Power Line Filter Modules

Image Part Number Description / PDF Quantity Rfq
RP600-100-1000-S-B

RP600-100-1000-S-B

Astrodyne TDI

HIGH PERF DC PWR LINE FILTER

10

RP325-80-0-S

RP325-80-0-S

Astrodyne TDI

3PH DELTA DUAL STAGE PWR LINE FI

10

RP130-20-.47-S

RP130-20-.47-S

Astrodyne TDI

HIGH PERF SNGL STAGE PWR LINE FI

10

LF10

LF10

Astrodyne TDI

HIGH PERF LOW LEAKAGE SWITCH MOD

10

RP359-150-1000-W

RP359-150-1000-W

Astrodyne TDI

3PH DELTA MULTI-STAGE HIGH CURRE

10

RP600-30-100-S-B

RP600-30-100-S-B

Astrodyne TDI

HIGH PERF DC PWR LINE FILTER

10

3F3

3F3

Astrodyne TDI

HIGH PERF 3PH SWITCH MODE EMI FI

2

RP327-55-100-W

RP327-55-100-W

Astrodyne TDI

BOOKSHELF 3PH DELTA DUAL STAGE P

10

RP615-6-1000-W

RP615-6-1000-W

Astrodyne TDI

HIGH PERF DUAL STAGE DC PWR LINE

10

RP110-20-1-S

RP110-20-1-S

Astrodyne TDI

COMPACT SINGLE PH SNGL STAGE PWR

10

080SV.01500.00

080SV.01500.00

Astrodyne TDI

SNAP-IN SNGL STAGE IEC INLET FIL

10

RP415-160-100-C

RP415-160-100-C

Astrodyne TDI

3PH WYE COMPACT SNGL STAGE PWR L

10

RP420-15-10-W

RP420-15-10-W

Astrodyne TDI

3PH WYE DUAL STAGE PWR LINE FILT

10

RP327-55-100-S

RP327-55-100-S

Astrodyne TDI

BOOKSHELF 3PH DELTA DUAL STAGE P

10

RP135-1-1-QD

RP135-1-1-QD

Astrodyne TDI

HIGH PERF SNGL STAGE PWR LINE FI

10

RP230-3.5-4.7-QD

RP230-3.5-4.7-QD

Astrodyne TDI

HIGH PERF DUAL STAGE PWR LINE FI

33

RP380-100-0-S

RP380-100-0-S

Astrodyne TDI

3 PH DELTA PWR LINE FILTER 600V

10

RP357-2500-2000-B

RP357-2500-2000-B

Astrodyne TDI

3PH DELTA MULTI-STAGE HIGH CURRE

10

RP405-6-100-W

RP405-6-100-W

Astrodyne TDI

3PH WYE COMPACT SNGL STAGE PWR L

10

RP225-20-4.7-QD

RP225-20-4.7-QD

Astrodyne TDI

HIGH PERF DUAL STAGE PWR LINE FI

195

Power Line Filter Modules

1. Overview

Power Line Filter Modules (PLFMs) are electromagnetic interference (EMI) suppression devices designed to mitigate conducted noise in electrical systems. They ensure compliance with electromagnetic compatibility (EMC) standards by attenuating high-frequency noise while allowing desired power frequencies to pass. Their importance grows with increasing electrification and connectivity in modern applications like renewable energy systems, industrial automation, and medical electronics.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
Differential Mode FilterSuppresses asymmetric noise between live/neutral conductorsMotor drives, variable frequency drives
Common Mode FilterAttenuates symmetric noise between conductors and groundMedical imaging equipment, data centers
Combined FilterIntegrates differential and common mode suppressionIndustrial control cabinets, test equipment
High-Frequency FilterTargets noise above 1MHz with specialized componentsWireless base stations, satellite communication

3. Structure and Components

Typical PLFM construction includes: - Die-cast aluminum housing for EMI shielding - X/Y capacitors (ceramic or film type) for differential/common mode filtering - Toroidal or multi-hole inductors for noise suppression - Integrated thermal fuses and discharge resistors - IEC standard connectors (e.g., C13/C14) or terminal blocks - Epoxy sealing for environmental protection

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeTypically 150kHz-100MHzDetermines noise bandwidth attenuation
Voltage Rating100-600VAC/DCDefines operational safety margin
Insertion Loss10-100dB at target frequenciesQuantifies noise reduction capability
Current Capacity0.5-100AAffects power delivery capability
Temperature Range-40 C to +125 CEnsures environmental reliability

5. Application Areas

Key industries and equipment: - Industrial Automation: PLC control cabinets, CNC machines - Medical: MRI scanners, patient monitoring systems - Communication: 5G base stations, network servers - Renewable Energy: Solar inverters, wind turbine controllers - Aerospace: Avionics power systems, satellite payloads - Consumer Electronics: EV charging stations, smart home systems

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
SchaffnerFN 208080A rating, 3-phase filter for industrial drives
TDK-LambdaDFM1K1kW power line filter with medical safety certification
MTE CorporationPro-NetModular filter for industrial Ethernet applications
API TechnologiesPLF-300Military-grade filter for aerospace systems

7. Selection Guidelines

Key considerations: - Match voltage/current ratings with system requirements - Verify insertion loss curves at specific noise frequencies - Consider physical dimensions and cooling requirements - Ensure compliance with relevant standards (e.g., IEC 60939) - Evaluate environmental conditions (temperature, humidity, vibration) - Assess certification needs (CE, UL, MIL-STD)

8. Industry Trends

Market developments include: - Increasing demand for high-frequency filters (>10MHz) due to 5G/6G adoption - Miniaturization for EV and portable medical device applications - Integration with smart monitoring capabilities (IoT-enabled filters) - Growth in wide bandgap semiconductor compatible filters (SiC/GaN) - Stricter EMC regulations driving customized filter solutions - Market CAGR projected at 6.8% (2023-2030) according to industry reports