| Image | Part Number | Description / PDF | Quantity | Rfq |
|---|---|---|---|---|
|
Verivolt |
TRANSDUCER VOLTAGE HIBAND |
0 |
|
|
|
Verivolt |
TRANSDUCER VOLTAGE DIVIDER 3PH |
0 |
|
|
|
CR Magnetics, Inc. |
TRANSDUCER VOLTAGE 24VDC |
12 |
|
|
|
CR Magnetics, Inc. |
TRANSDUCER VOLTAGE 24VDC |
0 |
|
|
|
Verivolt |
TRANSDUCER VOLTAGE 9-28VDC |
61 |
|
|
|
Phoenix Contact |
TRANSDUCER CURRENT 20-30VDC |
0 |
|
|
|
Knick Interface |
VOLTAGE TRANSDUCER 2000 VDC |
10 |
|
|
|
CR Magnetics, Inc. |
TRANSDUCER VOLTAGE 24VDC |
0 |
|
|
|
Verivolt |
TRANSDUCER VOLTAGE DIVIDER |
0 |
|
|
|
Verivolt |
TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
|
|
Verivolt |
TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
|
|
Verivolt |
TRANSDUCER VOLTAGE DIVIDER |
1 |
|
|
|
Knick Interface |
CURRENT TRANSDUCER 3600 VDC |
5 |
|
|
|
Verivolt |
TRANSDUCER VOLTAGE DIVIDER 3PH |
0 |
|
|
|
Verivolt |
TRANSDUCER VOLTAGE HIBAND |
1 |
|
|
|
Carlo Gavazzi |
TRANSDUCER VOLTAGE 90-260VAC/DC |
3 |
|
|
|
Verivolt |
TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
|
|
ENTUBE DE-HB (1500V 5V DIFFSC) Verivolt |
TRANSDUCER VOLTAGE 9-28VDC |
0 |
|
|
|
Verivolt |
TRANSDUCER VOLTAGE DIVIDER |
0 |
|
|
|
Verivolt |
TRANSDUCER VOLTAGE 9-28VDC |
2 |
|
Current/Voltage Transducers are critical components in industrial automation systems that convert high-voltage or high-current signals into standardized low-level electrical signals (e.g., 4-20mA, 0-10V). These devices enable safe, accurate monitoring and control of electrical parameters in machinery, power systems, and process equipment. Their importance lies in ensuring operational efficiency, preventing equipment damage, and supporting data-driven decision-making in smart manufacturing and energy management systems.
| Type | Functional Characteristics | Application Examples |
|---|---|---|
| Current Transducer | Measures AC/DC current via Hall effect or shunt resistor, outputs proportional analog signal | Motor load monitoring, battery management systems |
| Voltage Transducer | Steps down high voltages (up to 1000VAC) to safe measurement levels with galvanic isolation | Grid power quality analysis, transformer monitoring |
| Multi-Function Transducer | Simultaneously measures voltage, current, power, and harmonics with digital communication | Smart energy meters, industrial IoT gateways |
Typical construction includes:
| Parameter | Typical Range | Importance |
|---|---|---|
| Input Range | 0-5000A (current), 0-1000V (voltage) | Determines measurement scope and application suitability |
| Output Signal | 4-20mA, 0-10V, Modbus RTU | Dictates compatibility with control systems |
| Accuracy Class | 0.1% to 1.0% of reading | Impacts measurement reliability and process control precision |
| Isolation Voltage | 2.5kVAC to 6kVAC | Ensures operator safety and system protection |
Case Study: In a solar power plant, voltage transducers monitor PV array output to optimize inverter efficiency, improving energy yield by 8%.
| Manufacturer | Representative Product | Key Features |
|---|---|---|
| Siemens | 7KE 6426 | True RMS measurement, 0.2% accuracy, PROFINET interface |
| ABB | CM-IWN | Multi-range input, plug-and-play configuration |
| Schneider Electric | iCT series | Split-core design for retrofit installations, up to 1250A |
Key development directions include: