Arrays, Signal Transformers

Image Part Number Description / PDF Quantity Rfq
CL-12-24

CL-12-24

Signal Transformer

INDUCT ARRAY 2COIL 1.2MH CHA MNT

0

CL-25-50

CL-25-50

Signal Transformer

INDUCT ARRAY 2COIL 300UH CHA MNT

20

CL-4-8

CL-4-8

Signal Transformer

INDUCT ARRAY 2 COIL 5MH CHA MNT

1

CL-2-4

CL-2-4

Signal Transformer

INDUCT ARRAY 2 COIL 10MH CHA MNT

0

CL-6-12

CL-6-12

Signal Transformer

INDUCT ARRAY 2 COIL 3MH CHA MNT

4

CL-50-100

CL-50-100

Signal Transformer

INDUCT ARRAY 2COIL 120UH CHA MNT

0

CL-1-2

CL-1-2

Signal Transformer

INDUCT ARRAY 2 COIL 18MH CHA MNT

4

SCX114-150

SCX114-150

Signal Transformer

INDUCT ARRAY 2 COIL 15UH SMD

0

SCRHB124B-1024

SCRHB124B-1024

Signal Transformer

INDUCT ARRAY 2 COIL 8.1UH SMD

0

SCX147-500

SCX147-500

Signal Transformer

INDUCT ARRAY 2 COIL 50UH SMD

0

SCRHB125-8222

SCRHB125-8222

Signal Transformer

INDUCT ARRAY 2 COIL 6.7UH SMD

0

SCX114-301

SCX114-301

Signal Transformer

INDUCT ARRAY 2 COIL 300UH SMD

0

SCX114-101

SCX114-101

Signal Transformer

INDUCT ARRAY 2 COIL 100UH SMD

0

SCX147-1R8

SCX147-1R8

Signal Transformer

INDUCT ARRAY 2 COIL 1.8UH SMD

0

SCRHB125-1022

SCRHB125-1022

Signal Transformer

INDUCT ARRAY 2 COIL 8.1UH SMD

0

SCX147-151

SCX147-151

Signal Transformer

INDUCT ARRAY 2 COIL 150UH SMD

0

SCRHB125B-1014

SCRHB125B-1014

Signal Transformer

INDUCT ARRAY 2 COIL 6.6UH SMD

0

SCRHB124-1024

SCRHB124-1024

Signal Transformer

INDUCT ARRAY 2 COIL 8.1UH SMD

0

SCX147-100

SCX147-100

Signal Transformer

INDUCT ARRAY 2 COIL 10UH SMD

0

SCRHB125-8220

SCRHB125-8220

Signal Transformer

INDUCT ARRAY 2 COIL 6.5UH SMD

0

Arrays, Signal Transformers

1. Overview

Inductors, coils, chokes, arrays, and signal transformers are fundamental passive components in electronic systems. Inductors store energy in magnetic fields, chokes suppress high-frequency noise, arrays integrate multiple magnetic elements, and signal transformers enable voltage conversion and galvanic isolation. These components are critical in power management, signal processing, electromagnetic interference (EMI) mitigation, and communication systems. Their advancements drive miniaturization, efficiency, and performance in modern electronics.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Wire-wound InductorsHigh inductance values, low DC resistanceSwitching power supplies
Ferrite Bead ChokesHigh impedance at high frequenciesEMI filtering in USB interfaces
Common-mode Choke ArraysSuppress differential and common-mode noiseIndustrial motor drives
Signal TransformersGalvanic isolation, voltage scalingTelecom network interfaces
Thin-film Inductor ArraysUltra-low profile, tight couplingRF front-end modules

3. Structure and Composition

Typical structures include:

  • Inductors: Wound conductive wire (copper/enamelled aluminum) on magnetic cores (ferrite, powdered iron)
  • Chokes: Toroidal or drum cores with single/dual windings
  • Arrays: Monolithic integration of multiple chokes/inductors in single package
  • Signal Transformers: Primary/secondary coils with electrostatic shielding, E-I or toroidal cores

4. Key Technical Specifications

ParameterDescriptionImportance
Inductance (L)Defines energy storage capacity ( H-mH range)Determines filtering performance
Rated CurrentMax DC/AC current before saturationPrevents core saturation in power circuits
DCRDC resistance of windingsAffects power efficiency
Self-resonant FrequencyFrequency where parasitic capacitance dominatesLimits usable frequency range
Turns RatioPrimary/secondary winding ratioDefines voltage transformation ratio

5. Application Fields

Key industries:

  • Telecommunications: Base station power systems, optical transceivers
  • Consumer Electronics: Mobile chargers, LED drivers
  • Automotive: EV battery management systems, ADAS sensors
  • Industrial: Programmable logic controllers (PLCs), inverters

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductsKey Features
TDKINDUCTOR,Wire-wound: VLS6045EX6.0 4.5 4.5mm, 120A rated current
CoilcraftCommon-mode Choke: 1140081.8kV isolation, 100MHz bandwidth
BournsSignal Transformer: SM41121:1:1:1 ratio, 1500V isolation
Pulse ElectronicsLAN Transformer: HX4008NLIntegrated magnetics for Gigabit Ethernet
SumidaPower Choke: CDRH3D283.3 H-100 H, 125A peak current

7. Selection Guidelines

Consider:

  • Inductance value and tolerance ( 20% typical for power chokes)
  • Operating frequency vs. self-resonant frequency
  • Thermal management (temperature rise 40 C)
  • Package size (0402-2200 for surface-mount devices)
  • Isolation voltage ( 1.5kV for industrial applications)

8. Industry Trends

Emerging trends:

  • Miniaturization: 01005-sized inductors for wearable devices
  • High-frequency operation: Multi-GHz transformers for 5G infrastructure
  • Integrated magnetics: Combined inductors/transformers in SiP solutions
  • Advanced materials: Amorphous/nanocrystalline cores for high-efficiency EV chargers
  • Automotive-grade reliability: AEC-Q200 qualified components for e-mobility

RFQ BOM Call Skype Email
Top