Thermal - Heat Sinks

Image Part Number Description / PDF Quantity Rfq
335214B00032G

335214B00032G

Aavid

BGA HEAT SINK

0

568300B00000

568300B00000

Aavid

BOARD LEVEL HEAT SINK

0

6232B-MTG

6232B-MTG

Aavid

BOARD LEVEL HEAT SINK

0

1130B

1130B

Aavid

THERMAL LINK

0

B-375-120-62G

B-375-120-62G

Aavid

HEAT SINK

0

529901B02100G

529901B02100G

Aavid

BOARD LEVEL HEAT SINK

0

6273B

6273B

Aavid

BOARD LEVEL HEAT SINK

0

6399B-P2G

6399B-P2G

Aavid

BOARD LEVEL HEAT SINK

0

591202B03700G

591202B03700G

Aavid

HEATSINK TO-220 CLIP-ON BLACK

138

7019BG

7019BG

Aavid

BOARD LEVEL HEAT SINK

0

533502B12552G

533502B12552G

Aavid

BOARD LEVEL HEATSINK W/THRM TAPE

229

6045BG

6045BG

Aavid

HEATSINK

0

574204B03300G

574204B03300G

Aavid

BOARD LEVEL HEAT SINK

0

529701B02100G

529701B02100G

Aavid

BOARD LEVEL HEAT SINK

0

532802B02500G

532802B02500G

Aavid

BOARD LEVEL HEAT SINK

0

6045B

6045B

Aavid

BOARD LEVEL HEAT SINK

0

530400B00100G

530400B00100G

Aavid

BOARD LEVEL HEAT SINK

0

342000F00000G

342000F00000G

Aavid

HEATSINK

0

581102B00000G

581102B00000G

Aavid

HEATSINK

0

581101B02500G

581101B02500G

Aavid

HEAT SINK

0

Thermal - Heat Sinks

1. Overview

Thermal heat sinks are passive or active cooling components designed to absorb and dissipate heat generated by electronic devices. They play a critical role in maintaining optimal operating temperatures for semiconductors, processors, and power modules. As modern electronics trend toward higher power density and miniaturization, effective thermal management through heat sinks has become essential for ensuring reliability, performance, and longevity of systems in applications ranging from consumer electronics to industrial machinery.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Passive Air-Cooled Heat SinksAluminum/copper fins without moving partsDesktop CPUs, LED lighting
Active Air-Cooled Heat SinksFans integrated with fin arraysGaming PCs, industrial control cabinets
Liquid-Cooled Heat SinksInternal channels for coolant circulationData center servers, EV battery packs
Heat Pipe Heat SinksVapor chamber technology for ultra-thin profilesSmartphones, aerospace electronics
Phase Change Heat SinksParaffin-based materials absorbing latent heatShort-duration high-load applications

3. Structure and Components

Typical heat sink structures include:

  • Finned Arrays: Corrugated metal surfaces (aluminum extrusions or folded copper sheets) for maximizing surface area
  • Base Plates: Machined or forged bases with micro-channel patterns for direct component contact
  • Thermal Interface Materials (TIMs): Graphite pads or phase-change materials between heat sink and component
  • Mounting Hardware: Spring-loaded pins or adhesive backers for secure installation
  • Protective Coatings: Anodized finishes or nickel plating for corrosion resistance

4. Key Technical Specifications

ParameterDescriptionImportance
Thermal Resistance0.5-10 C/W range depending on designDirectly impacts cooling efficiency
Material ConductivityAl: 180-240 W/m K | Cu: 390-400 W/m KDetermines heat transfer speed
Fin Density5-50 fins per inch (FPI)Affects airflow resistance and surface area
Operating Temperature-50 C to +250 C typical rangeDefines environmental suitability
Weight50g-10kg depending on applicationCritical for aerospace and mobile uses

5. Application Fields

  • Consumer Electronics: CPU/GPU cooling in computers, smartphone SoC thermal pads
  • Telecommunications: 5G base station power amplifiers, optical transceivers
  • Industrial: VFD motor controllers, welding equipment
  • Automotive: Electric vehicle (EV) battery packs, onboard chargers
  • Aerospace: Avionics cooling systems, satellite power modules

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Aavid (TE Connectivity)HiK Plate Heat SinksEmbedded heat pipes, thermal conductivity >400 W/m K
Cooler MasterHyper 212 RGB4 direct-contact heat pipes, 64 CFM fan
Delta ElectronicsCD7010 Liquid Cooler2-phase immersion cooling system
ThermaltakeFloe Riing RGB 360mm360mm radiator with RGB lighting
Boyd CorporationPhase Change PCM150150W thermal capacity for pulsed loads

7. Selection Guidelines

Key considerations include:

  • Calculate required thermal dissipation using Q = (Toperating - Tambient)/Rthermal
  • Verify dimensional compatibility with component footprint and clearance
  • Assess environmental conditions (humidity, vibration, corrosion potential)
  • Balance performance vs cost: Extruded aluminum offers best cost/performance ratio
  • Consider integration with existing cooling systems (e.g., existing fan airflow rates)

Case Study: For a 150W CPU with 70 C max operating temperature and 25 C ambient, required thermal resistance must be 0.3 C/W. Recommended solution: Copper base heat sink with 6 heat pipes and 120mm PWM fan.

8. Industry Trends

Emerging developments include:

  • Graphene-enhanced composites achieving 500+ W/m K conductivity
  • 3D-printed lattice structures reducing weight by 40% while maintaining performance
  • Smart heat sinks with embedded thermal sensors and adaptive fan control
  • Two-phase immersion cooling systems for data centers (up to 90% energy savings)
  • Microchannel liquid cooling for 5G millimeter-wave transmitters

Market forecasts predict a CAGR of 6.8% through 2030, driven by EV and 5G infrastructure demands.

RFQ BOM Call Skype Email
Top