Accessories

Image Part Number Description / PDF Quantity Rfq
2905497

2905497

Phoenix Contact

PT-IQ-5-EX-BE-UT

0

2800246

2800246

Phoenix Contact

VAL-MS/2+0-BE/FM/S2

0

S5KC-EBC-CBL-1M

S5KC-EBC-CBL-1M

SolaHD

EBC CABLE 1 METER

0

WEXT2H

WEXT2H

Tripp Lite

2-YEAR EXTENDED WARRANTY - FOR S

0

BP192V12RT3UTAA

BP192V12RT3UTAA

Tripp Lite

192V EXTERNAL BATTERY PACK FOR S

42

07P.24

07P.24

Finder Relays, Inc.

4 WAY JUMPER 7P SERIES

0

S4K240BATC

S4K240BATC

SolaHD

S4KC 6K EXT BATT CAB 240V

0

W09-EW1-247-1B

W09-EW1-247-1B

Tripp Lite

COMMISSIONING FOR SV OR SVX 3-PH

0

S5KC-RACK-KIT

S5KC-RACK-KIT

SolaHD

RACKMOUNT KIT

0

MLLKC

MLLKC

SolaHD

MULTILINK LICENSE KIT-10 COMP.

0

EBP240V3501NB

EBP240V3501NB

Tripp Lite

UPS BATTERY PACK FOR SV-SERIES 3

0

2905364

2905364

Phoenix Contact

PT-IQ-PTB-BE-UT

0

SDU24DB9

SDU24DB9

SolaHD

RELAY CONTACTS TO DB9 SDU24

0

63T30-BRD-KIT

63T30-BRD-KIT

SolaHD

3PH REG 30KVA BOARD & REPAIR KIT

0

SNMPCARD PC

SNMPCARD PC

SolaHD

SNMP WEB CARD S3K

0

BP192V787C-1PH

BP192V787C-1PH

Tripp Lite

EXTERNAL 192V TOWER BATTERY PACK

0

RMD11AA01

RMD11AA01

Sanyo Denki SanUPS Products

D11A RACK RAIL (500MM-850MM)

0

W11-DM-55

W11-DM-55

Tripp Lite

BASIC ON-SITE INSTALLATION OF DI

0

WEXT2U

WEXT2U

Tripp Lite

2-YEAR EXTENDED WARRANTY - FOR S

0

W02-BW2-1BD

W02-BW2-1BD

Tripp Lite

208V UPS START-UP SERVICE, REGUL

0

Accessories

1. Overview

Line Protection, Distribution, and Backups Accessories refer to a category of electrical equipment designed to safeguard power systems, manage energy distribution, and ensure continuous operation during power disruptions. These components play a critical role in modern infrastructure by preventing equipment damage from voltage fluctuations, optimizing power allocation, and maintaining operational continuity in critical systems.

2. Major Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Power Protection DevicesSurge suppression, voltage stabilization, transient filteringIT server rooms, medical imaging equipment
Distribution EquipmentLoad balancing, circuit isolation, real-time monitoringIndustrial control panels, commercial buildings
Backup SystemsUninterruptible Power Supply (UPS), battery management, automatic transfer switchesData centers, emergency lighting systems
Monitoring AccessoriesPower quality analysis, remote diagnostics, energy consumption trackingSmart grid infrastructure, telecom cabinets

3. Structure & Composition

Typical components include: - Outer housing (flame-retardant polymer/metal alloy) - Circuit breaker modules with thermal-magnetic protection - Transformer cores with electromagnetic shielding - Battery compartments (sealed lead-acid/lithium-ion) - Digital signal processors (DSP) for real-time control - Communication interfaces (RS485, Modbus, SNMP)

4. Key Technical Specifications

ParameterImportance
Rated Voltage (120-480VAC)Determines operational compatibility with power systems
Short Circuit Current Rating (SCCR)Indicates fault current withstand capability
Transfer Time (0-15ms)Measures continuity during power transitions
Energy Efficiency (>95%)Impacts operational cost and thermal management
IP Protection Rating (IP20-IP54)Defines environmental durability

5. Application Fields

  • Telecommunications (4G/5G base stations)
  • Healthcare (MRI scanners, life-support systems)
  • Manufacturing (CNC machine protection)
  • Financial Services (ATM power conditioning)
  • Renewable Energy (Solar inverter integration)

6. Leading Manufacturers & Products

ManufacturerRepresentative Product
Schneider ElectricGalaxy VX UPS system
Eaton Corporation93PM Power Quality Cabinet
APC by SchneiderSmart-UPS On-Line
Phoenix ContactPT 3S UPS modules
SiemensSIRIUS 3RV2 Circuit Breakers

7. Selection Recommendations

Key considerations: - Load requirements (active/reactive power matching) - Environmental conditions (temperature/humidity range) - Compliance standards (UL 1449, IEC 62040-1) - Scalability (modular expansion options) - Maintenance accessibility (hot-swappable components)

Case Study: A data center selected a 2N redundant UPS configuration with lithium-ion batteries, achieving 99.999% uptime while reducing cooling costs by 30% compared to traditional systems.

8. Industry Trends

Future developments include: - AI-powered predictive maintenance systems - Integration with IoT-enabled smart grids - Adoption of wide-bandgap semiconductors (SiC/GaN) - Modular hybrid systems combining protection/distribution/backups - Increased focus on cybersecurity for networked power devices

RFQ BOM Call Skype Email
Top