Power Line Filter Modules

Image Part Number Description / PDF Quantity Rfq
5500.2091

5500.2091

Schurter

LINE FILTER 125/250VAC 4A CHAS

21

FMAB-N7PH-0646

FMAB-N7PH-0646

Schurter

HV FILTER 1PH 1ST N 6A 277VAC M8

0

FMBC-0995-3600

FMBC-0995-3600

Schurter

LINE FILTER 480VAC 36A CHASS MNT

0

FMBC-R91R-4212

FMBC-R91R-4212

Schurter

FMBC LL FILTER 3PH 2ST 42A 520VA

0

5500.2635.04

5500.2635.04

Schurter

LINE FILTER 125/250VAC 10A CHASS

16

FMBC-0932-2510L

FMBC-0932-2510L

Schurter

LINE FILTER 480VAC 25A CHASS MNT

3

FMAC-091G-H110

FMAC-091G-H110

Schurter

LINE FILTER 480VAC 110A CHASS

0

5500.2125

5500.2125

Schurter

LINE FILTER 125/250VAC 1A TH

20

FPBB-V6TI-1090

FPBB-V6TI-1090

Schurter

LINE FILTER 250VDC/VAC 10A CHAS

0

5500.2116

5500.2116

Schurter

LINE FILTER 125/250VAC 600MA TH

0

5500.2048

5500.2048

Schurter

LINE FILTER 125/250VAC 4A CHAS

3

5500.2651.04

5500.2651.04

Schurter

LINE FILTER 125/250VAC 3A CHAS

15

FMAD-36SZ-2042.HP

FMAD-36SZ-2042.HP

Schurter

FMAD CP FILT 3PH+N 1ST 20A 520VA

10

FMBB-36ME-2040

FMBB-36ME-2040

Schurter

FMBB EP FILTER 1PH 2ST 20A 250VA

106

5500.2103

5500.2103

Schurter

LINE FILTER 125/250VAC 10A CHASS

0

FMAD-0931-1610

FMAD-0931-1610

Schurter

LINE FILTER 277/480VAC 16A CHASS

0

FMAC-0954-H110

FMAC-0954-H110

Schurter

LINE FILTER 480/520VAC 110A CHAS

2

5500.2060

5500.2060

Schurter

LINE FILTER 125/250VAC 6A CHAS

40

5500.2656.04

5500.2656.04

Schurter

LINE FILTER 125/250VAC 20A CHASS

10

5500.2645.01

5500.2645.01

Schurter

LINE FILTER 125/250VAC 16A CHASS

13

Power Line Filter Modules

1. Overview

Power Line Filter Modules (PLFMs) are electromagnetic interference (EMI) suppression devices designed to mitigate conducted noise in electrical systems. They ensure compliance with electromagnetic compatibility (EMC) standards by attenuating high-frequency noise while allowing desired power frequencies to pass. Their importance grows with increasing electrification and connectivity in modern applications like renewable energy systems, industrial automation, and medical electronics.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
Differential Mode FilterSuppresses asymmetric noise between live/neutral conductorsMotor drives, variable frequency drives
Common Mode FilterAttenuates symmetric noise between conductors and groundMedical imaging equipment, data centers
Combined FilterIntegrates differential and common mode suppressionIndustrial control cabinets, test equipment
High-Frequency FilterTargets noise above 1MHz with specialized componentsWireless base stations, satellite communication

3. Structure and Components

Typical PLFM construction includes: - Die-cast aluminum housing for EMI shielding - X/Y capacitors (ceramic or film type) for differential/common mode filtering - Toroidal or multi-hole inductors for noise suppression - Integrated thermal fuses and discharge resistors - IEC standard connectors (e.g., C13/C14) or terminal blocks - Epoxy sealing for environmental protection

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeTypically 150kHz-100MHzDetermines noise bandwidth attenuation
Voltage Rating100-600VAC/DCDefines operational safety margin
Insertion Loss10-100dB at target frequenciesQuantifies noise reduction capability
Current Capacity0.5-100AAffects power delivery capability
Temperature Range-40 C to +125 CEnsures environmental reliability

5. Application Areas

Key industries and equipment: - Industrial Automation: PLC control cabinets, CNC machines - Medical: MRI scanners, patient monitoring systems - Communication: 5G base stations, network servers - Renewable Energy: Solar inverters, wind turbine controllers - Aerospace: Avionics power systems, satellite payloads - Consumer Electronics: EV charging stations, smart home systems

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Features
SchaffnerFN 208080A rating, 3-phase filter for industrial drives
TDK-LambdaDFM1K1kW power line filter with medical safety certification
MTE CorporationPro-NetModular filter for industrial Ethernet applications
API TechnologiesPLF-300Military-grade filter for aerospace systems

7. Selection Guidelines

Key considerations: - Match voltage/current ratings with system requirements - Verify insertion loss curves at specific noise frequencies - Consider physical dimensions and cooling requirements - Ensure compliance with relevant standards (e.g., IEC 60939) - Evaluate environmental conditions (temperature, humidity, vibration) - Assess certification needs (CE, UL, MIL-STD)

8. Industry Trends

Market developments include: - Increasing demand for high-frequency filters (>10MHz) due to 5G/6G adoption - Miniaturization for EV and portable medical device applications - Integration with smart monitoring capabilities (IoT-enabled filters) - Growth in wide bandgap semiconductor compatible filters (SiC/GaN) - Stricter EMC regulations driving customized filter solutions - Market CAGR projected at 6.8% (2023-2030) according to industry reports