Monitor - Current/Voltage Transducer

Image Part Number Description / PDF Quantity Rfq
CR4510-250

CR4510-250

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

12

CR4820-500

CR4820-500

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

0

CR4810-250

CR4810-250

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

0

CR4550-150

CR4550-150

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

0

CR4510-500

CR4510-500

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

1

CR4510-50

CR4510-50

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

2

CR4640-150

CR4640-150

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

0

CR4520-150

CR4520-150

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

0

CR4560-500

CR4560-500

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

0

CR4820-150

CR4820-150

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

0

CR4580-150

CR4580-150

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

0

CR4820-250

CR4820-250

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

0

CR4510-150

CR4510-150

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

14

CR4820-50

CR4820-50

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

0

CR4820-20

CR4820-20

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

0

CR4820-600

CR4820-600

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

0

CR4620-150

CR4620-150

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

0

CR4550-500

CR4550-500

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

11

CR4880-250

CR4880-250

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

0

CR4550-250

CR4550-250

CR Magnetics, Inc.

TRANSDUCER VOLTAGE 24VDC

0

Monitor - Current/Voltage Transducer

1. Overview

Current/Voltage Transducers are critical components in industrial automation systems that convert high-voltage or high-current signals into standardized low-level electrical signals (e.g., 4-20mA, 0-10V). These devices enable safe, accurate monitoring and control of electrical parameters in machinery, power systems, and process equipment. Their importance lies in ensuring operational efficiency, preventing equipment damage, and supporting data-driven decision-making in smart manufacturing and energy management systems.

2. Main Types and Functional Classification

Type Functional Characteristics Application Examples
Current Transducer Measures AC/DC current via Hall effect or shunt resistor, outputs proportional analog signal Motor load monitoring, battery management systems
Voltage Transducer Steps down high voltages (up to 1000VAC) to safe measurement levels with galvanic isolation Grid power quality analysis, transformer monitoring
Multi-Function Transducer Simultaneously measures voltage, current, power, and harmonics with digital communication Smart energy meters, industrial IoT gateways

3. Structure and Components

Typical construction includes:

  • Sensor Element: Hall effect ICs for non-contact current sensing or precision resistors for voltage division
  • Signal Conditioning Circuit: Amplifiers, filters, and isolation barriers (e.g., optocouplers or magnetic isolation)
  • Output Module: Analog-to-digital converters (ADC) or standard analog output drivers
  • Enclosure: Industrial-grade plastic/metal housing with IP65+ protection rating

4. Key Technical Specifications

Parameter Typical Range Importance
Input Range 0-5000A (current), 0-1000V (voltage) Determines measurement scope and application suitability
Output Signal 4-20mA, 0-10V, Modbus RTU Dictates compatibility with control systems
Accuracy Class 0.1% to 1.0% of reading Impacts measurement reliability and process control precision
Isolation Voltage 2.5kVAC to 6kVAC Ensures operator safety and system protection

5. Application Fields

  • Manufacturing: CNC machine monitoring, robotic arm power control
  • Energy: Smart grid metering, renewable energy inverters
  • Building Automation: HVAC system load balancing
  • Transportation: Electric vehicle charging station monitoring

Case Study: In a solar power plant, voltage transducers monitor PV array output to optimize inverter efficiency, improving energy yield by 8%.

6. Leading Manufacturers and Products

Manufacturer Representative Product Key Features
Siemens 7KE 6426 True RMS measurement, 0.2% accuracy, PROFINET interface
ABB CM-IWN Multi-range input, plug-and-play configuration
Schneider Electric iCT series Split-core design for retrofit installations, up to 1250A

7. Selection Recommendations

  • Determine required measurement range with 20% safety margin
  • Select output type matching PLC/DCS input modules
  • Consider environmental factors (temperature, humidity, EMI)
  • Prioritize devices with industry certifications (UL, CE, IEC 61010)
  • Evaluate total cost of ownership (installation, maintenance, lifespan)

8. Industry Trends

Key development directions include:

  • Integration with industrial IoT platforms via OPC UA and MQTT protocols
  • Adoption of wireless sensing technologies (e.g., Zigbee, 5G) for retrofit applications
  • Advancements in optical current sensing for high-voltage systems
  • Embedded AI algorithms for predictive maintenance capabilities
  • Miniaturization for space-constrained applications in robotics and EVs