Arrays, Signal Transformers

Image Part Number Description / PDF Quantity Rfq
SRF1280-331M

SRF1280-331M

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 330UH SMD

722

SRF1260A-R47Y

SRF1260A-R47Y

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 470NH SMD

0

PM3604-15-RC

PM3604-15-RC

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 15UH SMD

2056

SRF0703-1R5M

SRF0703-1R5M

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 1.5UH SMD

135

PM3604-5-RC

PM3604-5-RC

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 5UH SMD

24

PM3604-300-RC

PM3604-300-RC

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 300UH SMD

557

SRF1260A-101M

SRF1260A-101M

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 100UH SMD

0

PM3602-5-RC

PM3602-5-RC

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 5UH SMD

1646

SRF1260-330M

SRF1260-330M

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 33UH SMD

1956

SRF1260-101M

SRF1260-101M

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 100UH SMD

0

SRF1260-4R7Y

SRF1260-4R7Y

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 4.7UH SMD

33545

SRF1260A-151M

SRF1260A-151M

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 150UH SMD

0

SRF0703A-8R2M

SRF0703A-8R2M

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 8.2UH SMD

43

SRF1260-681M

SRF1260-681M

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 680UH SMD

800

SRF1260-151M

SRF1260-151M

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 150UH SMD

549

SRF1280A-471M

SRF1280A-471M

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 470UH SMD

296

SRF1280-2R2Y

SRF1280-2R2Y

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 2.2UH SMD

253

PM3602-33-RC

PM3602-33-RC

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 33UH SMD

71

SRF0703-8R2M

SRF0703-8R2M

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 8.2UH SMD

2398

SRF1280-220M

SRF1280-220M

J.W. Miller / Bourns

INDUCT ARRAY 2 COIL 22UH SMD

5155

Arrays, Signal Transformers

1. Overview

Inductors, coils, chokes, arrays, and signal transformers are fundamental passive components in electronic systems. Inductors store energy in magnetic fields, chokes suppress high-frequency noise, arrays integrate multiple magnetic elements, and signal transformers enable voltage conversion and galvanic isolation. These components are critical in power management, signal processing, electromagnetic interference (EMI) mitigation, and communication systems. Their advancements drive miniaturization, efficiency, and performance in modern electronics.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Wire-wound InductorsHigh inductance values, low DC resistanceSwitching power supplies
Ferrite Bead ChokesHigh impedance at high frequenciesEMI filtering in USB interfaces
Common-mode Choke ArraysSuppress differential and common-mode noiseIndustrial motor drives
Signal TransformersGalvanic isolation, voltage scalingTelecom network interfaces
Thin-film Inductor ArraysUltra-low profile, tight couplingRF front-end modules

3. Structure and Composition

Typical structures include:

  • Inductors: Wound conductive wire (copper/enamelled aluminum) on magnetic cores (ferrite, powdered iron)
  • Chokes: Toroidal or drum cores with single/dual windings
  • Arrays: Monolithic integration of multiple chokes/inductors in single package
  • Signal Transformers: Primary/secondary coils with electrostatic shielding, E-I or toroidal cores

4. Key Technical Specifications

ParameterDescriptionImportance
Inductance (L)Defines energy storage capacity ( H-mH range)Determines filtering performance
Rated CurrentMax DC/AC current before saturationPrevents core saturation in power circuits
DCRDC resistance of windingsAffects power efficiency
Self-resonant FrequencyFrequency where parasitic capacitance dominatesLimits usable frequency range
Turns RatioPrimary/secondary winding ratioDefines voltage transformation ratio

5. Application Fields

Key industries:

  • Telecommunications: Base station power systems, optical transceivers
  • Consumer Electronics: Mobile chargers, LED drivers
  • Automotive: EV battery management systems, ADAS sensors
  • Industrial: Programmable logic controllers (PLCs), inverters

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductsKey Features
TDKINDUCTOR,Wire-wound: VLS6045EX6.0 4.5 4.5mm, 120A rated current
CoilcraftCommon-mode Choke: 1140081.8kV isolation, 100MHz bandwidth
BournsSignal Transformer: SM41121:1:1:1 ratio, 1500V isolation
Pulse ElectronicsLAN Transformer: HX4008NLIntegrated magnetics for Gigabit Ethernet
SumidaPower Choke: CDRH3D283.3 H-100 H, 125A peak current

7. Selection Guidelines

Consider:

  • Inductance value and tolerance ( 20% typical for power chokes)
  • Operating frequency vs. self-resonant frequency
  • Thermal management (temperature rise 40 C)
  • Package size (0402-2200 for surface-mount devices)
  • Isolation voltage ( 1.5kV for industrial applications)

8. Industry Trends

Emerging trends:

  • Miniaturization: 01005-sized inductors for wearable devices
  • High-frequency operation: Multi-GHz transformers for 5G infrastructure
  • Integrated magnetics: Combined inductors/transformers in SiP solutions
  • Advanced materials: Amorphous/nanocrystalline cores for high-efficiency EV chargers
  • Automotive-grade reliability: AEC-Q200 qualified components for e-mobility

RFQ BOM Call Skype Email
Top