Monitor - Current/Voltage Transducer

Image Part Number Description / PDF Quantity Rfq
ENTUBE DE (500V 5V)

ENTUBE DE (500V 5V)

Verivolt

TRANSDUCER VOLTAGE HIBAND

0

ENTUBE TE (100V 5V)

ENTUBE TE (100V 5V)

Verivolt

TRANSDUCER VOLTAGE DIVIDER 3PH

0

ISOBLOCK V-1C (1000V 10V)

ISOBLOCK V-1C (1000V 10V)

Verivolt

TRANSDUCER VOLTAGE 9-28VDC

61

ENTUBE QE (750V 10V L-L)

ENTUBE QE (750V 10V L-L)

Verivolt

TRANSDUCER VOLTAGE DIVIDER

0

ISOBLOCK V-4C (250VAC 7VAC)

ISOBLOCK V-4C (250VAC 7VAC)

Verivolt

TRANSDUCER VOLTAGE 9-28VDC

0

ISOBLOCK V-4C (50V 5V)

ISOBLOCK V-4C (50V 5V)

Verivolt

TRANSDUCER VOLTAGE 9-28VDC

0

ENTUBE SE (100V 10V)

ENTUBE SE (100V 10V)

Verivolt

TRANSDUCER VOLTAGE DIVIDER

1

ENTUBE TE (150VAC 7VAC)

ENTUBE TE (150VAC 7VAC)

Verivolt

TRANSDUCER VOLTAGE DIVIDER 3PH

0

ENTUBE DE (1500V 10V)

ENTUBE DE (1500V 10V)

Verivolt

TRANSDUCER VOLTAGE HIBAND

1

ENTUBE DE-HB (500V1V SESC)

ENTUBE DE-HB (500V1V SESC)

Verivolt

TRANSDUCER VOLTAGE 9-28VDC

0

ENTUBE DE-HB (1500V 5V DIFFSC)

ENTUBE DE-HB (1500V 5V DIFFSC)

Verivolt

TRANSDUCER VOLTAGE 9-28VDC

0

ENTUBE QE (500VAC 7VAC L-L)

ENTUBE QE (500VAC 7VAC L-L)

Verivolt

TRANSDUCER VOLTAGE DIVIDER

0

ISOBLOCK V-1C (50V 5V)

ISOBLOCK V-1C (50V 5V)

Verivolt

TRANSDUCER VOLTAGE 9-28VDC

2

ISOBLOCK V-4C (50V 10V0.1%)

ISOBLOCK V-4C (50V 10V0.1%)

Verivolt

TRANSDUCER VOLTAGE 9-28VDC

0

ENTUBE DE-HB (300V1V SESC)

ENTUBE DE-HB (300V1V SESC)

Verivolt

TRANSDUCER VOLTAGE 9-28VDC

0

ENTUBE SE STD (3000V 10V)

ENTUBE SE STD (3000V 10V)

Verivolt

TRANSDUCER VOLTAGE DIVIDER

0

ENTUBE Z (300V 2V)

ENTUBE Z (300V 2V)

Verivolt

TRANSDUCER VOLTAGE DIVIDER

0

ENTUBE DE-HB (50V 10V SESC)

ENTUBE DE-HB (50V 10V SESC)

Verivolt

TRANSDUCER VOLTAGE 9-28VDC

0

ISOBLOCK V-4C (500VAC 7VAC0.1%)

ISOBLOCK V-4C (500VAC 7VAC0.1%)

Verivolt

TRANSDUCER VOLTAGE 9-28VDC

0

ENTUBE QE (150VAC 7VAC L-N)

ENTUBE QE (150VAC 7VAC L-N)

Verivolt

TRANSDUCER VOLTAGE DIVIDER

0

Monitor - Current/Voltage Transducer

1. Overview

Current/Voltage Transducers are critical components in industrial automation systems that convert high-voltage or high-current signals into standardized low-level electrical signals (e.g., 4-20mA, 0-10V). These devices enable safe, accurate monitoring and control of electrical parameters in machinery, power systems, and process equipment. Their importance lies in ensuring operational efficiency, preventing equipment damage, and supporting data-driven decision-making in smart manufacturing and energy management systems.

2. Main Types and Functional Classification

Type Functional Characteristics Application Examples
Current Transducer Measures AC/DC current via Hall effect or shunt resistor, outputs proportional analog signal Motor load monitoring, battery management systems
Voltage Transducer Steps down high voltages (up to 1000VAC) to safe measurement levels with galvanic isolation Grid power quality analysis, transformer monitoring
Multi-Function Transducer Simultaneously measures voltage, current, power, and harmonics with digital communication Smart energy meters, industrial IoT gateways

3. Structure and Components

Typical construction includes:

  • Sensor Element: Hall effect ICs for non-contact current sensing or precision resistors for voltage division
  • Signal Conditioning Circuit: Amplifiers, filters, and isolation barriers (e.g., optocouplers or magnetic isolation)
  • Output Module: Analog-to-digital converters (ADC) or standard analog output drivers
  • Enclosure: Industrial-grade plastic/metal housing with IP65+ protection rating

4. Key Technical Specifications

Parameter Typical Range Importance
Input Range 0-5000A (current), 0-1000V (voltage) Determines measurement scope and application suitability
Output Signal 4-20mA, 0-10V, Modbus RTU Dictates compatibility with control systems
Accuracy Class 0.1% to 1.0% of reading Impacts measurement reliability and process control precision
Isolation Voltage 2.5kVAC to 6kVAC Ensures operator safety and system protection

5. Application Fields

  • Manufacturing: CNC machine monitoring, robotic arm power control
  • Energy: Smart grid metering, renewable energy inverters
  • Building Automation: HVAC system load balancing
  • Transportation: Electric vehicle charging station monitoring

Case Study: In a solar power plant, voltage transducers monitor PV array output to optimize inverter efficiency, improving energy yield by 8%.

6. Leading Manufacturers and Products

Manufacturer Representative Product Key Features
Siemens 7KE 6426 True RMS measurement, 0.2% accuracy, PROFINET interface
ABB CM-IWN Multi-range input, plug-and-play configuration
Schneider Electric iCT series Split-core design for retrofit installations, up to 1250A

7. Selection Recommendations

  • Determine required measurement range with 20% safety margin
  • Select output type matching PLC/DCS input modules
  • Consider environmental factors (temperature, humidity, EMI)
  • Prioritize devices with industry certifications (UL, CE, IEC 61010)
  • Evaluate total cost of ownership (installation, maintenance, lifespan)

8. Industry Trends

Key development directions include:

  • Integration with industrial IoT platforms via OPC UA and MQTT protocols
  • Adoption of wireless sensing technologies (e.g., Zigbee, 5G) for retrofit applications
  • Advancements in optical current sensing for high-voltage systems
  • Embedded AI algorithms for predictive maintenance capabilities
  • Miniaturization for space-constrained applications in robotics and EVs
RFQ BOM Call Skype Email
Top