Data Acquisition - Digital Potentiometers

Image Part Number Description / PDF Quantity Rfq
AD5161BRM100

AD5161BRM100

Analog Devices, Inc.

256-POSN. SPI/I2C DIGI-POT

10093

AD5115BCPZ80-500R7

AD5115BCPZ80-500R7

Analog Devices, Inc.

IC DGTL POT 80KOHM 32TAP 8LFCSP

479

MAX5454EUB+

MAX5454EUB+

Analog Devices, Inc.

MAX5454 DUAL, 256-TAP, UP/DOWN I

3730

DS3503U+TR

DS3503U+TR

Analog Devices, Inc.

NV, I2C, STEPPER POTENTIOMETER

3000

AD5243BRM100

AD5243BRM100

Analog Devices, Inc.

DUAL 256-POSITION I2C DIGI-POT

358

AD5282BRUZ20-REEL7

AD5282BRUZ20-REEL7

Analog Devices, Inc.

IC DGT POT 20KOHM 256TAP 16TSSOP

0

AD5242BRUZ10

AD5242BRUZ10

Analog Devices, Inc.

IC DGT POT 10KOHM 256TAP 16TSSOP

623

AD5270BRMZ-100-RL7

AD5270BRMZ-100-RL7

Analog Devices, Inc.

IC DGT RHE 100KOHM 1024TP 10MSOP

2669

AD8403AN50

AD8403AN50

Analog Devices, Inc.

SERIAL DIGI-POT 256 POSITIONS

8224

MAX5401EKA-T

MAX5401EKA-T

Analog Devices, Inc.

256-TAP DIGIPOT

10000

AD8403ARU50-REEL

AD8403ARU50-REEL

Analog Devices, Inc.

SERIAL DIGI-POT 256 POSITIONS

1639

DS1802

DS1802

Analog Devices, Inc.

DUAL AUDIO TAPER POT

302

MAX5160LEUA

MAX5160LEUA

Analog Devices, Inc.

MAX5160 LOW-POWER DIGIPOT

18600

AD5115BCPZ10-500R7

AD5115BCPZ10-500R7

Analog Devices, Inc.

IC DGTL POT 10KOHM 32TAP 8LFCSP

154

AD5248BRM2.5

AD5248BRM2.5

Analog Devices, Inc.

DUAL 256-POSITION I2C DIGI-POT

8426

AD5270BRMZ-20

AD5270BRMZ-20

Analog Devices, Inc.

IC DGT RHE 20KOHM 1024TAP 10MSOP

412

AD5290YRMZ10

AD5290YRMZ10

Analog Devices, Inc.

IC DGTL POT 10KOHM 256TAP 10MSOP

1421

DS1868E-10

DS1868E-10

Analog Devices, Inc.

DIGITAL POT, 10000OHM,

1515

DS1844E-050

DS1844E-050

Analog Devices, Inc.

DS1844 QUAD DIGIPOT

911

DS1669S-50

DS1669S-50

Analog Devices, Inc.

ELECTRONIC DIGITAL RHEOSTAT

421

Data Acquisition - Digital Potentiometers

1. Overview

Digital Potentiometers (DPOTs) are electronically controlled variable resistors that mimic the functionality of mechanical potentiometers. They enable precise adjustment of resistance values through digital signals, eliminating manual tuning. As critical components in data acquisition systems, DPOTs provide programmable control for analog circuits, enabling dynamic calibration, signal conditioning, and system optimization. Their importance lies in enhancing system reliability, reducing size, and enabling automated adjustments in applications ranging from industrial automation to consumer electronics.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Non-Volatile DPOTRetains resistance settings after power loss (uses EEPROM or flash memory)Industrial sensors, calibration systems
Volatile DPOTResets to default value when powered off (lower cost)Audio volume control, temporary signal adjustment
Multi-Channel DPOTIntegrates multiple independent potentiometers in one packageColor calibration in displays, multi-axis sensor systems
High-Resolution DPOTOffers 10-16 bit resolution for precise adjustmentsMedical imaging equipment, precision test instruments
Low-Voltage DPOTOperates at 1.8V-3.3V supply voltagesPortable devices, battery-powered systems

3. Structure and Components

A typical DPOT consists of:

  • Resistor Array: Precision thin-film or polysilicon resistors with laser-trimmed accuracy
  • Digital Control Logic: I C, SPI, or up/down interfaces for programming
  • Wiper Network: CMOS switches selecting tap points on resistor array
  • Memory Units: EEPROM/non-volatile memory for storing wiper positions
  • Power Management Circuitry: Voltage regulators and ESD protection
The CMOS-based architecture allows integration with analog front-end circuits in data acquisition systems.

4. Key Technical Specifications

ParameterDescriptionImportance
Resolution (bits)Number of discrete resistance steps (8-16 bit)Determines adjustment precision
Max Resistance (k )Full-scale resistance range (1k-1M )Affects signal amplitude handling
Interface TypeI C, SPI, PMBus, or push-button controlDictates system compatibility
Temperature Coefficient (ppm/ C)Resistance stability over temperature (5-50 ppm)Impacts measurement accuracy
Supply Voltage (V)Operating voltage range (2.7-5.5V)Defines power requirements
Power ConsumptionTypical/standby current (10-100 A)Crucial for battery-powered devices

5. Application Areas

  • Industrial: Sensor calibration, motor control, process automation
  • Consumer Electronics: Smartphones (display brightness), audio equipment
  • Medical: Patient monitoring devices, lab instruments
  • Automotive: Dashboard controls, ADAS sensor calibration
  • Test Equipment: Oscilloscopes, multimeters, signal generators

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
Analog DevicesAD5242/AD529012-bit resolution, I C interface, 1M range
Texas InstrumentsDSP0801/DS1803Dual-channel, 256-step resolution
Maxim IntegratedMCP4131/MAX5426SPI interface, 10V operation, 10k -50k
Analog MicroelectronicsAMT2210Non-volatile, 10k , industrial temperature range
STMicroelectronicsM95040/M95M014-wire SPI, 128-tap, automotive qualified

7. Selection Guidelines

Key considerations include:

  1. Resolution requirements for desired precision
  2. Memory type (non-volatile vs. volatile)
  3. Interface compatibility with system controllers
  4. Environmental factors (temperature range, vibration)
  5. Package type (SOIC, TSSOP, WLCSP for space constraints)
  6. Cost vs. performance trade-offs
For critical applications like medical devices, prioritize stability and temperature coefficient. For consumer products, focus on cost and package size.

8. Industry Trends

Future developments include:

  • Integration with ADC/DAC functions in single-chip solutions
  • AI-driven self-calibration algorithms for autonomous systems
  • Sub-1V operation for ultra-low-power IoT edge devices
  • Advanced packaging (3D stacking) for higher channel density
  • Increased adoption of IO-Link interfaces for industrial automation
Market growth is projected at 6.8% CAGR through 2027, driven by demand in industrial IoT and automotive electronics.

9. Application Case Studies

Case 1: In industrial pressure sensors, the AD5242 is used to calibrate offset voltage drift, achieving 0.1% accuracy over 0-100 C. Case 2: Consumer-grade smart speakers employ TI's TPL0401 for digitally controlled audio amplifiers, enabling 0.5dB step volume adjustment. Case 3: Medical infusion pumps use Maxim's DS1803 to maintain 0.5% flow rate accuracy through temperature variations.

RFQ BOM Call Skype Email
Top