PMIC - Energy Metering

Image Part Number Description / PDF Quantity Rfq
ADE7753ARSRL

ADE7753ARSRL

Analog Devices, Inc.

SINGLE-PHASE ENERGY MEASUREMENT

1500

ADE7566ASTZF16

ADE7566ASTZF16

Analog Devices, Inc.

SINGLE-PHASE ENERGY MEASUREMENT

2423

LTC2946IMS#TRPBF

LTC2946IMS#TRPBF

Analog Devices, Inc.

IC ENERGY MONITOR I2C 16MSOP

0

AD7751AN

AD7751AN

Analog Devices, Inc.

ENERGY METERING IC

2608

ADE7762ARWZ-RL

ADE7762ARWZ-RL

Analog Devices, Inc.

IC ENERGY METERING 3PHASE 28SOIC

0

ADE7763ARSZRL

ADE7763ARSZRL

Analog Devices, Inc.

POWER SUPPLY SUPPORT CIRCUIT, AD

0

ADE5166ASTZF62

ADE5166ASTZF62

Analog Devices, Inc.

IC METER/8052/RTC/LCD DRV 64LQFP

0

ADE5569ASTZF62

ADE5569ASTZF62

Analog Devices, Inc.

SINGLE-PHASE ENERGY MEASUREMENT

4730

ADE7566ASTZF8

ADE7566ASTZF8

Analog Devices, Inc.

SINGLE-PHASE ENERGY MEASUREMENT

6016

ADE7878ACPZ

ADE7878ACPZ

Analog Devices, Inc.

IC ENERGY METERING 3PH 40LFCSP

0

LTC2946CMS-1#TRPBF

LTC2946CMS-1#TRPBF

Analog Devices, Inc.

IC ENERGY MONITOR I2C 16MSOP

0

ADM1294-1BACPZ-RL7

ADM1294-1BACPZ-RL7

Analog Devices, Inc.

IC MONITOR QUAD UV/OV 16LFCSP

0

ADE7759ARSRL

ADE7759ARSRL

Analog Devices, Inc.

ACTIVE ENERGY METERING

3000

ADE7761AARS

ADE7761AARS

Analog Devices, Inc.

SINGLE PHASE ENERGY METERING IC

15660

LTC2946HMS#PBF

LTC2946HMS#PBF

Analog Devices, Inc.

IC ENERGY MONITOR I2C 16MSOP

2136

ADE7757ARN

ADE7757ARN

Analog Devices, Inc.

ENERGY MEASUREMENT

2075

ADM1293-1BARUZ-RL7

ADM1293-1BARUZ-RL7

Analog Devices, Inc.

IC MONITOR QUAD UV/OV 14TSSOP

0

ADE7751ARS

ADE7751ARS

Analog Devices, Inc.

SINGLE-PHASE ENERGY MEASUREMENT

7032

ADM1294-1BACPZ

ADM1294-1BACPZ

Analog Devices, Inc.

IC MONITOR QUAD UV/OV 16LFCSP

20

ADE5566ASTZF62

ADE5566ASTZF62

Analog Devices, Inc.

IC ENERGY METERING 1PHASE 64LQFP

0

PMIC - Energy Metering

1. Overview

Power Management Integrated Circuits (PMICs) with Energy Metering functionality are specialized semiconductor devices designed to monitor, measure, and manage electrical energy consumption in real-time. These ICs integrate analog front-ends (AFEs), high-precision analog-to-digital converters (ADCs), and digital signal processing units to quantify parameters like voltage, current, power, and energy (Wh/VAh). They play a critical role in modern energy-efficient systems, enabling precise energy auditing, load optimization, and compliance with regulatory standards (e.g., IEEE 1459, IEC 62053). Applications span smart grids, industrial automation, and IoT devices.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Single-Phase Energy Metering ICsMeasure voltage/current in single-phase AC systems, support 24-bit ADC, harmonic analysisResidential smart meters, home energy monitors
Three-Phase Energy Metering ICsMulti-channel measurement, phase imbalance detection, 0.1% accuracyIndustrial power distribution systems, EV charging stations
Isolated Energy Metering ICsGalvanic isolation up to 5kV, integrated DC/DC convertersHigh-voltage motor drives, grid-tied inverters
Low-Power Energy Metering ICsSub-10 A standby current, integrated energy accumulation registersBattery-powered sensors, portable diagnostics tools

3. Structure and Components

A typical PMIC - Energy Metering device comprises:

  • Analog Front-End (AFE): Differential amplifiers for current/voltage sensing
  • ADC Module: High-resolution (24-bit ) converters for signal digitization
  • DSP Core: Real-time computation of RMS values, THD, and energy accumulation
  • Communication Interfaces: SPI, I2C, UART for host connectivity
  • Calibration Logic: Digital registers for gain/offset compensation
The physical package ranges from QFN (4x4 mm) for low-power variants to HTSSOP for high-channel-density designs.

4. Key Technical Specifications

ParameterDescriptionImportance
Measurement AccuracyTypically 0.1% to 0.5% over temperatureDetermines billing accuracy in utility meters
Dynamic Range1000:1 to 3000:1 current/voltage ratioEnables detection of micro-leakage currents
Harmonics SupportUp to 21st order harmonic analysisCritical for power quality assessment
Temperature Stability 50ppm/ C drift compensationEnsures reliability in harsh environments
Communication ProtocolModbus, DLMS/COSEM, proprietary protocolsAffects system integration complexity

5. Application Fields

Main industries and equipment:

  • Energy Infrastructure: Smart electricity meters, grid analyzers
  • Industrial Automation: Motor control systems, programmable logic controllers (PLCs)
  • Consumer Electronics: Smart plugs, energy-efficient appliances
  • Data Centers: Server rack power monitoring, UPS systems
  • Renewables: Solar inverters, wind turbine condition monitoring
Case Study: Texas Instruments' AMC1304M25 is used in EV charging stations for 0.25% accuracy energy billing.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Analog DevicesAD7768-124-bit ADC, 256kSPS, integrated digital filter
STMicroelectronicsSTPM34Three-phase metering, IEC 62053-23 compliant
Silan MicroelectronicsSM2301Low-cost single-phase IC with UART interface
NXP SemiconductorsMCZ3301Automotive-grade, 0.05% accuracy for HEV/PHEV

7. Selection Guidelines

Key considerations:

  • Accuracy Requirements: 0.1% for utility-grade meters vs. 1% for diagnostics
  • Environmental Conditions: Industrial (-40 C to +85 C) vs. commercial (0 C to 70 C)
  • Integration Level: Standalone ICs vs. System-on-Chip (SoC) with MCU cores
  • Cost Constraints: Discrete ADC+MCU solutions vs. dedicated energy metering SoCs
Recommendation: For solar inverters, prioritize isolation ratings (>2.5kVRMS) and temperature stability.

8. Industry Trends

Future directions include:

  • AI-enhanced metering: On-chip machine learning for anomaly detection
  • Wireless integration: PMICs with BLE/Zigbee for IoT edge devices
  • Wide Bandgap Compatibility: GaN/SiC FET co-design for EV applications
  • Standardization: Unified firmware stacks for IEC 61850-10 compliance
Market growth is projected at 8.2% CAGR (2023-2030), driven by smart grid deployments and data center energy mandates.

RFQ BOM Call Skype Email
Top