AC Fans

Image Part Number Description / PDF Quantity Rfq
OA109AP-11-1TS

OA109AP-11-1TS

Orion Fans

FAN AXIAL 120X38MM 115VAC TERM

135

OA172SAN-22-1WB

OA172SAN-22-1WB

Orion Fans

FAN AXIAL 172X50.8MM 230VAC WIRE

0

OA4715-12TB

OA4715-12TB

Orion Fans

FAN AXIAL 120X38MM 120VAC TERM

723

OAB13391-22-1WB

OAB13391-22-1WB

Orion Fans

FAN IMP MTRZD 133X91MM 230VAC W/

13

OA9232EC-UR-1WB

OA9232EC-UR-1WB

Orion Fans

EC FAN 92X32MM 85-265VAC 56CFM

80

OA172EC-22-1TBIP68A

OA172EC-22-1TBIP68A

Orion Fans

FAN 172X150X51MM 230VAC IP68ATEX

18

OA2543AP-22-1TB1869K

OA2543AP-22-1TB1869K

Orion Fans

AC FAN, IP69K, 254X254X89MM, 230

5

OA280AP-22-1WB1868

OA280AP-22-1WB1868

Orion Fans

FAN 230AC 280X280X89MM IP68 WIRE

2

OA225LFGH221T

OA225LFGH221T

Orion Fans

FAN AXIAL 322.7X133.4MM 230VAC

3

OA254AN-11-2TB

OA254AN-11-2TB

Orion Fans

FAN AXIAL 254X89MM 115VAC TERM

0

OA109EC-UR-1WB

OA109EC-UR-1WB

Orion Fans

FAN EC 120X38MM 90-265VAC

107

OA172SAN-11-1TB

OA172SAN-11-1TB

Orion Fans

FAN AXIAL 172X50.8MM 115VAC TERM

5

OA254LFGS111TXC

OA254LFGS111TXC

Orion Fans

FAN TUBEAXIAL 317X317MM 115VAC

25

OAB908AN-11-3

OAB908AN-11-3

Orion Fans

FAN BLOWER 183X70MM 115VAC WIRE

0

OAB800AN-22-3B

OAB800AN-22-3B

Orion Fans

FAN BLOWER 125X39MM 230VAC WIRE

0

OA254LFGS111T

OA254LFGS111T

Orion Fans

FAN TUBEAXIAL 317X317MM 115VAC

0

OA254LFGH221TXC

OA254LFGH221TXC

Orion Fans

FAN AXIAL 322.7X322.7MM 230VAC

0

OAB908AN-22-3

OAB908AN-22-3

Orion Fans

FAN BLOWER 183X70MM 230VAC WIRE

0

OD9225-SPOT/DIN

OD9225-SPOT/DIN

Orion Fans

FAN AXIAL 120X32MM BALL 120VAC

0

OA254LFGS221TXC

OA254LFGS221TXC

Orion Fans

FAN TUBEAXIAL 317X317MM 230VAC

0

AC Fans

1. Overview

AC fans (Alternating Current Fans) are thermal management devices powered by AC electricity, primarily used to dissipate heat in electronic and mechanical systems. Operating on standard voltages (100-240V AC), they ensure optimal performance by maintaining safe temperature thresholds. Their importance has grown exponentially with advancements in high-power electronics, data centers, and industrial automation, where efficient thermal regulation prevents system failures and extends component lifespans.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Axial FansHigh airflow, low-pressure operation, compact designComputer cooling, HVAC systems
Centrifugal FansHigh-pressure output, compact radial airflowIndustrial ovens, dust extraction systems
Tube Axial FansIntermediate pressure, direct-drive efficiencyAir conditioning units, refrigeration systems
Vane Axial FansEnhanced aerodynamic stability, adjustable bladesPower plants, large-scale ventilation

3. Structure and Components

AC fans typically consist of: - Motor: Single-phase/three-phase induction motor with capacitor start - Blade Assembly: Plastic/metal blades optimized for aerodynamic efficiency - Bearing System: Ball bearings or sleeve bearings for durability - Frame: Metal/plastic housing with mounting brackets - Control Interface: Optional speed controllers or temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Voltage100-240V ACDetermines compatibility with power systems
Current0.1-5AAffects power consumption and heat generation
RPM600-3600Directly impacts airflow and noise levels
Airflow20-500 CFMMeasures cooling capacity
Noise Level20-60 dB(A)Critical for user comfort and workplace safety
MTBF20,000-100,000 hoursIndicates operational reliability

5. Application Fields

  • IT Infrastructure: Server racks, data center cooling
  • HVAC: Commercial air conditioning systems
  • Industrial: CNC machines, welding equipment
  • Medical: MRI scanners, laboratory equipment
  • Transportation: Electric vehicle charging stations, locomotive cooling

6. Leading Manufacturers and Products

ManufacturerProduct SeriesKey Specifications
ebm-papstAC GreenTechUp to 2,000W, EC motor integration
NidecMycom AC3-phase operation, 100,000 hours MTBF
Delta ElectronicsAC Axial SeriesVariable speed control, IP55 rating
Sanyo DenkiAC San AceHigh static pressure (300Pa), RoHS compliance

7. Selection Guidelines

Key considerations include: - Voltage/frequency compatibility with local power grids - Airflow requirements vs. static pressure demands - Noise constraints for end-user environments - Operating temperature range (-40 C to +70 C typical) - Expected operational lifespan and maintenance cycles - IP rating for dust/water protection (IP54 for industrial use) - Cost vs. energy efficiency trade-offs

Application Case Study

Data Center Cooling: A 500kW server farm required cooling solutions. Implementation of 24 ebm-papst AC GreenTech axial fans with 1,200 CFM airflow each achieved ISO Class 9 cleanroom standards while reducing energy consumption by 22% compared to conventional models.

Industry Trends Analysis

Future developments include: - Increased adoption of IoT-enabled "smart" fans with predictive maintenance - Development of oil-free ceramic bearings for medical applications - Integration with liquid cooling systems in hybrid thermal management - Growth in 400Hz AC fans for aerospace electronics - Regulatory push towards IE3+ efficiency standards compliance - Use of graphene-reinforced composite blades for weight reduction

RFQ BOM Call Skype Email