Monitor - Current/Voltage Transducer

Image Part Number Description / PDF Quantity Rfq
P52000K11-M5M/11

P52000K11-M5M/11

Knick Interface

VOLTAGE TRANSDUCER 2000 VDC

10

P43100D2-0005

P43100D2-0005

Knick Interface

CURRENT TRANSDUCER 3600 VDC

5

P41000D1-S024

P41000D1-S024

Knick Interface

CURRENT TRANSDUCER 2200 VDC

9

P42100D3-0003

P42100D3-0003

Knick Interface

VOLTAGE TRANSDUCER 3600 VDC

5

P51000K11-M1M/11

P51000K11-M1M/11

Knick Interface

CURRENT TRANSDUCER 2000 VDC

10

P42000D2

P42000D2

Knick Interface

VOLTAGE TRANSDUCER 2200 VDC

10

P43000D2

P43000D2

Knick Interface

CURRENT TRANSDUCER 2200 VDC

5

P42001D3

P42001D3

Knick Interface

VOLTAGE TRANSDUCER 2200 VDC

10

P52100K11-M5M/11

P52100K11-M5M/11

Knick Interface

VOLTAGE TRANSDUCER 4800 VDC

10

P51000K11-M2M/11

P51000K11-M2M/11

Knick Interface

CURRENT TRANSDUCER 2000 VDC

10

P51100K11-M1M/11

P51100K11-M1M/11

Knick Interface

CURRENT TRANSDUCER 4800 VDC

10

P41100D1-0028

P41100D1-0028

Knick Interface

CURRENT TRANSDUCER 3600 VDC

5

P42000D3

P42000D3

Knick Interface

VOLTAGE TRANSDUCER 2200 VDC

10

P29001P2/01

P29001P2/01

Knick Interface

CURRENT TRANSDUCER 1000 VDC

7

P51100K11-M2M/11

P51100K11-M2M/11

Knick Interface

CURRENT TRANSDUCER 4800 VDC

10

P42000D3-S043

P42000D3-S043

Knick Interface

VOLTAGE TRANSDUCER 2200 VDC

10

P41000D1

P41000D1

Knick Interface

CURRENT TRANSDUCER 2200 VDC

5

P41000D1-0121

P41000D1-0121

Knick Interface

CURRENT TRANSDUCER 2200 VDC

10

P52100K11-M6M/11

P52100K11-M6M/11

Knick Interface

VOLTAGE TRANSDUCER 4800 VDC

10

P29000P2/01

P29000P2/01

Knick Interface

VOLTAGE TRANSDUCER 1000 VDC

8

Monitor - Current/Voltage Transducer

1. Overview

Current/Voltage Transducers are critical components in industrial automation systems that convert high-voltage or high-current signals into standardized low-level electrical signals (e.g., 4-20mA, 0-10V). These devices enable safe, accurate monitoring and control of electrical parameters in machinery, power systems, and process equipment. Their importance lies in ensuring operational efficiency, preventing equipment damage, and supporting data-driven decision-making in smart manufacturing and energy management systems.

2. Main Types and Functional Classification

Type Functional Characteristics Application Examples
Current Transducer Measures AC/DC current via Hall effect or shunt resistor, outputs proportional analog signal Motor load monitoring, battery management systems
Voltage Transducer Steps down high voltages (up to 1000VAC) to safe measurement levels with galvanic isolation Grid power quality analysis, transformer monitoring
Multi-Function Transducer Simultaneously measures voltage, current, power, and harmonics with digital communication Smart energy meters, industrial IoT gateways

3. Structure and Components

Typical construction includes:

  • Sensor Element: Hall effect ICs for non-contact current sensing or precision resistors for voltage division
  • Signal Conditioning Circuit: Amplifiers, filters, and isolation barriers (e.g., optocouplers or magnetic isolation)
  • Output Module: Analog-to-digital converters (ADC) or standard analog output drivers
  • Enclosure: Industrial-grade plastic/metal housing with IP65+ protection rating

4. Key Technical Specifications

Parameter Typical Range Importance
Input Range 0-5000A (current), 0-1000V (voltage) Determines measurement scope and application suitability
Output Signal 4-20mA, 0-10V, Modbus RTU Dictates compatibility with control systems
Accuracy Class 0.1% to 1.0% of reading Impacts measurement reliability and process control precision
Isolation Voltage 2.5kVAC to 6kVAC Ensures operator safety and system protection

5. Application Fields

  • Manufacturing: CNC machine monitoring, robotic arm power control
  • Energy: Smart grid metering, renewable energy inverters
  • Building Automation: HVAC system load balancing
  • Transportation: Electric vehicle charging station monitoring

Case Study: In a solar power plant, voltage transducers monitor PV array output to optimize inverter efficiency, improving energy yield by 8%.

6. Leading Manufacturers and Products

Manufacturer Representative Product Key Features
Siemens 7KE 6426 True RMS measurement, 0.2% accuracy, PROFINET interface
ABB CM-IWN Multi-range input, plug-and-play configuration
Schneider Electric iCT series Split-core design for retrofit installations, up to 1250A

7. Selection Recommendations

  • Determine required measurement range with 20% safety margin
  • Select output type matching PLC/DCS input modules
  • Consider environmental factors (temperature, humidity, EMI)
  • Prioritize devices with industry certifications (UL, CE, IEC 61010)
  • Evaluate total cost of ownership (installation, maintenance, lifespan)

8. Industry Trends

Key development directions include:

  • Integration with industrial IoT platforms via OPC UA and MQTT protocols
  • Adoption of wireless sensing technologies (e.g., Zigbee, 5G) for retrofit applications
  • Advancements in optical current sensing for high-voltage systems
  • Embedded AI algorithms for predictive maintenance capabilities
  • Miniaturization for space-constrained applications in robotics and EVs
RFQ BOM Call Skype Email