000

8924490000

Weidmuller

SURGE PROTECTION

5

2910333

2910333

Phoenix Contact

SURGE PROTECTION PLUG TYPE 2

10

2818122

2818122

Phoenix Contact

SURGETRAB PIPE W/INTEGRATED PCB

324

1589H36C1

1589H36C1

Hammond Manufacturing

POWER STRIP 36" 20A 6OUT 6'CR

0

1589T77G1

1589T77G1

Hammond Manufacturing

POWER STRIP 77" 20A 12OUT 15'

0

PDUV15

PDUV15

Tripp Lite

PDU BASIC 15A 5-15R 14 OUTLET

8

1583H12B1BKX

1583H12B1BKX

Hammond Manufacturing

POWER STRIP 19"15A 12OUT 15' CRD

16

PDUMV20HV

PDUMV20HV

Tripp Lite

PDU METERED 208V-240V 20A 6 C19

6

1587T11D1

1587T11D1

Hammond Manufacturing

POWER STRIP 70" 15A 11OUT 15'

0

PDU3EVNR6H50A

PDU3EVNR6H50A

Tripp Lite

14.4KW 3-PHASE MONITORED PER-OUT

6

1587H11B1

1587H11B1

Hammond Manufacturing

POWER STRIP 70" 15A 11OUT 15'

0

1584T5D1

1584T5D1

Hammond Manufacturing

POWER STRIP 13" 15A 5OUT 15'C

0

1584H4B1RA

1584H4B1RA

Hammond Manufacturing

POWER STRIP 14" 15A 4OUT 15' CRD

0

2818850

2818850

Phoenix Contact

CONN ATTACH PLUG FML-FML N

1964

Power Distribution, Surge Protectors

1. Overview

Power distribution and surge protection systems are critical components in modern electrical infrastructure. These systems ensure reliable power delivery, protect equipment from voltage spikes, and maintain operational continuity. Line protection devices safeguard against transient voltages, while power distribution units (PDUs) manage electricity allocation across networks. Surge protectors (SPDs) mitigate damage from lightning strikes or power surges. Together, these technologies form the backbone of stable power management in residential, commercial, and industrial applications.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Surge Protective Devices (SPDs)Divert transient surges to ground, maintain normal operationData centers, telecommunication systems
Isolation TransformersGalvanically isolate circuits, suppress electrical noiseHospitals, laboratory equipment
Uninterruptible Power Supplies (UPS)Provide backup power during outages, regulate voltageServer rooms, critical manufacturing systems
Power Distribution Units (PDUs)Monitor and distribute power to multiple outletsIT racks, data cabinets

3. Structure and Components

Typical surge protectors contain metal oxide varistors (MOVs), gas discharge tubes (GDTs), and thermal disconnects. PDUs feature hardened steel enclosures with multiple output sockets, integrated circuit breakers, and optional monitoring modules. UPS systems combine battery arrays, inverters, and automatic transfer switches. Advanced models incorporate IoT-enabled sensors for real-time voltage/current monitoring and predictive maintenance capabilities.

4. Key Technical Specifications

ParameterDescriptionImportance
Clamping VoltageMaximum voltage allowed during surgeDetermines protection level
Response TimeTime to activate protection (ns)Faster = better equipment safety
Energy Rating (Joules)Surge energy absorption capacityHigher = longer device lifespan
Network ManagementSNMP/Modbus connectivity supportEssential for system integration

5. Application Areas

  • IT Infrastructure: Server racks, network switches
  • Industrial: PLC systems, CNC machines
  • Healthcare: MRI/CT scanners, life-support systems
  • Renewables: Solar inverters, wind turbine controllers

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
APC by Schneider ElectricSmart-UPS On-LineDouble-conversion topology, 0ms transfer time
Eaton5P Series SPDHybrid technology, 400kA surge capacity
Phoenix ContactPT-IQ Power MonitorIoT-enabled energy analytics
RaritanPX Intelligent PDUPer-outlet metering, 15-year warranty

7. Selection Recommendations

Key considerations include:

  • Voltage compatibility with existing infrastructure
  • Surge current capacity (min. 20kA for critical systems)
  • Redundancy requirements for mission-critical loads
  • Environmental factors (temperature, humidity)
Case Study: Hospital CT scanner protection using Eaton's BDX-UPS system achieved 99.999% uptime through dual-battery redundancy and real-time diagnostics.

8. Industry Trends

Emerging developments include:

  • AI-powered predictive maintenance algorithms
  • Modular hybrid systems combining UPS + SPD functions
  • Integration with smart grid technologies
  • Increased adoption of wide bandgap semiconductors (SiC, GaN)
Market growth projections show 8.7% CAGR through 2030, driven by data center expansion and renewable energy integration requirements.

RFQ BOM Call Skype Email
Top